— 21 —
KV-32HS500/32HV600/34DRC500/34XBR800/36HS500/
36XBR800/38DRC500/40XBR800/42DRC800 
2-9.3. VERTICAL COMPRESSED MODE 
CHECK AND CONFIRMATION 
(FOR 4X3 CRT ONLY)
1.  Input a monoscope and crosshatch signal.
2.  Check vertical compressed mode.
3.  Adjust VPIN if needed.
2-9.4. TWIN MODE/FAVORITE/
INDEX/NORMAL MODE GEOMETRY 
CONFIRMATION
TWIN mode and FAVORITE mode use the FULL mode adjustment data. 
The key point for TWIN mode adjustment is the blue border appearance. 
The left border on the left picture should not be visible when the left 
picture is selected. Similarly, the right border on the right picture should 
not be visible when the right picture is selected. Balance the HPOS or 
HSIZ data for FULL and TWIN mode.
For INDEX mode, however, (XBR sets only), no clipping of the picture 
edge should be visible for the small sampled pictures on the right side. 
Adjust HSIZ/HPOS to balance FULL and INDEX mode for this. Avoid 
displaying the edge of the raster in FULL or FAVORITE mode.
— 22 —
KV-32HS500/32HV600/34DRC500/34XBR800/36HS500/
36XBR800/38DRC500/40XBR800/42DRC800 
SECTION 3: SAFETY RELATED ADJUSTMENTS
3-1. PREPARATION BEFORE 
CONFIRMATION
Standard ............................................................................. 135.3 ± 1 VAC
Check Condition:
 
AC input voltage: 120 (± 2) VAC 
Note
If using a stabilized power supply, make sure that the distortion 
  
factor is 3% or less. 
Setting Mode:........................................................................... Full mode
Signal Input:...........................................................Cross-hatch of NTSC
Initial Setting:...................................................Standard Reset condition
Confi rm Point:.......................... Across CN5509 PIN 9 for B+ of D Board
3-1.1 HOLD-DOWN 
OPERATION 
CONFIRMATION
1.  Using an external DC power supply, apply 5.3 ± 0.5 Vdc between 
Pin 2 of CN507 (jig connector) and ground (Pin 8); confi rm set goes to 
hold-down (main power relay click).
2.  Remove the external DC power supply.
3-2.  B+ MAX CONFIRMATION
Standard ............................................................................. 135.3 ± 1 VAC
Check Condition:
 
AC input voltage: 120 (± 2) VAC 
Note
If using a stabilized power supply, make sure that the distortion 
  
factor is 3% or less. 
Setting Mode:........................................................................... Full mode
Signal Input:...........................................................Cross-hatch of NTSC
Initial Setting:...................................................Standard Reset condition
Confi rm Point:.......................... Across CN5509 PIN 9 for B+ of D Board
— 23 —
KV-32HS500/32HV600/34DRC500/34XBR800/36HS500/
36XBR800/38DRC500/40XBR800/42DRC800 
3-3.  HV SERVICE FLOWCHART
— 24 —
KV-32HS500/32HV600/34DRC500/34XBR800/36HS500/
36XBR800/38DRC500/40XBR800/42DRC800 
4-1.  SETTING SERVICE ADJUSTMENT MODE
1.  Standby mode (Power off).
2.  Press the following buttons on the remote commander within a 
second of each other: 
 
DISPLAY  
 Channel  5  
 Sound Volume  +  
 Power
4-1.1.  SERVICE ADJUSTMENT MODE IN
 
     
Disp.
(Item)
Item
data
0
VP
HSIZ
7
TV
Item
order
SERVICE
Mode
3.  The CRT displays the item being adjusted.
4.  Press   1  or  2  on the Remote Commander to select the item.
5.  Press  3  or   6  on the Remote Commander to change the data.
6.  Press MUTING then ENTER to write into memory.
4-1.2. SERVICE ADJUSTMENT MODE 
MEMORY
Disp.
(Item)
Item
data
SERVICE
0
VP
HSIZ
7
TV
Item
order
ENTER
MUTING
Red
Green
7.  Press  then  on the Remote Commander to initialize.
Disp.
(Item)
Item
data
WRITE
0
VP
HSIZ
7
TV
Item
order
8.   DO NOT turn off set until SERVICE appears.
4-1.3.  READING THE MEMORY
1.  Enter into Service Mode.
2.  Press  0  on the Remote Commander.
3.  Press  ENTER  to read memory.
4-1.4.  ADJUSTING THE PICTURE
1.  Enter into Service Mode
2.  Press  2  or  5  on the remote to select the device item.
3.  Press  1  or  4  on the remote to select an item.
4.  Press  3  or  6  on the remote to change the data.
5.  Press  MUTING  then  ENTER  to write into memory.
4-1.5.  RESETTING THE DATA
 
Note:  Be careful when using the remote!  It will clear and re-initialize 
  
ALL NVM data including defl ection adjustment data if not reset 
  
properly as follows:
4-1.6.  RESETTING THE MID NVM DATA
1.  Enter into Service Mode.
2.  Press  7 , then  JUMP , and then press  ENTER  on the remote.
4-1.7.  RESETTING THE SYSTEM NVM DATA
1.  Enter into Service Mode.
2.  Press  7 , then  9 , and then press  ENTER  on the remote.
4-1.8. COPY FUNCTION
How to use copy function for DA4 Chassis:
•  After writing your adjusted data into NVM  MUTING  
then  ENTER  , copy can be made by changing copy data from  0  to 
1  then  MUTING ,  ENTER  again.
WARNING:   DO NOT copy data before writing your corrected data in 
NVM. If data is copied before writing corrected data, old 
data will be copied.
•  CPY1: DF/DQP DATA 
(CXA2170D-4 Item 6)
•  CPY2: CONVERGENCE DATA  (D-CONV Item 13)
SECTION 4:  CIRCUIT ADJUSTMENTS
ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER
Use the Remote Commander (RM-Y170, RM-Y171) to perform the circuit adjustments in this section.
Test Equipment Required:   1. Pattern generator   2. Frequency counter   3. Digital multimeter  4.  Audio oscillator