DOWNLOAD Harman Kardon AVR 170 Service Manual ↓ Size: 4.96 MB | Pages: 85 in PDF or view online for FREE

Model
AVR 170
Pages
85
Size
4.96 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-170.pdf
Date

Harman Kardon AVR 170 EMC - CB Certificate ▷ View online

 
Page 12 of 15 
Report No.: 209462 
 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
       
TRF No. IEC60065K 
5.4.1 
(A11:2008

 
Norway and Sweden  
To the end of 5.4.1 (after the compliance 
statement) the following is added:  
The screen of the cable distribution system is 
normally not earthed at the entrance of the building 
and there is normally no equipotential bonding 
system within the building. Therefore the protective 
earthing of the building installation need to be 
isolated from the screen of a cable distribution 
system.  
It is however accepted to provide the insulation 
external to the equipment by an adapter or an 
interconnection cable with galvanic isolator, which 
may be provided by e.g. a retailer.  
The user manual shall then have the following or 
similar information in Norwegian and Swedish 
language respectively, depending on in what 
country the equipment is intended to be used in:  
“Equipment connected to the protective earthing of 
the building installation through the mains 
connection or through other equipment with a 
connection to protective earthing – and to a cable 
distribution system using coaxial cable, may in 
some circumstances create a fire hazard. 
Connection to a cable distribution system has 
therefore to be provided through a device providing 
electrical isolation below a certain frequency range 
(galvanic isolator, see EN 60728-11)”  
NOTE In Norway, due to regulation for installations of cable 
distribution systems, and in Sweden, a galvanic isolator shall 
provide electrical insulation below 5 MHz. The insulation shall 
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, 
for 1 min.  
Translation to Norwegian (the Swedish text will also 
be accepted in Norway):  
“Utstyr som er koplet til beskyttelsesjord via 
nettplugg og/eller via annet jordtilkoplet utstyr – og 
er tilkoplet et kabel-TV nett, kan forårsake 
brannfare. For å unngå dette skal det ved tilkopling 
av utstyret til kabel-TV nettet installeres en 
galvanisk isolator mellom utstyret og kabel-TV 
nettet.”  
Translation to Swedish:  
”Utrustning som är kopplad till skyddsjord via jordat 
vägguttag och/eller via annan utrustning och 
samtidigt är kopplad till kabel-TV nät kan i vissa fall 
medföra risk för brand.  
Főr att undvika detta skall vid anslutning av 
utrustningen till kabel-TV nät galvanisk isolator 
finnas mellan utrustningen och kabel-TV nätet.” 
Class II apparatus. 
N/A 
 
Page 13 of 15 
Report No.: 209462 
 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
       
TRF No. IEC60065K 
13.3.1 
 
NO: To the second paragraph the following is 
added: 
In Norway, due to the IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230 V in case of a single earth fault. 
Justification: Based on a use in Norway of an IT 
power distribution system where the neutral is not 
provided. 
Noted. 
N/A 
15.1.1 
(A11:2008

 
Denmark  
The text of the Danish SNC in EN 60065:2002 has 
been modified as follows:  
To the first paragraph the following is added:  
In Denmark, supply cords of single-phase 
appliances having a rated current not exceeding 13 
A shall be provided with a plug according to the 
Heavy Current Regulations Section 107-2-D1.  
Appliances of CLASS I provided with socket-outlets 
with earth contact or which are intended to be used 
in locations where protection against indirect 
contact is required according to the wiring rules 
shall be provided with a plug in accordance with the 
Heavy Current Regulations, Section 107-2-D1 
standard sheet DK 2-1a.  
To the second paragraph the following is added:  
Socket outlets intended for providing power to 
CLASS II apparatus with a rated current of 2,5 A 
shall be in accordance with the Heavy Current 
Regulation, Section 107-2-D1 standard sheet DKA 
1-4a.  
Other current ratings socket outlets shall be in 
compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DKA 1-3a or DKA 
1-3b.  
To the third paragraph the following is added:  
Mains socket-outlets with earthing contact shall be 
in compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a 
or DK 1-7a.  
Justification: Heavy Current Regulations, Section 
107-2-D1 
No socket-outlets. 
N/A 
15.1.1 
IE: Apparatus which is fitted with a flexible cable or 
cord shall be provided with a 13 A plug in 
accordance with Statutory Instrument 525:97, “13 A  
Plugs and Conversion Adapters for Domestic Use 
Regulations:1997. 
Justification: SI 525: 1997
 
Not provided. 
See summary of testing. 
N/A 
 
Page 14 of 15 
Report No.: 209462 
 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
       
TRF No. IEC60065K 
15.1.1 
 
NO: Mains socket-outlets mounted on CLASS II 
apparatus shall comply with the specifications 
given in CEE Publ. 7 as far as a applicable, with 
the following amendments: 
§ 8 Dimensions 
a 2.5 A 250 V two-pole socket-outlets for electronic 
apparatus shall comply with the enclosed Standard 
Sheet I. 
 
§ 24 Mechanical strength 
A 2,5 A 250 V socket-outlets for CLASS II 
electronic apparatus are tested as specified in 
12.1.3 of EN 60065. Also the protecting rim shall be 
tested 
Justification: Act of 24 May 1929 relating to 
supervision of electrical installation (TEA 1929/FEL 
1998). 
No mains socket-outlets 
N/A 
15.1.1  
 
 
UK: Apparatus which is fitted with a flexible cable 
or cord and is designed to be connected to a mains 
socket conforming to BS 1363 by means of that 
flexible cable or cord and plug shall be fitted with 
a ”standard plug” in accordance with Statutory 
Instrument 1768: 1994: The Plugs and Sockets etc. 
(Safety) Regulations 1994, unless exempted by 
those Regulations. 
NOTE ”Standard plug” is defined in SI 1768:1994 
and essentially means an approved plug 
conforming to BS 1363 or an approved conversion 
plug. 
Justification: SI 1768: 1994 
Not provided. 
See summary of testing. 
N/A 
 
Page 15 of 15 
Report No.: 209462 
 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
       
TRF No. IEC60065K 
J.2 
NO: After Table J.1 the following is added: 
In Norway, due to the IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230 V in case of a single earth fault. 
Justification: Based on a use in Norway of an IT 
power distribution system where the neutral is not 
provided. 
Noted. 
N/A 
 
ZC 
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN) 
 
5.1 
 
IT: Additional markings on the outside of the TV 
receiver in Italian language 
Not CRT TV set. 
N/A 
 
IT:User instructions in Italian language including a 
conformity declaration 
 
N/A 
 
IT: Certification number on the back cover 
 
N/A 
6.1 
 
DE: The following requirement applies: 
For the operation of any cathode ray tube intended 
for the display of visual images operating at an 
acceleration voltage exceeding 40 kV, authorization 
is required, or application of type approval 
(Bauartzulassung) and marking. 
Justification: German ministerial decree against 
ionizing radiation (Röntgenverordnung), in force 
since 2002-07-01, implementing the European 
Directive 96/29/EURATOM.  
NOTE Contact address: 
Physikalisch-Technische Bundesanstalt, 
Bundesallee 100, D-38116 Braunschweig, Tel.: 
Int+49-531-592-6320, Internet: http://www.ptb.de 
No CRT used in the 
equipment. 
N/A 
14 
 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
Justification: Ordinance (1990:944) on Prohibition 
in Connection with handling. Importation and 
exportation of Chemical Products (Certain Cases) 
No such switches 
N/A 
 
 
Page of 85
Display

Click on the first or last page to see other AVR 170 service manuals if exist.