Report No.: 232174 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Applicable to portable/wall socket-outlet and portable cable reel 
20 Portable/wall 
socket-outlet 
and portable 
cable reel 
a) If residual current device (RCD) is 
incorporated, its tripping current must 
be less than 30mA and operating 
time must be less than 0.1 second 
and testing to sub-clauses 9.9.2.1, 
9.9.2.2, 9.9.2.3 and 9.16 of SS 97: 
Part 1: 2000 are required. 
b) The shutters screening the current-
carrying socket contacts shall not be 
opened by the insertion of any 
corresponding SINGLE pin of the 
plug into any current-carrying socket 
aperture. 
No portable/wall socket- 
outlet and portable cable 
reel. 
N/A 
21 
Wall switched  
socket-outlet 
(2 x single  
socket-outlet) 
Single socket-outlet with 2-gang  
faceplate/frame must be fulfilled 
with the test requirements as 2-gang 
socket-outlet. 
 
N/A 
22 
Remote  
controlled 
portable/wall  
portable 
socket-outlet 
Remote controlled portable/wall  
socket-outlet shall not be 
allowed for registration. 
 
N/A 
Applicable to roaster 
23 
Roaster 
A metal ring (Appendix U) must be 
provided to prevent the roaster from 
falling off in case the glass bowl 
shattered. 
No roaster 
N/A 
Applicable to Residual Current Circuit Breaker (RCCB) 
33 RCCB 
Registration of RCCB is limited to 30 
mA sensitivity and the operating time 
must be less than 0.1 second. 
Electronic RCCB will not be accepted 
for registration. 
No residual current circuit 
breaker 
N/A 
Applicable to electric instantaneous and storage water heater 
34 
Instantaneous 
electric water 
heater and mains 
pressure electric 
storage water 
heater 
Heating elements used must not 
be of the "bare-element" type. 
No electric instantaneous  
and storage water heater 
N/A 
Page 5 of 5 
Report No.: 232174 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
35 
Water heater 
incorporated with 
residual current 
device(RCD) 
Testing to sub-clauses 9.9.2.1, 
9.9.2.2, 9.9.2.3 and 9.16 of SS 97: 
Part 1: 2000 are required. 
 N/A 
Applicable to multiway adaptor 
36 Multiway 
adaptor 
with 3-pin socket-
outlets or 
combination of 3-
pin and 2-pin 
socket-outlets 
a) The socket contacts of the 
adaptor shall only accept 13A 3-pin 
mains plug complying with SS 145 
and/or 2.5A 2-pin mains plug 
complying with EN 50075. 
b) The shutters screening the 
current-carrying socket contacts 
shall not be opened by the 
insertion of any corresponding 
SINGLE pin of the plug into any 
current-carrying socket aperture. 
c) A barrier or other acceptable 
means shall be provided on the 
engagement surface of the 2.5A 2-
pin socket-outlet of the adaptor to 
PREVENT entry of any types of 2-
pin mains plugs except those 
complying with EN 50075. (note: 
shutters cannot be regarded as 
barriers

d) Adaptor incorporates with switch 
would require additional test to 
sub-clauses 13.11, 17.1.3 and 
18.1.3 of SS 145: Part 2: 1997. 
No multiway adaptor 
N/A 
Applicable to plasma/LCD display monitor 
37 Plasma/LCD 
display monitor 
with TV tuner 
Plasma/LCD display monitor tested 
to IEC 60950 would require 
additional test to clauses 9 (related 
to antenna only), 10.1, 10.2, 10.3 
and 12.5 of IEC 60065. 
No Plasma/LCD display 
monitor 
N/A 
 
 
 
Page 1 of 6 
Report No.: 232174 
 
ATTACHMENT 6 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
CHINA NATIONAL DIFFERENCES 
Test results according to Online CB BULLETIN (Last modification date of 2012-06-06) 
Differences according .................... :  IEC 60065, 7th edition (2001)+Amendment 1 (2005) 
Corresponding National Standard  GB 8898-2011 
No. 
Requirement – Test 
Result - Remark 
Verdict 
1.1.3 
Amended the first paragraph: 
This standard applies to apparatus intended to be 
used basically at altitudes not exceeding 5 000 m, 
dry climate at warm temperate zone or tropical 
climates. 
Noted 
 
 
The fourth paragraph replaced by following: 
For apparatus intended to be used in vehicles, 
ships or aircraft, or at altitudes exceeding  
5 000m, additional requirements may be necessary.
The apparatus intended to be 
operated at altitudes up to  
2 000m.
 
N/A 
At the end of the first paragraph ,added following: 
For apparatus intended to be used at altitude not 
exceeding 2000m, a warning label containing the 
following or a similar appropriate wording or a 
symbol as in annex R(see following) shall fixed to 
the equipment at readily visible place. 
"Only used at altitude not exceeding 2000m."  
 
If only symbol used, the explanation of the symbol 
shall be contained in the instruction manual. 
  
The apparatus intended to  
be operated at altitudes up to  
2 000m, and a
ppropriate  
wording provided as follows, 
 
See copy of marking plate. 
 
Page 2 of 6 
Report No.: 232174 
 
ATTACHMENT 6 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
For apparatus intended to be used in not-tropical 
climate regions, a warning label containing the 
following or a similar appropriate wording or a 
symbol as in annex R shall fixed to the equipment 
at readily visible place. 
"Only used in not-tropical climate regions." 
 
If only symbol used, the explanation of the symbol 
shall be contained in the instruction manual. 
 
The statements above shall be given in a language 
acceptable to the regions where the apparatus is 
intended to be used. 
The apparatus intended to  
be used in not tropical climate 
regions, and a
ppropriate  
wording provided as follows 
 
See copy of marking plate. 
5.1 e) 
After the last paragraph, added: 
…….For single rated voltage, “220 V” or three-
phase “380V” shall be marked only. For a rating 
range, 220 V or three-phase 380V shall be covered. 
For multiple rated voltages, one of them shall be 
220 V or three-phase 380V and which default 
setting from manufacture shall be 220 V or three-
phase 380V as well. 
Covered 
5.1 f) 
After the first sentence, Added: 
……for Rated MAINS frequency or frequency range 
shall be 50Hz or covered 50Hz. 
Rated MAINS frequency of 
50Hz covered. 
5.4 
Replaced the second sentence of the first 
paragraph: 
This information shall be given in normative 
Chinese. 
Adequate instruction supplied 
by Chinese manual with the 
apparatus.
 
5.4.1i) 
Added new paragraph i),after the h) paragraph: 
i) For apparatus incorporating antenna coaxial 
sockets witch is non-separated with CATV network, 
a warning wording or a similar shall be given in the 
instructions manual:  
“The CATV network connecting to this apparatus 
shall separate from protective earth, otherwise it 
may cause fire or other hazard.” 
No CDS 