Sony GV-D1000 Service Manual ▷ View online
2-1
SECTION 2
DISASSEMBLY
GV-D1000/D1000E
COVER
COVER
The following flow chart shows the disassembly procedure.
GV
-D1000/D1000E
2-1. LCD cabinet assembly
2-3. LCD window cabinet assembly
(LCD901, ND901, SP901, SP902)
(LCD901, ND901, SP901, SP902)
2-4. Bottom cabinet assembly, FP-571 flexible board
(V/L rechargeable battery)
(V/L rechargeable battery)
2-7. FP-575 flexible board (LANC),
PR-41 board, IO-69 board
PR-41 board, IO-69 board
2-2. PD-130 board, LS-56 board
2-13. FP-602 flexible board (DV IN/OUT),
LCD block assembly
LCD block assembly
PD-130 board service position
2-8. MS-95 board
2-5. VC-275 board
2-9. Mechanism deck
2-11. EX-39 board
2-10. EJ-35 board
2-6. Battery terminal board
2-12. MS connector, FK-81 board
2-14. Hinge unit , FP-569 flexible board
[SERVICE POSITION TO CHECK THE VTR SECTION (Mainly for voltage measurement and check)]
(VC-275, MS-95, IO-69, PR-41 boards, Mechanism deck)
(VC-275, MS-95, IO-69, PR-41 boards, Mechanism deck)
[CONNECTION OF EQUIPMENT]
Adjustment remote
commander (RM-95)
commander (RM-95)
AC IN
AC power
adaptor
adaptor
2-2
GV-D1000/D1000E
NOTE:
Follow the disassembly procedure in the numerical order given.
2-1. LCD CABINET ASSEMBLY
2
Two screws (M2
×
4),
lock ace, p2
3
Two screws (M2
×
3),
lock ace, p2
1
Two screws (M2
×
4),
lock ace, p2
5
Two
claws
4
Two
claws
6
Remove the LCD cabinet assembly
in the direction of the arrow.
AC POWER
ADAPTOR
ADAPTOR
AC IN
PD-130
Board
PD-130 board
Touching here is safe when the machine
is normal. However touching here can be
dangerous if defective parts exist.
is normal. However touching here can be
dangerous if defective parts exist.
Caution :
High voltage
High voltage
CN5502
LS-56 board
CN001 (2P)
CN001 (2P)
CN5607
Adjustment remote
commander (RM-95)
commander (RM-95)
Multi-CPC jig
(J-6082-311-A)
(J-6082-311-A)
[PD-130 BOARD SERVICE POSITION]
1
9
10
2
When the hinge unit is closed to be laid down,
remove CN001 (2P) on the LS-56 board.
If not, the main power cannot be turned on.
remove CN001 (2P) on the LS-56 board.
If not, the main power cannot be turned on.
LANC
jack
jack
2-3
GV-D1000/D1000E
2-2. PD-130 BOARD, LS-56 BOARD
PD-130
Board
0
Remove the PD-130 board
in the direction of the arrow.
9
Three screws (M2
×
3),
lock ace, p2
2
Two tapping screws
(B2
×
6)
qa
Screw (M2
×
3),
lock ace, p2
1
Harness (PL-53) (2P)
6
SP901 (2P)
7
ND901 (10P)
qd
LS bracket
8
LCD901 (24P)
5
SP902 (2P)
4
Harness (EP-51) (2P)
qs
Screw (M2
×
3),
lock ace, p2
qf
LS-56 board
3
FP-569 flexible
board (26, 32P)
2-4
GV-D1000/D1000E
2-3. LCD WINDOW CABINET ASSEMBLY (LCD901, ND901, SP901, SP902)
1
Two tapping screws
(B2
×
6)
2
Two tapping screws
(B2
×
6)
3
Screw (M2
×
3),
lock ace, p2
5
PD frame
6
LCD901
4
LCD ground plate
8
Two claws
7
Two claws
9
ND901
1
Tapping screw
(B2
×
6)
5
Tapping screw
(B2
×
6)
3
SP ground plate
4
SP902
6
SP ground plate
7
SP901
8
LCD window cabinet
assembly
REMOVING THE LCD WINDOW
CABINET ASSEMBLY (SP901, 902)
CABINET ASSEMBLY (SP901, 902)
2
Remove the SP ground plate
in the direction of the arrow.
Dowel
Claw
Click on the first or last page to see other GV-D1000 service manuals if exist.