The following adjustments should be made when a complete realignment 
is required or a new picture tube is installed. 
These adjustments should be performed with rated power supply voltage 
unless otherwise noted.
Set the controls as follows unless otherwise noted:
Picture control 
NORMAL
Brightness control  NORMAL
SECTION 2:  SET-UP ADJUSTMENTS
Perform the adjustments in order as follows:
 1. 
Beam 
Landing
 2. 
Convergence
 3. 
Focus
 4. 
Screen 
(G2)
 5. 
White 
Balance
Note Test Equipment Required:
 
1. 
Color Bar Pattern Generator
 2. 
Degausser
 
3. 
DC Power Supply
 4. 
Digital 
Multimeter
2-1. BEAM LANDING
Before beginning adjustment procedure:
1.  Feed in the white pattern signal.
2.  In order to reduce the geomagnetism on the set’s picture tube, face 
it east or west.
Adjustment Procedure
1.  Input a raster signal with the pattern generator.
2.  Loosen the defl ection yoke (DY) mounting screw, and set the purity 
control to the center as shown below:
Purity control
3.  Position the VM coil as shown below:
VM coil
G2
G1
G3
Align the edge of
the VM coil with
the edge of the G3 grid.
G4
4.  Set the raster signal of the pattern generator to green.
5.  Move the defl ection yoke backward, and adjust with the purity 
control so that green is in the center and red and blue are even on 
both sides. 
Red
Blue
Green
6.  Move the defl ection yoke forward, and adjust so that the entire 
screen becomes green. 
7.  Switch over the raster signal to red, then blue and confi rm the 
condition.
8.  When the position of the defl ection yoke is determined, tighten it 
with the defl ection yoke mounting screw.
9.  If landing at the corner is not right, adjust by using the disk 
magnets. 
a
b
b
c
c
d
d
a
Purity control
corrects this area.
Disc magnets or rotatable
disc magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
 5. 
Oscilloscope
 6. 
Landing 
Checker
 7. 
XCV 
Adjuster
KV-29FS150
KV-29FS150 
14
2-2. CONVERGENCE
Before starting convergence adjustments:
1 Perform 
FOCUS 
adjustments.
2.  Set Picture mode to “CUSTOM”.
3.  Feed in dot pattern.
Vertical Static Convergence
1.  Adjust the 4 pole magnet to converge red, green and blue dots in 
the center of the screen. 
4 pole magnet
RV750
H. STAT
RV1800
G2 (SCREEN) 
Center dot
R     G     B
G
R
B
2.  Tilt the 4 pole magnet and adjust static convergence to open or 
close the 4 pole magnet.
3.  When the 4 pole magnet is moved in the direction of arrow 
A
 and 
B
, the red, green, and blue dots move as shown below:
Moved RV750 (H.STAT)
R
R
G
G
B
B
A
A
B
B
B
B
R
G
G
R
B
Horizontal Static Convergence
If the blue dot does not converge with the red and green dots, use the 6 
pole magnet to adjust as shown:
R G
B
R
G
B
R
G B
R
B
R
G
G
G
B
R
B
6 Pole Magnet
4 pole Magnet
DY pocket
Purity
6 Pole
Magnet
4 Pole
Magnet
Y Separation Axix Correction Magnet 
Adjustment
1.  Input cross hatch pattern.
2.  Set Picture to “MINIMUM”, Brightness to ‘STANDARD”.
3.  Adjust the Y separation axis correction magnet on the Neck 
Assembly so that the horizontal lines at the top and bottom of the 
screen are straight.
Red
Blue
Red
Blue
KV-29FS150
KV-29FS150 
15
Convergence Rough Adjustment
Before performing this adjustment, perform Horizontal and Vertical Static 
Convergence Adjustment.
Input cross hatch pattern.
 a) 
 
TLH
 
Adjust the horizontal convergence of red and blue dots by inserting 
TLH Correction Plate to the DY pocket (left or right).
 b) 
 
YCH
 
Adjust YCH to balance Y axis.
 c) 
 
TLV
 
Adjust the vertical convergence of red and blue dots.
 d) 
 
XCV
 
Adjust XCV to balance X-axis.
TLV
R B
YCH
R
B
XCV
B
R
TLH
B
R
(VR1)
TLV1 (no need to adjust)
DY pocket
DY pocket
TLH Plate
(VR3)
TLV2
(XCV)
(VR2)
YCH
ON DY :
Screen Corner Convergence
Affi x a Piece A (110), Convergence Correct/Permaloy Assy Correction to 
the misconverged areas. 
b
a
c
d
a-d : screen-corner
        misconvergence
a1
b1
c1
d1
a1~d1: Piece A(110), Convergence Correct
or
Permaloy Assy Correction
2-3. FOCUS ADJUSTMENT
FOCUS adjustment should be completed before White Balance 
adjustment. (See 3-4. WHITE BALANCE ADJUSTMENT)
1.  Receive digital monoscope pattern.
2.  Set Picture Mode to “STANDARD”.
3.  Adjust focus VR to obtain a just focus at the center of the screen.
4.  Change the receiving signal to white pattern and blue back.
5.  Confi rm magenta ring is not noticeable. In case magenta ring is 
obvious, then adjust FOCUS VR to balance magenta ring and 
FOCUS.
FLYBACK TRANSFORMER  (T503)
KV-29FS150
KV-29FS150 
16
2-4. SCREEN (G2)
1.  Before beginning adustment procedure:
 
-Set Picture and Brightness to “STANDARD”.
 
-Set TV to Video mode.
 
-Set WHBL 016 “RGBB” to 01
2.  Connect R, G, B of the CV board cathode to oscilloscope.
3.  Adjust Brightness to obtain the cathode value to the value shown 
below:
Cathode setting voltage:
170 V 
± 2 (VDC)
4.  Adjust SCREEN VR on the FBT until the scanning line disappears.
5.  Set WHBL 16 “RGBB” back to 00.