– 4 –
KV-SK29M80/H
RM-GA002
[+B overcurrent $OCP%]
Occurs when an overcurrent on the +B(135V) line is detected by pin 32 of IC001 (A board).
If the voltage of pin 32 of IC001 (A board) is more than 4V, the unit will automatically go to
standby.
[V-PROTECT]
Occurs when an absence of the vertical deflection pulse is detected by pin 13 of IC001
(A board).
[IK $AKB%]
If the RGB levels* do not balance within 15 sec after the power is turned on, this error will be
detected by IC001 (A board). TV will stay on, but there will be 5 times LED blinking.
Occurs when IC001 internal HV protect detects an abnormal H-Pulse (frequency) due to
improper power supply to IC001. TV cuts off high voltage power of anode CRT. No picture will be
detected. eg: IC602, IC604 go faulty.
* (Refers to the RGB levels of the AKB detection Ref pulse that detects IK.)
A BOARD
IC001
Y/CHROMA JUNGLE
A BOARD
IC804
V.OUT
A BOARD
IC001
SYSTEM
A BOARD
IC003
MEMORY
FROM
CV BOARD
IC751 PIN 5
IK
EHTO
RED LED
DISPLAY
SDA1
V.GUARD
SDA
5
F.B-PLS
3
13
84
32
122
A BOARD
FROM
Q816
COLLECTOR
99
POWER SUPPLY NG (+5V)
for VIDEO PROCESSOR
4. SELF DIAGNOSTIC SCREEN DISPLAY
5. HANDLING SELF DIAGNOSTIC SCREEN DISPLAY
6. SELF-DIAGNOSTIC CIRCUIT
2 : 
000
3 :
N/A
4 :
000
5 :
001
8 :
002
101 :
N/A
"0" means no fault has been detected.
"1" means a fault has been detected.
"2" means two faults has been detected.
"N/A" means not available for this models.
SELF DIAGNOSTIC
5
8
No.
Description
Method
1.
Display self diagnostic screen
[Display] t [Channel    ] t [Volume    ] t [Power / TV]
Note: The above must be performed while TV is on standby mode.
2.
Stop standby flash
i) Turn off power switch on main.
ii) Unplug power cord from the outlet.
3.
Clear fault result
In self diagnostic screen, press 
[Channel    ] t 
-
Note: Diagnostic results display on screen is not automatically cleared. Therefore,
clear result after completion of repair.
4.
Quit self diagnostic screen
Turn off power switch of remote commander or main unit.
– 5 –
KV-SK29M80/H
RM-GA002
SECTION 1
DISASSEMBLY
1-2.
SPEAKER REMOVAL
1-3.
CHASSIS ASSY REMOVAL
1-4.
SERVICE POSITION
1-5.
A BOARD AND H2 BOARDS REMOVAL
1-1.
REAR COVER REMOVAL
1
  Eleven 
      screws
      (+BVTP 
      4 
× 16)   
2
 Rear cover
1 Two screws
       Tapping screw 
       (+PWH 4x16)
2 H2 Board
1 Two Hooks
3 A Board
– 6 –
KV-SK29M80/H
RM-GA002
1-6.
PICTURE TUBE  REMOVAL
Note:
Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom
right and left.
1) Remove the rear cover.
2) Unplug all interconnecting leads from the Deflection yoke, Neck assy, Degaussing Coil and CRT grounding strap.
Remove Chassis Assy.
3) Place the TV set with the CRT face down on a cushion jig.
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or
carbon paint on the CRT.
REMOVING PROCEDURES
Turn up one side of the rubber cap in the direction
indicated by the arrow a.
Using a thumb pull up the rubber cap firmly in the direction
indicated by the arrow b.
When one side of the rubber cap is separated from the
anode button,  the anode-cap can be removed by turning
up the rubber cap and pulling it up in the direction of the
arrow 
c.
HOW TO HANDLE AN ANODE-CAP
Do not damage the surface of anode-caps with sharp
shaped objects.
Do not press the rubber too hard so as not to damage
the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built
into the rubber.
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the
rubber.
a
a
b
b
c
 Anode Button
4
 Anode Cap Removal
6
 Degaussing Coil
0
 Loosen the Neck Assembly 
 
fixing screw and remove
 
Neck Assy & VM board
qa
 Loosen the Deflection Yoke
 
fixing screw and remove
9
 CV Board Removal
7
 Spring Tension(2) 
 
Removal
qs
 Screw, Tapping 7+
 
Crown Washer
qd
 Supports, CRT(2) Removal
5
 Band, DGC Removal
8
 Earth Coating Assy
– 7 –
KV-SK29M80/H
RM-GA002
SECTION 2
WIRE DRESSING
2-1.  Lead Assy, Jumper wire dressing at A board
2-3.  Wire Dressing at A and H2 board
2-2.  Dressing of Conn Assy, 4P VH
 
 
 
 
 
W082
P/N 1-910-026-28
CN905
Dress Lead Assy, Jumper
far away from C514 and T501
i) Insert and dress Conn Assy, 4P into hook.
W010
T501
C514
W084
W065
Conn Assy,
5P YUV
W077
Dress both Lead Assy,
Jumpers along edge of shield case
Dress Conn Assy, 4P VH into hook as shown.
W016
Keep Lead Assy,
Jumpers away from R121
Dress both Lead
Assy, Jumpers
around CN905,
C903 and
below Conn
Assy, 5P YUV
Insert Connector Assy,
4P VH into holder
CN6101
CN4102
CN4113
Conn Assy, 7P
Insert Conn
Assy, 4P into
hook
CN4110
1
ii) Insert Conn Assy, 5P into CN4105.
Make sure AC Power Cord is behind Lead Assy, Speaker at CN4106.
Conn Assy, 4P
CN3102
CN2105
AC Power
Cord is
behind Lead
Assy Speaker
CN4106
Conn Assy, 5P
CN4105
Lead Assy, Speaker
C903
2
TVSR Requirement :
Connector assy must be kept away from primary area (10mm minimum)
P/N 1-923-512-11
CAUTION:
1.  Do not overpull the wire during dressing
     _> avoid disconnection of wires.
2.  Make sure wires are kept away from
     sharp edges, heatsinks & other
     hight-temperature parts.
Legend:
Hook
Page of 88