Harman Kardon AVR 171 (serv.man5) EMC - CB Certificate ▷ View online
Page 7 of 7
Report No.: 232174
ATTACHMENT 3
Photos
TRF No. IEC60065K
< TF93 transformer >
Page 1 of 16
Report No.: 232174
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
ATTACHMENT TO TEST REPORT IEC 60065
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Audio, video and similar electronic apparatus – Safety requirements
Differences according to ............... : EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
Attachment Form No. ..................... : EU_GD_IEC60065K_II
Attachment Originator ................... : Intertek Semko AB
Master Attachment ......................... : Date (2011-08)
Copyright © 2010 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
(IECEE), Geneva, Switzerland. All rights reserved.
IEC 60065, GROUP DIFFERENCES (CENELEC common modifications (EN))
Clause
Requirement + Test
Result - Remark
Verdict
Contents Add the following annexes:
Annex ZA (normative) Other international publications quoted in this standard with
the references of the relevant European publications (See the CB Bulletin)
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
the references of the relevant European publications (See the CB Bulletin)
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
P
Definition
2.2.Z1
(A11:2008)
2.2.Z1
(A11:2008)
Add after the definition 2.2.12 the following new
definition:
PORTABLE SOUND SYSTEM
small battery powered audio equipment:
whose prime purpose is to listen to recorded or
definition:
PORTABLE SOUND SYSTEM
small battery powered audio equipment:
whose prime purpose is to listen to recorded or
broadcasted sound; and
that uses headphones or earphones that can
be worn in or on or around the ears; and
that allows the user to walk around
NOTE Examples are mini-disc or CD players, MP3
audio players or similar equipment.
NOTE Examples are mini-disc or CD players, MP3
audio players or similar equipment.
No portable sound system.
N/A
2.2
(A12:2011)
(A12:2011)
In EN 60065:2002/A11:2008
Delete the definition 2.2.Z1
Noted.
—
Page 2 of 16
Report No.: 232174
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
3.1
Add the following indent at the end of the list
-
-
Exposure to excessive sound pressures from
headphones or earphones
headphones or earphones
NOTE A new method of measurement is described
in EN 50332-1, Sound system equipment:
Headphones and earphones associated with
portable audio equipment
– Maximum sound pressure level measurement
methodology and limit considerations – Part 1:
General method for ”one package equipment”, and
in EN 50332-2, Sound system equipment:
Headphones and earphones associated with
portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 2: Guidelines to associate
sets with headphones coming from different
manufacturers.
in EN 50332-1, Sound system equipment:
Headphones and earphones associated with
portable audio equipment
– Maximum sound pressure level measurement
methodology and limit considerations – Part 1:
General method for ”one package equipment”, and
in EN 50332-2, Sound system equipment:
Headphones and earphones associated with
portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 2: Guidelines to associate
sets with headphones coming from different
manufacturers.
No portable sound system.
N/A
3.1
(A12:2011)
(A12:2011)
In EN 60065:2002
Delete the addition of indent regarding sound
pressure excessive
Delete the addition of indent regarding sound
pressure excessive
—
3.Z1
(A2:2010)
(A2:2010)
After 3.2 add a new clause 3.Z1:
To protect against excessive current, short-circuits
and earth faults in MAINS, protective devices shall
be included either as integral parts of the
equipment or as parts of the building installation,
subject to the following, a), b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the requirements
of 11 shall be included as parts of the equipment;
b) for components in series or parallel with the
mains input to the equipment such as the supply
cord, appliance coupler, r.f.i. filter and switch, short-
circuit and earth fault protection may be provided
by protective devices in the building installation;
c) it is permitted for equipment supplied via an
industrial mains plug or for PERMANENTLY
CONNECTED APPARATUS, to rely on dedicated
over current and short-circuit protection in the
building installation, provided that the means of
protection, e.g. fuses or circuit breakers, is fully
specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for not via an industrial mains
plug or for PERMANENTLY CONNECTED
APPARATUS the building installation shall be
regarded
To protect against excessive current, short-circuits
and earth faults in MAINS, protective devices shall
be included either as integral parts of the
equipment or as parts of the building installation,
subject to the following, a), b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the requirements
of 11 shall be included as parts of the equipment;
b) for components in series or parallel with the
mains input to the equipment such as the supply
cord, appliance coupler, r.f.i. filter and switch, short-
circuit and earth fault protection may be provided
by protective devices in the building installation;
c) it is permitted for equipment supplied via an
industrial mains plug or for PERMANENTLY
CONNECTED APPARATUS, to rely on dedicated
over current and short-circuit protection in the
building installation, provided that the means of
protection, e.g. fuses or circuit breakers, is fully
specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for not via an industrial mains
plug or for PERMANENTLY CONNECTED
APPARATUS the building installation shall be
regarded
Integral parts of the
equipment (over current
protective device (fuse)
provided)
equipment (over current
protective device (fuse)
provided)
P
Page 3 of 16
Report No.: 232174
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
4.1.1
Replace the text of the note by: NOTE For
ROUTINE TEST reference is made to EN 50514.
ROUTINE TEST reference is made to EN 50514.
Considered
P
5.4.1
za)
(A11:2008)
za)
(A11:2008)
Modify indent za) as follows:
za) For a PORTABLE SOUND SYSTEM, a warning
that excessive sound pressure from earphones and
headphones can cause hearing loss.
za) For a PORTABLE SOUND SYSTEM, a warning
that excessive sound pressure from earphones and
headphones can cause hearing loss.
No portable sound system.
N/A
5.4.1
(A12:2011)
(A12:2011)
In EN 60065:2002/A1:2006 and EN
60065;2002/A11:2008
Delete the modification in indent za)
Add the following clause and annex to the excisting
standard and amendments
60065;2002/A11:2008
Delete the modification in indent za)
Add the following clause and annex to the excisting
standard and amendments
No portable sound system.
N/A
Click on the first or last page to see other AVR 171 (serv.man5) service manuals if exist.