Harman Kardon AVR 132 (serv.man2) EMC - CB Certificate ▷ View online
- Page 11 of 32 -
www.nemko.com
Report No. 70635
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
> 100 MΩ
P
10.2 Humidity
treatment 48 h or 120 h ........................... :
120 h (40°C). No impairment
P
10.3
Insulation resistance and dielectric strength
(see appended table)
P
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
No electric shock hazard under
fault conditions.
fault conditions.
P
11.2
Heating under fault condition
P
No hazard from softening solder
No solder soften.
P
11.2.1
Measurement of temperature rises
See appended table and
attachment, Table to
EN/IEC 60065 7
attachment, Table to
EN/IEC 60065 7
th
edition
P
11.2.2
Temperature rise of accessible parts
See appended table and
attachment, Table to
EN/IEC 60065 7
attachment, Table to
EN/IEC 60065 7
th
edition
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
See appended table and
attachment, Table to
EN/IEC 60065 7
attachment, Table to
EN/IEC 60065 7
th
edition
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
No area where temperature
exceeds 100K above limits
exceeds 100K above limits
N
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
No conductors are
interrupted/peeled/loosened
during fault conditions
interrupted/peeled/loosened
during fault conditions
N
Class I protective earthing maintained
Class II equipment
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
Temperature rises are within
the limits.
the limits.
P
11.2.5
Temperature rise of windings
See appended table and
attachment, Table to
EN/IEC 60065 7
attachment, Table to
EN/IEC 60065 7
th
edition
P
TRF No: IEC/EN 60065F
- Page 12 of 32 -
www.nemko.com
Report No. 70635
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
No excessive temperature
observed/measured on other
parts
observed/measured on other
parts
P
12 MECHANICAL
STRENGTH
12.1.1
Bump test where mass >7 kg
No damage in the sense of
this standard
this standard
P
12.1.2 Vibration
test
Assessed to be satisfactory
constructed.
constructed.
N
12.1.3
Impact hammer test
No damage in the sense of
this standard
this standard
P
Steel ball test
Complies
P
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
Not a portable apparatus.
N
12.1.5
Thermoplastic enclosures strain relief test
Tested, 70ºC, 7h
P
12.2
Fixing of knobs, push buttons, keys and levers
Normal use will not impair the
protection against electric
shock.
protection against electric
shock.
P
12.3
Remote controls with hazardous live parts
No remote controllers with
hazardous live parts.
hazardous live parts.
N
12.4
Drawers (pull test 50 N, 10 s)
No drawers
N
12.5
Antenna coaxial sockets providing isolation
No antenna socket which
insolate hazardous live parts from
accessible parts.
insolate hazardous live parts from
accessible parts.
N
12.6
Telescoping or rod antennas construction
No antenna
N
12.6.1
Telescoping or rod antennas securement
N
TRF No: IEC/EN 60065F
- Page 13 of 32 -
www.nemko.com
Report No. 70635
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition.
P
Creepage distances in accordance with 13.4
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition.
P
13.2
Determination of operating voltage
Conventional transformer
used.
Upper rated supply voltage
applied in determining the
operating voltage.
used.
Upper rated supply voltage
applied in determining the
operating voltage.
P
13.3 Clearances
2N for internal parts and 30N
for enclosures are considered
when determining clearances.
for enclosures are considered
when determining clearances.
P
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
No hazardous secondary
voltages
voltages
N
13.4 Creepage
distances
CTI > 100
See attachment, Table to
EN/IEC 60065 7
See attachment, Table to
EN/IEC 60065 7
th
edition
P
Creepage distances greater than table 11 minima
Not applicable
N
13.5 Printed
boards
N
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
No such PCB used
N
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
No type B coated PCB
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
Jointed insulation not applied
N
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
No enclosed, enveloped or
hermetically sealed parts
hermetically sealed parts
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
No parts filled with insulating
compound
compound
N
TRF No: IEC/EN 60065F
- Page 14 of 32 -
www.nemko.com
Report No. 70635
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14 COMPONENTS
14.1 Resistors
N
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
Not used
N
b) Resistors separately approved .......................... :
N
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes,
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. :
No Y capacitors
N
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. :
C904 is certified X capacitor
by IEC 60384-14, 2
by IEC 60384-14, 2
nd
edition
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
No such capacitors
N
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N
Shielded by a barrier to V-0 or metal ..................... :
N
14.3
Inductors and windings
See below.
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
Transformers evaluated
according to 14.3.3, 14.3.4
and 14.3.5
according to 14.3.3, 14.3.4
and 14.3.5
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
Adequate marking applied.
- Type no. and,
-.Manufacturer’s ID
- Type no. and,
-.Manufacturer’s ID
P
Transformers and inductors separately approved . :
No
N
14.3.2 General
Isolating transformer
P
14.3.3 Constructional
requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
TRF No: IEC/EN 60065F