— 21 —
KV-29FV15A/34FV15A/38FX250A
SECTION 2
DISASSEMBLY
2-1.  REAR COVER REMOVAL
2-2.  CHASSIS ASSEMBLY REMOVAL
Twelve Screws
(BVTP 4x16)
Two Screws
(BVTP 3x12)
(KV-29FV15A)
(KV-34FV15A/38FX250A)
1
1
1
1
  
  
Eleven Screws
      (BVTP 4x16)
3
3
3
3
3
One Screw
(BVTP 4x20)
Four Screws
   (BVTP 3x12)
AK Board
HA Board
GA Board
A Board
Chassis Assembly
UY Board
HB Board
Claw
T  Board
(KV-38FX250A Only)
HZ Board
— 22 —
KV-29FV15A/34FV15A/38FX250A
2-4.  MULTI-BUTTON SWITCH REMOVAL
2-3.  SERVICE POSITION
Top Multi-Button Switch
Two Screws
(+BVTP 4x16)
Bottom Multi-Button Switch
A Board
GA Board
AK Board
— 23 —
KV-29FV15A/34FV15A/38FX250A
2-5.  PICTURE TUBE REMOVAL
Coated earth ground strap
 Do not use sharp objects which may cause damage to the sur-
face of the anode-cap.
 Do not squeeze the rubber covering too hard to avoid damaging
the anode-cap. A material fitting called a shatter-hook terminal is
built into the rubber.
 Do not force turn the foot of the rubber cover. This may cause the
shatter-hook terminal to protrude and damage the rubber.
HOW TO HANDLE AN ANODE-CAP
 Turn up one side of the rubber cap in
the direction indicated by arrow 
.
 When one side of the rubber cap sepa-
rates from the anode button, the anode-
cap can be removed by turning the rub-
ber cap and pulling it in the direction of
arrow 
.
 Use your thumb to pull the rubber cap
firmly in the direction indicated by
arrow 
.
WARNING: High voltage remains in the CRT even after the power is disconnected. To avoid electrical shock, discharge CRT before
attempting to remove the anode-cap. Short between anode and coated earth ground strap of CRT.
NOTE:
After removing the anode, short circuit the anode of the picture tube and the anode cap to either the metal chassis, CRT
shield, or carbon painted on the CRT.
REMOVAL PROCEDURES
WARNING:
BEFORE REMOVING
ANODE-CAP:
High voltage remains in the CRT even after
the power is disconnected. To avoid electrical
shock, discharge CRT before attempting to
remove the anode-cap. Short between anode
and coated earth ground strap of CRT.
ANODE-CAP REMOVAL
Four screws
(Tapping screw 7)
 
Chassis
 GA board
A board
 AK board
 Anode-cap
Cushion
 
Deflection yoke
Neck assy
UY board
 Picture tube
 C board
— 24 —
KV-29FV15A/34FV15A/38FX250A
SECTION 3
SET-UP ADJUSTMENTS
3-1.  BEAM LANDING
Preparation:
1.
Input white pattern from pattern generator.
2.
Loosen the deflection yoke mounting screw, and set
       the purity control to the center as shown below:
3.
Input green pattern from pattern generator.
4.
Move the deflection yoke backward, and adjust with
the purity control so that green is in the center and
red and blue are even on both sides.
B
R
G
 Perform the adjustments in order as follows:
1. Beam Landing
2. Convergence
3. Focus
4. Screen (G2)/White Balance
  Note:  Test Equipment Required:
1. Color Bar Pattern Generator
2. Degausser
3. DC Power Supply
4. Digital Multimeter
5. Oscilloscope
6. CRT Analyzer
Input a white pattern signal.
Face the picture tube in an East or West direction to reduce the influence of geomagnetism.
NOTE: Do not use the hand degausser because it magnetizes the CRT .
5.
Move the deflection yoke forward, and adjust so that
the entire screen becomes green.
6.
Switch over the raster signal to red and blue and
confirm the condition.
7.
When the position of the deflection yoke is determined,
tighten it with the deflection yoke mounting screw.
8.
When landing at the corner is not right, adjust by using  the
disk magnets.
a
b
c
d
d
a
c
Purity control
corrects this area.
Disk magnets or
rotatable disk
magnets correct
these areas(a-d).
Deflection yoke positioning
corrects these areas.
b
   The following adjustments should be made when a
   complete realignment is required or a new picture
   tube is installed.
   These adjustments should be performed with rated
   power supply voltage unless otherwise noted.
   The controls and switch should be set as follows
   unless otherwise noted:
PICTURE control ................. normal
BRIGHTNESS control ......... normal