Harman Kardon AVR 345 EMC - CB Certificate ▷ View online
- Page 13 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
No hazardous secondary
voltages
voltages
N
13.4 Creepage
distances
CTI > 100
See attachment, Table to
EN/IEC 60065 7
See attachment, Table to
EN/IEC 60065 7
th
edition
P
Creepage distances greater than table 11 minima
Not applicable
N
13.5 Printed
boards
N
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
No type B coated PWB
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
Jointed insulation not applied
N
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
No enclosed, enveloped or
hermetically sealed parts
hermetically sealed parts
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
No parts filled with insulating
compound
compound
N
14 COMPONENTS
14.1 Resistors
N
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
Not used
N
b) Resistors separately approved .......................... :
N
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes,
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. :
No Y capacitors
N
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. :
C904 is Certified X capacitor
by IEC 60384-14, 2
by IEC 60384-14, 2
nd
edition
P
- Page 14 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
No such capacitors
N
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N
Shielded by a barrier to V-0 or metal ..................... :
N
14.3
Inductors and windings
See below.
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
Transformers evaluated
according to 14.3.3, 14.3.4
and 14.3.5
according to 14.3.3, 14.3.4
and 14.3.5
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
Adequate marking applied.
- Type no. and,
-.Manufacturer’s ID
- Type no. and,
-.Manufacturer’s ID
P
Transformers and inductors separately approved . :
No
N
14.3.2 General
Isolating transformer
P
14.3.3 Constructional
requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between primary and secondary
windings according to clause 8.8.
between primary and secondary
windings according to clause 8.8.
P
Coil formers and partition walls > 0,4 mm
The bobbin fulfils the requireme
nt
of reinforced insulation; bobbin
thickness > 0,4 mm.
nt
of reinforced insulation; bobbin
thickness > 0,4 mm.
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II apparatus. No such
transformer used.
transformer used.
N
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts.
between hazardous live
windings and accessible
conductive parts.
P
- Page 15 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Coil formers and partition walls > 0,4 mm
The bobbin fulfils the requireme
nt
of reinforced insulation; bobbin
thickness > 0,4 mm.
nt
of reinforced insulation; bobbin
thickness > 0,4 mm.
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Windings of Class II
construction used.
construction used.
N
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N
14.4
High voltage components
No high voltage components
N
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N
Component meets category V-1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N
14.5 Protective
devices
P
Protective devices used within their ratings
Thermal links and fuses
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Certified protective devices
applied. See appended table,
list of critical components.
applied. See appended table,
list of critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved
None
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
The thermal links in main and
sub transformers, separately
approved, see appended table,
list of critical components.
sub transformers, separately
approved, see appended table,
list of critical components.
P
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
No such thermal device
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are certified according
to IEC60127
to IEC60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
Correct marking applied close
to the fuse;
F901: T6.3A L 250V,
F902: T2.5A L 250V
to the fuse;
F901: T6.3A L 250V,
F902: T2.5A L 250V
P
- Page 16 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.5.2.3
Not possible to connect fuses in parallel ............... :
No fuse holder so designed that
fuse-links can be connected in
parallel
fuse-links can be connected in
parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
None
N
PTC-S devices (15 W) category V-1 or better
None
N
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
No such components
N
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
Yes,
Mains switch and relay provided.
Certified acc. to IEC61058-1.
- Mains switch, certified by VDE,
-
Mains relay, certified by SEMKO.
See appended table, list of
critical components.
Mains switch and relay provided.
Certified acc. to IEC61058-1.
- Mains switch, certified by VDE,
-
Mains relay, certified by SEMKO.
See appended table, list of
critical components.
P
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
Separately approved switch
and relay.
and relay.
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
Separately approved switch
and relay.
and relay.
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved switch
and relay.
and relay.
N