DOWNLOAD Sony KV-SK29M80 Service Manual ↓ Size: 6.64 MB | Pages: 88 in PDF or view online for FREE

Model
KV-SK29M80
Pages
88
Size
6.64 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kv-sk29m80.pdf
Date

Sony KV-SK29M80 Service Manual ▷ View online

– 12 –
KV-SK29M80/H
RM-GA002
2-15.  Dress Lead Assy, Speaker to Rotation Coil using purse lock Ø 9
2-16.  Dressing of PF board conn assy 
 
(for models with PF board only)
2-17.  Cap Assy, High Voltage installation
  
 
DY
 
 
D604
A007
90
°
Rotation 
>5m
Keep distance
of 1mm/kV
Keep distance of
0.5mm/kV
Earth Assy,
Coating wire
Earth Assy, Coating
wire is above
Lead Assy, Speaker
Figure (a)
Dress Lead Assy, Speaker
to center position of Rotation 
Coil using purse lock Ø 9
Rotation coil
Lead
Assy, Speaker
Lead Assy, Speaker goes
behind DGC
Pull wire to
the right
Figure(b)
Rotation Coil
Lead Assy, Speaker
(RED+BLK)
Purse 
lock Ø 9
PP tape of DGC
Figure(c)
DGC Connector
Pull wire to left
Dress DGC conn wire
behind PP tape and DGC 
before inserting to plug
Dress Lead Assy,
Speaker directly on to
DGC using purse lock Ø 11
Lead Assy,
Speaker goes
behind
Rotation Coil
Lead Assy, Speaker
Attach purse lock Ø 9 here
Connector Assy, 
3P VH
DGC Connector is below Conn
Assy, 3P VH
to keep Conn Assy, 3P VH away
from Heat Sink A007 and D604
CN605
DGC Band
Dress Lead Assy, Speaker to center position of Rotation coil Make sure Earth assy,
Coating wire is above Lead Assy, Speaker This is to keep Lead Assy, Speaker away from Deflection Yoke.
Keep wires away from
heatsinks A007, D604 and
conductive parts
TVSR Requirement:
1. Keep HV cable away from conductive parts (distance of
1mm/kV).
2. Keep spacing between edge of anode cap & conductive parts
(distance of 0.5mm/kV).
3. Keep spacing between edge of anode cap & non-conductive
parts (distance of at least 5mm or more).
DG
HV 
– 13 –
KV-SK29M80/H
RM-GA002
2-18.  HV cap assy wire dressing
2-19.  AC Power Cord Wire Dressing
ii)
DGC
90°
630 ± 5mm 
 
 
 
i) Dress Cap Assy, High Voltage with Holder, HV cable combi as shown.
Caution: 1) Make sure the specified position is being followed.
 
2) Position the Cap Assy, High Voltage in the inner ring of the
 
  Holder, HV cable combi (see diagram).
Install AC cord holder to AC power cord at specified position as shown.
HV cap
CRT's carbon
area
Dress Holder, HV Cable Combi
to Cap Assy, High Voltage
TVSR requirement:
1. Spacing between HV cable and other conductive part’s
  surface is 1mm/kV or more.
2. Spacing between HV cable's and enclosure with ventilation or
  the edge where terminal bracker and rear cover meet:10mm or more.
Caution:
-  Please ensure that the portion of HV cable above the holder, HV 
  cable combi is kept away from CRT'S carbon area
-  Also, portion of HV cable below the holder, HV cable combi needs
  to be kept away from conductive parts (DGC, rotation coil, CRT'S
  carbon area, speaker wire etc)
-  Ensure for ming of HV cable is ok and no unnatlural curve occurs.
CRT's carbon
area
Min. distance = 1mm/kV
Min. distance = 1mm/kV
Holder, HV cable combi
230 ± 5 mm
DGC
Inner Ring
Make sure AC cord is
straight between boss and holder
Attach AC cord onto
holder and insert to bottom cover
Attach Purse Lock (S)
Ø 8 in to rear cover
Dress behind boss
Hook AC cord into
CRT support's hook
– 14 –
KV-SK29M80/H
RM-GA002
The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
The controls and switch should be set as follows unless
otherwise noted:
Picture Control....................................."NORMAL"
Brightness Control..............................."NORMAL"
Perform the adjustments in order as follows :
1. Beam Landing
2. Convergence
3. Focus
4. G2(SCREEN)
5. White Balance
Note : Test Equipment Required.
1. Pattern Generator
5. Oscilloscope
2. Degausser
6. Landing Checker
3. DC Power Supply
7. XCV Adjuster
4. Digital Multimeter
SECTION 3
SET-UP ADJUSTMENTS
Preparation :
• Feed in the white pattern signal.
• Before starting, degauss the entire screen with the
degausser.
• In order to reduce the geomagnetism on the set's picture
tube, face it east or west.
3-1. BEAM LANDING ADJUSTMENT
1. Input a raster signal with the pattern generator.
2. Loose the deflection yoke(DY) mounting screw, and set
the purity control to the center as shown below:-
3. Position VM coil as shown below:-
4. Set the raster signal of the pattern generator to green.
5. Move the DY backward and adjust the purity control so
that green is in the center and blue and red are at the
sides evenly.
Red
Blue
Green
a
b
b
c
c
d
d
a
Purity control
corrects this area.
Disc magnets or rotatable
disc magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
Purity control
VM coil
G2
G1
G3
Align the edge of
the VM coil with
the edge of the G3 grid.
G4
......................................................................................................................................................................................................................
6. Then move the DY forward and adjust so that the entire
screen becomes green.
7. Now switch over raster signal to red then blue and
confirm the condition.
8. When the position of the DY is determined, tighten it with
the DY mounting screw.
9. If the beam does not land correctly in all the corners of
the screen, use magnet disc to correct it.
– 15 –
KV-SK29M80/H
RM-GA002
Moved RV750 (H.STAT)
R
R
G
G
B
B
A
A
B
B
B
B
R
G
G
R
B
3-2. CONVERGENCE ADJUSTMENT
Preparation:
• Before starting, perform FOCUS adjustment.
• Picture Mode "CUSTOM"
• Receive dot/cross hatch pattern.
1. (Moving vertically), adjust the 4 pole magnet to
converge red, green and blue dots in the center of
the screen.
2. Tilt the 4 pole magnet and adjust static convergence
to open or close the 4 pole magnet.
3. When the 4 pole magnet is moved in the direction of
arrow A and B, the red, green and blue dots moves
as shown below:-
a) Vertical Static Convergence
b) Horizontal Static Convergence
If the blue dots does not converge with the red and
green dots, use the 6 pole magnet to adjust in
the manner described below:-
c) Y Separation axis correction magnet adjustment.
1. Receive cross hatch signal.
2. Set Picture to "MINIMUM", Brightness to "STANDARD".
3. Adjust the Y separation axis correction magnet on
the Neck Assembly so that the horizontal lines at
the top and bottom of the screen are straight.
Red
Blue
Red
Blue
6 Pole Magnet
4 pole Magnet
DY pocket
Purity
6 Pole
Magnet
4 Pole
Magnet
R G
B
R
G
B
R
G B
R
B
R
G
G
G
B
R
B
4 pole magnet
RV750
H. STAT
RV1800
G2 (SCREEN) 
Center dot
R     G     B
G
R
B