Harman Kardon AVR 345 EMC - CB Certificate ▷ View online
- Page 25 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N
A.10.2.1
Enclosure provides protection against splashing water
N
A.10.2.2 Humidity
treatment carried out for 7 days
N
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
No connection to TNV circuits
N
Complies with IEC 62151 clause 2
N
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this standard
modified in accordance with annex B of this standard
N
Complies with IEC 62151 clause 6
N
Complies with IEC 62151 clause 7
N
Complies with IEC 62151 annex A, B and C
N
IEC 62151 clause 4.1.1:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries shall be
as follow:
In Finland,
"Laite on liitettävä suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries shall be
as follow:
In Finland,
"Laite on liitettävä suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Class II apparatus
N
- Page 26 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
In OFF/Stand-by position,
the power consumption is less
than 2,3W.
the power consumption is less
than 2,3W.
P
Position of the functional switch (W) ...................... :
—
Operating conditions
Standby mode:
Un (V)
In (A)
Pn (W)
Pout (W)
207 0,009 1,4 —
230 0,011 1,8 —
253 0,018 2,3 —
Measured at maximum non-clipped output:
Un (V)
In (A)
Pn (W)
Pout (W)
253
5,26
1105
2 x 86,2 W
(F)
2 x 87,2 W
(S/B)
2 x 85,2 W
(S)
1 x 86,5 W
(C)
Measured at 1/8 of maximum non-clipped output:
Un (V)
In (A)
Pn (W)
Pout (W)
207 2,34
#) 2,17
374
#) 347
2 x 10,8 W
(F)
2 x 10,9 W
(S/B)
2 x 10,7 W
(S)
1 x 10,8 W
(C)
230 2,42
#) 2,27
427
#) 401
2 x 10,8 W
(F)
2 x 10,9 W
(S/B)
2 x 10,7 W
(S)
1 x 10,8 W
(C)
253 2,51
#) 2,35
485
#) 457
2 x 10,8 W
(F)
2 x 10,9 W
(S/B)
2 x 10,7 W
(S)
1 x 10,8 W
(C)
The input tests were conducted at 1 kHz sign wave input signal with 8 ohm load connected condition, and
than replaced the input signal to pink noise for heating and fault condition tests.
than replaced the input signal to pink noise for heating and fault condition tests.
The values followed #) mark in table above are measured “A” or “W” value, when replaced the input signal
from 1 kHz sign wave to pink noise.
from 1 kHz sign wave to pink noise.
Loudspeaker impedance (Ω) ....................
8 Ohms
—
Several loudspeaker systems
Right and Left for Front channels
Right and Left for SB/Multi channels
Right and Left for Surround channels
Only one for Center channel
Right and Left for SB/Multi channels
Right and Left for Surround channels
Only one for Center channel
—
Marking of loudspeaker terminals
SPEAKERS ( 8
Ω ): FRONT, SB/MULTI,
SURROUND, CENTER
—
- Page 27 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
Monitored point:
dT (K)
at 207V
dT (K)
at 253V
Limit dT (K)
*)
Main transformer core
45,8
59,9
95
Sub transformer core
33,4
48,9
85
PWB near D992
49,3
60,7
95
PWB near D991
68,6
80,6
95
PWB near IC90
42,8
62,6
95
PWB near Q803
33,5
48,3
95
D992 body
58,2
70,2
-
D991 body
76,9
88,7
-
IC90 body
44,7
65,0
-
Q803 body
52,2
74,4
-
R810 body
36,8
50,1
-
C902 E. capacitor body
29,7
40,6
85
°C
Fan body(on min heat-sink)
32,3
45,1
60
Fan body(on heat-sink side)
12,4
17,2
60
Main heat-sink
42,4
61,4
-
Appliance inlet body (inside)
24,6
33,1
60
Top enclosure above main transformer
8,1
15,0
40
Top enclosure above main heat-sink
19,8
24,6
40
Stand-by switch button (non-metallic)
1,2
2,3
50
*) Temperature rise limits for Singapore is 10K less
Winding temperature rise measurements
207V
253V
—
Ambient temperature t1 (
o
C) :
25,9
25,9
—
Ambient temperature t2 (
o
C) :
24,8
25,8
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit dT (K) Insulation
class
Main transf. pr. winding (207V)
1,821 2,251 62,6 95
B
Sub transf. pr. winding (207V)
1265 1439 36,9 85
E
Main transf. pr. winding (253V)
1,821 2,384 80,6 95
B
Sub transf. pr. winding (253V)
1265 1530 54,7 85
E
- Page 28 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
7.2
TABLE: softening temperature of thermoplastics
N
Temperature T of part
T - normal condi-
tions (
o
C)
T - fault condi-
tions (
o
C)
T softening
(
o
C)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 100
2
Between parts separated by double or reinforced insulation
> 100
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500V No
Between parts separated by double or reinforced insulation
3000V No
Click on the first or last page to see other AVR 345 service manuals if exist.