- Page 15 of 32 - 
 
 
www.nemko.com
 
Report No.  70635 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Double or reinforced insulation  
between primary and secondary  
windings according to clause 8.8. 
 
Coil formers and partition walls > 0,4 mm 
The bobbin fulfils the 
requirement 
of reinforced insulation; bobbin 
thickness > 0,4 mm. 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II apparatus. No such 
transformer used. 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Double or reinforced insulation 
between hazardous live 
windings and accessible 
conductive parts. 
 
Coil formers and partition walls > 0,4 mm 
The bobbin fulfils the 
requirement 
of reinforced insulation; bobbin 
thickness > 0,4 mm. 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Windings of Class II 
construction used. 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 
14.4 
High voltage components 
No high voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 
 
Component meets category V-1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
14.5 Protective 
devices 
 
 
Protective devices used within their ratings 
Thermal link and fuse 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Certified protective devices 
applied. See appended table, 
list of critical components. 
TRF No:  IEC/EN 60065F 
 
 
- Page 16 of 32 - 
 
 
www.nemko.com
 
Report No.  70635 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14.5.1.1 
a) Thermal cut-outs separately approved 
None 
 
b) Thermal cut-outs tested as part of the 
submission 
 
14.5.1.2 
a) Thermal links separately approved 
The thermal links in main and  
sub transformer, separately  
approved, see appended table, 
list of critical components. 
 
b) Thermal links tested as part of the submission 
 
14.5.1.3 
Thermal devices re-settable by soldering 
No such thermal device 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
Fuses are certified according 
to IEC60127 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... :
Correct marking applied close 
to the fuse; 
F901: T4A L 250V 
14.5.2.3 
Not possible to connect fuses in parallel ............... :
No fuse holder so designed that 
fuse-links can be connected in 
parallel 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
No replacement of fuse  
possible by hand. 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
None 
 
PTC-S devices (15 W) category V-1 or better 
None 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
No such components 
14.6 Switches 
 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
Yes,  
Mains switch and relay provided. 
Certified acc. to IEC61058-1.  
- Mains switch, certified by VDE, 
- Mains relay, certified by 
SEMKO. 
 
See appended table, list of 
critical components. 
14.6.1 b) 
Tested in the apparatus: 
 
 
Switch controlling > 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 
 
Switch controlling > 0.2A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 
TRF No:  IEC/EN 60065F 
 
 
- Page 17 of 32 - 
 
 
www.nemko.com
 
Report No.  70635 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Switch controlling < 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
Separately approved switch 
and relay. 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
Separately approved switch 
and relay. 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
Separately approved switch 
and relay. 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1 
The apparatus is not provided 
the socket outlet, but 
measured 
the apparatus surge through, 
- Mains switch: 17 A peak 
- Mains relay: < 1 A peak  
 
The measured surge current 
value is less than rated surge 
current rating of the mains 
switch and relay. OK. 
 
Socket outlet current marking correct 
No mains socket outlet 
14.7 Safety 
interlocks 
No safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
 
14.8 
Voltage setting devices 
No voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
 
14.9 Motors 
No motors 
14.9.1 
Endurance test on motors 
 
 
Motor start test 
 
 
Dielectric strength test 
 
14.9.2 
Not adversely affected by oil or grease etc. 
 
14.9.3 
Protection against moving parts 
 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 
and B.10 of IEC 60950, Annex B 
 
TRF No:  IEC/EN 60065F 
 
 
- Page 18 of 32 - 
 
 
www.nemko.com
 
Report No.  70635 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14.10 Batteries 
No batteries 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 
14.10.3 
Recharging currents and times within 
manufacturers limits 
 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
 
14.10.4 
Battery mould stress relief 
 
14.10.5 
Battery drop test 
 
14.11 Optocouplers 
No optocouplers 
 
Optocouplers comply with Cl. 8 
 
 
Internal and external dimensions to 13.1. or 
alternatively 13.6 (jointed insulation) 
 
14.12 
Surge suppression varistors 
No surge suppression varistors 
 
Comply with IEC 61051-2 
 
 
Not connected between mains and accessible 
parts except for earthed parts of permanently 
connected apparatus 
 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 
TRF No:  IEC/EN 60065F 