DOWNLOAD Harman Kardon AVR 171 (serv.man5) Service Manual ↓ Size: 6.35 MB | Pages: 108 in PDF or view online for FREE

Model
AVR 171 (serv.man5)
Pages
108
Size
6.35 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-171-sm5.pdf
Date

Harman Kardon AVR 171 (serv.man5) EMC - CB Certificate ▷ View online

Page 8 of 16 
Report No.: 232174 
 
ATTACHMENT 4 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Zx.4.3 Wireless listening devices 
In wireless mode: 
with any playing and transmitting device playing 
  the fixed programme simulation noise described 
  in EN 50332-1; and 
respecting the wireless transmission standards, 
  where an air interface standard exists that 
specifies the equivalent acoustic level; and 
with volume and sound settings in the listening 
  device (for example built-in volume level control, 
  additional sound feature like equalization, etc.) 
  set to the combination of positions that maximize 
  the measured acoustic output for the above-
  mentioned programme simulation noise, the 
  acoustic output L
Aeq,T 
of the listening device shall 
 be ≤ 100 dBA. 
 
NOTE An example of a wireless listening device is a Bluetooth 
headphone. 
No portable sound system. 
N/A 
Zx.5 Measurement methods 
Measurements shall be made in accordance with 
EN 50332-1 or EN 50332-2 as applicable. 
Unless stated otherwise, the time interval T shall be 
30 s. 
 
NOTE Test method for wireless equipment provided without 
listening device should be defined.
 
 
N/A 
Page 9 of 16 
Report No.: 232174 
 
ATTACHMENT 4 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
6.1 
(A11:2008) 
Replace the entire subclause in EN 60065:2002 
and EN 60065:2002/A1:2006 by: 
Ionizing radiation 
Apparatus including a potential source of ionizing 
radiation shall be so constructed that personal 
protection against ionizing radiation is provided 
under normal operating conditions and under fault 
conditions. 
Compliance is checked by measurement under the 
following conditions

In addition to the normal operating conditions, all 
controls adjustable from the outside BY HAND, by 
any object such as a tool or a coin, and those 
internal adjustments or pre-sets which are not 
locked in a reliable manner, are adjusted so as to 
give maximum radiation whilst maintaining an 
intelligible picture for 1 h, at the end of which the 
measurement is made. 
NOTE 1 Soldered joints and paint lockings are 
examples of adequate locking. 
The dose-rate is determined by means of a 
radiation monitor with an effective area of 10 cm², 
at any point 10 cm from the outer surface of the 
apparatus. 
Moreover, the measurement shall be made under 
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is 
maintained for 1 h, at the end of which the 
measurement is made. 
The dose-rate shall not exceed 1μSv/h (0,1 mR/h) 
taking account of the background level. 
NOTE 2 These values appear in Directive 
96/29/Euratom of 13th May 1996.  
A picture is considered to be intelligible if the 
following conditions are met
a scanning amplitude of at least 70 % of the 
usable screen width; 
a minimum luminance of 50 cd/m² with locked 
blank raster provided by a test generator; 
- a horizontal resolution corresponding to at least 
1,5 MHz in the centre, with a similar vertical 
degradation; 
not more than one flashover per 5 min. 
No ionizing radiation. 
N/A 
Page 10 of 16 
Report No.: 232174 
 
ATTACHMENT 4 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Z1 
(A11:2008) 
 
Add the following new clause after Clause 20: 
Z1 Resistance to candle flame ignition 
A television set shall be so designed that the 
likelihood of ignition and the spread of fire caused 
by a candle flame is reduced. 
NOTE 1 An apparatus with a viewing screen is not 
regarded to be a television set if it is declared not to 
be so by the manufacturer. 
This requirement does not apply to the display 
screen of rear projection TV’s. 
NOTE 2 This exemption has been allowed because 
this technology is falling out of use and it is 
expected that within a few years it will no longer 
exist. This exemption will not be extended to other 
technologies. 
NOTE 3 The frame around the screen is not 
exempted from the requirements. 
Wood and WOOD-BASED MATERIAL with a 
thickness of at least 6 mm is considered to fulfil the 
V-1 requirement when applying CLC/TS 62441. 
Compliance is checked according to CLC/TS 
62441. 
NOTE 4 The term vertical, as used in the first dash 
of clause 5.2 of CLC/TS 62441, does not mean a 
perfectly vertical position. It should be interpreted 
as any surface that can be touched by the flame of 
a candle of 150 mm height and 20mm diameter 
while the candle is still touching the supporting 
surface. A typical candle used in the home is 
assumed to be 20 mm diameter. 
NOTE 5 It is expected that CLC/TS 62441 will in 
the future be replaced by a standard, at which time 
that standard will become applicable, subject to a 
vote by National Committees at the time. 
No television set. 
N/A 
General 13.3.1 
Delete note 4. 
14  
Delete note 4 and note 5. 
15.1.1 
Delete notes 1 and 2. 
15.2 
Delete note 2. 
16.1 
Delete note 1. 
16.2 
Delete the note. 
20 
Delete note 2. 
Annex B  
Replace note 1 by: In the CENELEC countries listed in IEC 62151, 
 
special national conditions apply. 
Annex G  
Delete the note. 
Annex J.2 
Delete the notes of Table J.1. 
Annex N  
Add after the introduction: For ROUTINE TEST reference is made to 
 
EN 50333. (Replaced by EN 50514) 
— 
Page 11 of 16 
Report No.: 232174 
 
ATTACHMENT 4 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
General 
(A2:2010) 
In IEC 60065:2001/A2 
Delete 
all the “country” notes according to the following list: 
5.3  
Note 
5.4.1   Note 
20  
Note 
For special national conditions, see Annex ZB. 
— 
Bibliograph
Additional EN standards. 
— 
 
ZA 
Normative references to international publications 
with their corresponding European publications 
— 
 
ZB 
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN) 
 
2.6.1 
 
DK: The following is added
Certain types of CLASS I apparatus, see 15.1.1, 
may be provided with a plug not establishing 
earthing continuity when inserted in Danish socket-
outlets 
Justification: Heavy Current Regulations, Section 
107. 
Class II apparatus. 
N/A 
3.Z1 
(A2:2010) 
Denmark 
Add 
to the end of the subclause 
Due to many existing installations where the 
socket-outlets can be protected with 
fuses with higher rating than the rating of the 
socket-outlets the protection for 
pluggable equipment type A shall be an integral 
part of the equipment. 
Justification
In Denmark an existing 13 A socket outlet can be 
protected by a 20 A fuse. 
No socket-outlets. 
N/A 
Page of 108
Display

Click on the first or last page to see other AVR 171 (serv.man5) service manuals if exist.