Harman Kardon AVR 132 (serv.man2) EMC - CB Certificate ▷ View online
- Page 23 of 32 -
www.nemko.com
Report No. 70635
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965:
No CRT in the equipment
N
Picture tube separately approved to 18.1 ...............
N
18.1
Picture tubes > 16 cm intrinsically protected
N
Non-intrinsically protected tubes > 16 cm used with
protective screen
protective screen
N
18.2
Intrinsically protected tubes: tests on 12 samples
N
18.2.1
Samples subject to ageing: 6
N
18.2.2
Samples subject to implosion test: 6
N
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N
18.3
Non-intrinsically protected tubes tested to 18.3
N
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg ................. :
Weight: 9,4 kg
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
No
N
19.1
Test on a plane, inclined at 10
o
to the horizontal
Tested on a plane inclined at
an angle of 10°
an angle of 10°
P
19.2
100 N force applied vertically downwards
100N force have no influence
on the stability
on the stability
P
19.3
Apparatus mass > 25 kg or height > 1 M or
supplied with cart or stand
supplied with cart or stand
< 25 kg, < 1M
N
19.4
Edges or corners not hazardous
There is no hazardous edges
or corners when the
apparatus is operating in
normal position
or corners when the
apparatus is operating in
normal position
P
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
maximum dimension > 450 mm, pass the test of
19.5.1
No glass surface
N
19.6
Wall or ceiling mountings adequate
Not intended for wall or ceiling
mounting
mounting
N
TRF No: IEC/EN 60065F
- Page 24 of 32 -
www.nemko.com
Report No. 70635
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
N
b) Exemption for small components as defined in
20.1
20.1
PCB is of flammability class
V-1 and exception is made for
small componets.
V-1 and exception is made for
small componets.
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components comply
with flammability requirements
in clause 14.
with flammability requirements
in clause 14.
P
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
No wires working at voltages
> 4kV or leaving an internal
fire enclosure
> 4kV or leaving an internal
fire enclosure
N
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
All PCB is of base material
with flammability category V-1
or better. See appended table
with flammability category V-1
or better. See appended table
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
No voltage exceeding 400V
(peak) a.c. or d.c.
(peak) a.c. or d.c.
N
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
No such components
N
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
No such components
N
20.2 Fire
enclosure
N
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No voltages exceeding 4kV,
no fire enclosure requirement
no fire enclosure requirement
N
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
No internal fire enclosure.
N
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
No internal fire enclosure.
N
TRF No: IEC/EN 60065F
- Page 25 of 32 -
www.nemko.com
Report No. 70635
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N
A.10.2.1
Enclosure provides protection against splashing water
N
A.10.2.2 Humidity
treatment carried out for 7 days
N
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
No connection to TNV circuits
N
Complies with IEC 62151 clause 2
N
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this standard
modified in accordance with annex B of this standard
N
Complies with IEC 62151 clause 6
N
Complies with IEC 62151 clause 7
N
Complies with IEC 62151 annex A, B and C
N
IEC 62151 clause 4.1.1:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries shall be
as follow:
In Finland,
"Laite on liitettävä suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries shall be
as follow:
In Finland,
"Laite on liitettävä suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Class II apparatus
N
TRF No: IEC/EN 60065F
- Page 26 of 32 -
www.nemko.com
Report No. 70635
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
In OFF/Stand-by position,
the power consumption is less
than 2,2W.
the power consumption is less
than 2,2W.
P
Position of the functional switch (W) ...................... :
—
Operating conditions
Standby mode:
Un (V)
In (A)
Pn (W)
Pout (W)
207 0,008 1,3 —
230 0,010 1,6 —
253 0,014 2,2 —
Measured at maximum non-clipped output:
Un (V)
In (A)
Pn (W)
Pout (W)
253
2,45
545
2 x 49,0 W
(F)
1 x 46,6 W
(C)
2 x 46,1 W
(S)
Measured at 1/8 of maximum non-clipped output:
Un (V)
In (A)
Pn (W)
Pout (W)
207 1,13
#) 1,05
189
#) 176
2 x 6,13 W
(F)
1 x 5,83 W
(C)
2 x 5,76 W
(S)
230 1,15
#) 1,09
212
#) 200
2 x 6,13 W
(F)
1 x 5,83 W
(C)
2 x 5,76 W
(S)
253 1,16
#) 1,12
237
#) 227
2 x 6,13 W
(F)
1 x 5,83 W
(C)
2 x 5,76 W
(S)
The input tests were conducted at 1 kHz sign wave input signal with 8 ohm loads connected conditions for
F, C and S channels, and than replaced the input signal to pink noise for heating and faukt condition tests.
F, C and S channels, and than replaced the input signal to pink noise for heating and faukt condition tests.
The values followed #) mark in table above are meaured “A” or “W” value, when replaced the input signal
from 1 kHz sign wave to pink noise.
from 1 kHz sign wave to pink noise.
Loudspeaker impedance (Ω) ....................
8 Ohm
P
Several loudspeaker systems
Right and Left for Front,
Only one for Center,
Right and Left for Surround
Only one for Center,
Right and Left for Surround
P
Marking of loudspeaker terminals
SPEAKERS ( 8Ω ):
FRONT, CENTER, SURROUND
P
TRF No: IEC/EN 60065F