Harman Kardon AVR 345 EMC - CB Certificate ▷ View online
- Page 21 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
16
EXTERNAL FLEXIBLE CORDS
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
Sheathed PVC cord
complying with IEC 60227
complying with IEC 60227
P
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
Class II apparatus
N
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
The cord is 0,75mm², within the
current rating
current rating
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
No interconnecting cables
comprising hazardous live
conductors.
comprising hazardous live
conductors.
N
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
Cord complying with 16.1.
N
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
Cords have adequate cross-
sectional areas to avoid
temperature rise under normal
and fault conditions.
sectional areas to avoid
temperature rise under normal
and fault conditions.
P
16.5
Adequate strain relief on external flexible cords
Appliance inlet provided
N
Not possible to push cord back into equipment
N
Strain relief device unlikely to damage flexible cord
N
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
Class II apparatus
N
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
Appliance inlet provided
N
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
fitted with detachable cord set with appliance inlet
to IEC 60320-1
The apparatus is not a
transportable musical
instrument and amplifier
transportable musical
instrument and amplifier
N
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
The apparatus is not a
transportable musical
instrument and amplifier
transportable musical
instrument and amplifier
N
- Page 22 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
17 ELECTRICAL
CONNECTIONS
AND MECHANICAL FIXINGS
17.1
Torque test to table 20:
Screws fixing chassis to the
main enclosure tested.
main enclosure tested.
P
- screws into metal: 5 times
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
- screws into non-metallic material: 10 times
N
17.2
Correct introduction into female threads in non-
metallic material
metallic material
No female threads in non-
metallic materials
metallic materials
N
17.3
Cover fixing screws: captive
Captivity not necessary
P
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
Tested with screw with
10 times diameter.
10 times diameter.
P
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
Loosening is sufficiently
prevented
prevented
P
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
No contact pressure
transmitted through insulating
material.
transmitted through insulating
material.
P
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
Appliance inlet provided
N
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
No cover fixing devices other
than screws
than screws
N
17.8
Fixing devices for detachable legs or stands
provided
provided
No detachable provided
N
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
Connections complies,
checked by inspection
checked by inspection
P
- Page 23 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965:
No CRT in the equipment
N
Picture tube separately approved to 18.1 ...............
N
18.1
Picture tubes > 16 cm intrinsically protected
N
Non-intrinsically protected tubes > 16 cm used with
protective screen
protective screen
N
18.2
Intrinsically protected tubes: tests on 12 samples
N
18.2.1
Samples subject to ageing: 6
N
18.2.2
Samples subject to implosion test: 6
N
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N
18.3
Non-intrinsically protected tubes tested to 18.3
N
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg ................. :
Weight: 14 kg
⎯
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
No
N
19.1
Test on a plane, inclined at 10
o
to the horizontal
Tested on a plane inclined at
an angle of 10°
an angle of 10°
P
19.2
100 N force applied vertically downwards
100N force have no influence
on the stability
on the stability
P
19.3
Apparatus mass > 25 kg or height > 1 M or
supplied with cart or stand
supplied with cart or stand
< 25 kg, < 1M
N
19.4
Edges or corners not hazardous
There is no hazardous edges
or corners when the
apparatus is operating in
normal position
or corners when the
apparatus is operating in
normal position
P
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
maximum dimension > 450 mm, pass the test of
19.5.1
No glass surface
N
19.6
Wall or ceiling mountings adequate
Not intended for wall or ceiling
mounting
mounting
N
- Page 24 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
N
b) Exemption for small components as defined in
20.1
20.1
PCB is of flammability class
V-1 and exception is made for
small componets.
V-1 and exception is made for
small componets.
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components comply
with flammability requirements
in clause 14.
with flammability requirements
in clause 14.
P
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
No wires working at voltages
> 4kV or leaving an internal
fire enclosure
> 4kV or leaving an internal
fire enclosure
N
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
All PCB is of base material
with flammability category V-1
or better. See appended table
with flammability category V-1
or better. See appended table
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
No voltage exceeding 400V
(peak) a.c. or d.c.
(peak) a.c. or d.c.
N
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
No such components
N
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
No such components
N
20.2 Fire
enclosure
N
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No voltages exceeding 4kV,
no fire enclosure requirement
no fire enclosure requirement
N
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
No internal fire enclosure.
N
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
No internal fire enclosure.
N