- Page 25 of 32 - 
 
 
www.nemko.com
 
Report No.  79765 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
 
A.10.2.1 
Enclosure provides protection against splashing water
 
A.10.2.2 Humidity 
treatment carried out for 7 days 
 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
 
 
Complies with IEC 62151 clause 1 
No connection to TNV circuits 
 
Complies with IEC 62151 clause 2 
 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard 
 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this standard
 
 
Complies with IEC 62151 clause 6  
 
 
Complies with IEC 62151 clause 7  
 
 
Complies with IEC 62151 annex A, B and C 
 
 
IEC 62151 clause 4.1.1: 
Add after the first paragraph: 
NOTE- In Finland, Norway and Sweden, class I 
equipment which is intended for connection to the 
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that the 
equipment must be connected to an earthed mains 
socket-outlet. 
The marking text in the applicable countries shall be 
as follow: 
In Finland,  
"Laite on liitettävä suojamaadoituskoskettimilla va 
rustettuunpistorasiaan” 
 
In Norway, 
"Apparatet må tilkoples jordet stikkontakt" 
 
In Sweden, 
"Apparaten skall anslutas till jordat uttag” 
Class II apparatus 
 
 
- Page 26 of 32 - 
 
 
www.nemko.com
 
Report No.  79765 
 
TRF No:  IEC/EN 60065F 
 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
In OFF/Stand-by position,  
the power consumption is less  
than 2,3W. 
 
Position of the functional switch (W)  ...................... :
 
— 
 
Operating conditions 
Standby mode: 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
207 0,009  1,4  — 
230 0,011  1,8  — 
253 0,018  2,3  — 
 
Measured at maximum non-clipped output:
 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
253 
5,26 
1105 
2 x 86,2 W 
(F) 
2 x 87,2 W 
(S/B) 
2 x 85,2 W 
(S) 
1 x 86,5 W 
(C) 
 
Measured at 1/8 of maximum non-clipped output: 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
207 2,34 
#) 2,17 
374 
#) 347 
2 x 10,8 W 
(F) 
2 x 10,9 W 
(S/B) 
2 x 10,7 W 
(S) 
1 x 10,8 W 
(C) 
230 2,42 
#) 2,27 
427 
#) 401 
2 x 10,8 W 
(F) 
2 x 10,9 W 
(S/B) 
2 x 10,7 W 
(S) 
1 x 10,8 W 
(C) 
253 2,51 
#) 2,35 
485 
#) 457 
2 x 10,8 W 
(F) 
2 x 10,9 W 
(S/B) 
2 x 10,7 W 
(S) 
1 x 10,8 W 
(C) 
The input tests were conducted at 1 kHz sign wave input signal with 8 ohm load connected condition, and 
than replaced the input signal to pink noise for heating and fault condition tests. 
The values followed #) mark in table above are measured “A” or “W” value, when replaced the input signal 
from 1 kHz sign wave to pink noise. 
 
         
 
Loudspeaker impedance (Ω) ....................
8 Ohms 
— 
         
 
Several loudspeaker systems 
Right and Left for Front channels 
Right and Left for SB/Multi channels 
Right and Left for Surround channels 
Only one for Center channel 
— 
         
 
Marking of loudspeaker terminals 
SPEAKERS ( 8
Ω ): FRONT, SB/MULTI, 
SURROUND, CENTER 
— 
 
 
- Page 27 of 32 - 
 
 
www.nemko.com
 
Report No.  79765 
 
TRF No:  IEC/EN 60065F 
 
 
Monitored point: 
 
 
dT (K)  
at 207V 
dT (K)  
at 253V 
Limit dT (K)
*) 
Main transformer core 
45,8 
59,9 
95 
Sub transformer core 
33,4 
48,9 
85 
PWB near D992 
49,3 
60,7 
95 
PWB near D991 
68,6 
80,6 
95 
PWB near IC90 
42,8 
62,6 
95 
PWB near Q803 
33,5 
48,3 
95 
D992 body 
58,2 
70,2 
D991 body 
76,9 
88,7 
IC90 body 
44,7 
65,0 
Q803 body 
52,2 
74,4 
R810 body 
36,8 
50,1 
C902 E. capacitor body 
29,7 
40,6 
85
°C 
Fan body(on min heat-sink) 
32,3 
45,1 
60 
Fan body(on heat-sink side) 
12,4 
17,2 
60 
Main heat-sink 
42,4 
61,4 
Appliance inlet body (inside) 
24,6 
33,1 
60 
Top enclosure above main transformer 
8,1 
15,0 
40 
Top enclosure above main heat-sink 
19,8 
24,6 
40 
Stand-by switch button (non-metallic) 
1,2 
2,3 
50 
*) Temperature rise limits for Singapore is 10K less 
         
 
Winding temperature rise measurements
 207V 
253V 
— 
         
 
Ambient temperature t1 (
o
C) :
 25,9 
25,9 
— 
         
 
Ambient temperature t2 (
o
C) :
 24,8 
25,8 
— 
Temperature rise dT of winding: 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT (K)  Insulation 
class 
Main transf. pr. winding (207V) 
1,821 2,251 62,6  95 
Sub transf. pr. winding (207V) 
1265 1439 36,9  85 
 
 
 
 
 
 
Main transf. pr. winding (253V) 
1,821 2,384 80,6  95 
Sub transf. pr. winding (253V) 
1265 1530 54,7  85 
 
 
- Page 28 of 32 - 
 
 
www.nemko.com
 
Report No.  79765 
 
TRF No:  IEC/EN 60065F 
 
 
7.2 
TABLE: softening temperature of thermoplastics 
 
Temperature T of part 
T - normal condi-
tions (
o
C) 
T - fault condi-
tions (
o
C) 
T softening 
(
o
C) 
 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
> 100 
Between parts separated by double or reinforced insulation 
> 100 
 
 
 
 
 
10.3 
TABLE: electric strength measurements 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected) 
1500V No 
Between parts separated by double or reinforced insulation 
3000V No 
 
 
 
Page of 51