– 33 –
KV-XA21M30/XA21M63
RM-952
KV-XA21N90
RM-915
• The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
• These adjustments should be performed with rated power
supply voltage unless otherwise noted.
Controls and switches should be set as follows unless otherwise noted:
PICTURE control ...........................................................  normal
BRIGHTNESS control ...................................................  normal
Perform the adjustments in the following order :
1. Beam Landing
2. Convergence
3. Focus
4. White Balance
Note :  Test Equipment Required.
1. Pattern Generator
2. Degausser
3. Oscilloscope
SECTION 3
SET-UP ADJUSTMENTS
................................................................................................................................................................................................................................
normal
Preparation :
• In order to reduce the influence of geomagnetism on the set's
picture tube, face it east or west.
• Switch on the set's power and degauss with the degausser.
3-1. BEAM LANDING
1. Input a white signal with the pattern generator.
Contrast
Brightness
2. Set the pattern generator raster signal to a green raster.
3. Move the deflection yoke to the rear and adjust with the
purity control so that the green is at the center and the blue
and the red take up equally sized areas on each side.
(See Figures 3-1 through 3-4.)
4. Move the deflection yoke forward and adjust so that the
entire screen is green. (See Figure 3-1.)
5. Switch the raster signal to blue, then to red and verify the
condition.
6. When the position of the deflection yoke has been decided,
fasten the deflection yoke with the screws and DY spacers.
7. If the beam does not land correctly in all the corners, use a
magnet to adjust it.
(See Figure 3-4.)
}
Fig. 3-1
Fig. 3-4
Fig. 3-3
Fig. 3-2
Purity control
Red
Blue
Green
Purity control
corrects this area.
Disk magnets or rotatable
disk magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
a
b
b
c
c
d
d
a
– 34 –
KV-XA21M30/XA21M63
RM-952
KV-XA21N90
RM-915
3-2. CONVERGENCE ADJUSMENT
Preparation :
• Before starting this adjustment, adjust the focus, horizontal size
and vertical size.
• Receive dot/hatch signal.
• Pic mode: Personal (Pic 90%, Brightness 50%, Col 50 %,
Hue 50%, Shp 50%).
(1)
Horizontal and Vertical Static Convergence
1. (Moving horizontally), adjust the H.STAT control so that the
red, green and blue dots are on top of each other at the center of
the screen.
2. (Moving vertically), adjust the V.STAT magnet so that the red,
green and blue dots are on top of each other at the center of the
screen.
3. If the H.STAT variable resistor cannot bring the red, green and
blue dots together at the center of the screen, adjust the
horizontal convergence with the H.STAT variable resistor and
the V.STAT magnet in the manner given below.
(In this case, the H.STAT variable resistor and the V.STAT
magnet influence each other, so be sure to perform adjustments
while tracking.)
1
V. STAT
2
H. STAT VR
3
Center dot
R    G    B
R
G
B
H. STAT VR
V. STAT
Magnet
RV702
H. STAT
C1 Board
BMC (Hexapole)
V.STAT
DY pocket
Purity
V.STAT
BMC
Purity
R
R
R
R
G
G
G
G
B
B
B
B
a
a
a
b
b
b
b
R
R
G
G
B
B
a
a
b
b
b
– 35 –
KV-XA21M30/XA21M63
RM-952
KV-XA21N90
RM-915
(3) Screen-corner Convergence
YCH
Rotate
YCH
VOL on DY
TLV
Insert
TLH
Correction Plate to DY Pocket (Left or
Right)
ON DY:
b
a
c
d
a-d : screen-corner
        misconvergence
YCH
TLV
(2) Dynamic Convergence Adjustment
Preparation:
• Before starting this adjustment, adjust the horizontal static
convergence and the vertical static convergence
4
BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned, then
use the BMC magnet to adjust in the manner described below.
R G
B
R
G
B
R
G B
R
B
R
G
G
G
B
R
B
R B
TLV
YCH
B
R
– 36 –
KV-XA21M30/XA21M63
RM-952
KV-XA21N90
RM-915
2. WHITE BALANCE ADJUSTMENT
1) Set to Service Mode (Refer Section 5-1: ADJUSTMENTS
WITH COMMANDER).
2) Input white raster signal.
3) Set the PICTURE to minimum.
4) Select GCT (WHB 4) and BCT (WHB 5) with [1] and [4], and
adjust the level with [3]  and [6] for the best white balance.
5) Set the PICTURE to maximum.
6) Select GDR (WHB 1) and BDR (WHB 2) with [1] and [4],
and adjust the level with [3] and [6] for the best white
balance.
7) Write into the memory by pressing [MUTING] then [0].
3. SUB BRIGHT ADJUSTMENT
1) Set to service mode.
2) Input a staircase signal of black to white from the pattern
generator.
3) BRIGHTNESS .... 50%.
PICTURE ............ MINIMUM
4) Select SBR (WHB7) with [1] and [4], and adjust SBR
(WHB7) level with [3] and [6] so that the second stripe from
the right is dimly lit.
3-4. G2 (SCREEN) AND WHITE BALANCE
ADJUSTMENTS
1. G2 (SCREEN) ADJUSTMENT
1) Set the PICTURE to normal.
2) Put to VIDEO input mode without signals.
3) Connect R, G and B of the C1 board cathode to the
oscilloscope.
4) Adjust BRIGHTNESS to obtain the cathode voltage to the
value below.
5) Adjust G2 (screen) on the FBT until picture shows the point
before cut off.
White
second from the right
Black
0 V
Cathode setting voltage:
175 V 
± 2 (VDC)
Fix a Permalloy assy corresponding to the misconverged
areas.
3-3. FOCUS ADJUSTMENT
FOCUS adjustment should be completed before W/B adjustment.
1.
Receive digital monoscope pattern.
2.
Set "Picture Mode" to "DYNAMIC".
3. Adjust focus VR so that the center of screen becomes just
focus.
4. Change the receiving signal to white pattern and blue back.
5. Confirm magenta ring is not noticeable. Incase magenta is very
obvious, adjust focus VR to take balance of magenta ring and
focus.
a
b
c
d
Permalloy assembly
FLYBACK TRANSFORMER  (T503)
Screen
Focus
Page of 83
Display

Click on the first or last page to see other KV-XA21M30 service manuals if exist.