KV-29FS150
KV-29FS150 
5
WARNINGS AND CAUTIONS
CAUTION
Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield, or carbon painted on the CRT, after 
removing the anode.
WARNING!!
An isolation transformer should be used during any service to avoid possible shock hazard, because of live chassis. The chassis of this 
receiver is directly connected to the AC power line.
!
 SAFETY-RELATED COMPONENT WARNING!!
Components identifi ed by shading and ! mark on the schematic diagrams, exploded views, and in the parts list are critical for safe 
operation. Replace these components with Sony parts whose part numbers appear as shown in this manual or in supplements published 
by Sony.  Circuit adjustments that are critical for safe operation are identifi ed in this manual. Follow these procedures whenever critical 
components are replaced or improper operation is suspected. 
KV-29FS150
KV-29FS150 
6
SAFETY CHECK-OUT
After correcting the original service problem, perform the following 
safety checks before releasing the set to the customer:
1.  Check the area of your repair for unsoldered or poorly soldered 
connections. Check the entire board surface for solder splashes and 
bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” or 
touching high-wattage resistors.
3.  Check that all control knobs, shields, covers, ground straps, and 
mounting hardware have been replaced. Be absolutely certain that 
you have replaced all the insulators.
4.  Look for unauthorized replacement parts, particularly transistors, 
that were installed during a previous repair. Point them out to the 
customer and recommend their replacement.
5.  Look for parts which, though functioning, show obvious signs of 
deterioration. Point them out to the customer and recommend their 
replacement.
6.  Check the line cords for cracks and abrasion. Recommend the 
replacement of any such line cord to the customer.
7.  Check the B+ and HV to see if they are specifi ed values. Make sure 
your instruments are accurate; be suspicious of your HV meter if 
sets always have low HV.
8.  Check the antenna terminals, metal trim, “metallized” knobs, 
screws, and all other exposed metal parts for AC leakage. Check 
leakage as described below.
Leakage Test
The AC leakage from any exposed metal part to earth ground and from 
all exposed metal parts to any exposed metal part having a return to 
chassis, must not exceed 0.5 mA (500 microamperes). Leakage current 
can be measured by any one of three methods.
1.  A commercial leakage tester, such as the Simpson 229 or RCA 
WT-540A. Follow the manufacturers’ instructions to use these 
instructions.
2.  A battery-operated AC milliampmeter. The Data Precision 245 
digital multimeter is suitable for this job.
3.  Measuring the voltage drop across a resistor by means of a VOM 
or battery-operated AC voltmeter. The “limit” indication is 0.75 V, 
so analog meters must have an accurate low voltage scale. The 
Simpson’s 250 and Sanwa SH-63TRD are examples of passive 
VOMs that are suitable. Nearly all battery-operated digital 
multimeters that have a 2 VAC range are suitable (see Figure A).
How to Find a Good Earth Ground
A cold-water pipe is a guaranteed earth ground; the cover-plate 
retaining screw on most AC outlet boxes is also at earth ground. If the 
retaining screw is to be used as your earth ground, verify that it is at 
ground by measuring the resistance between it and a cold-water pipe 
with an ohmmeter. The reading should be zero ohms.
If a cold-water pipe is not accessible, connect a 60- to 100-watt trouble- 
light (not a neon lamp) between the hot side of the receptacle and the 
retaining screw. Try both slots, if necessary, to locate the hot side on 
the line; the lamp should light at normal brilliance if the screw is at 
ground potential (see Figure B).
To Exposed Metal 
Parts on Set
0.15 µF
1.5 K 
AC
Voltmeter
(0.75 V)
Earth Ground
Trouble Light
AC Outlet Box
Ohmmeter
Cold-water Pipe
Figure A. Using an AC voltmeter to check AC leakage.
Figure B. Checking for earth ground.
KV-29FS150
KV-29FS150 
7
SELF-DIAGNOSTIC FUNCTION
 
*One fl ash count is not used for self-diagnostic.
*If a +B overcurrent is detected, stoppage of the vertical defl ection is detected simultaneously.  The symptom that is diagnosed fi rst by the mircrocontroller 
is displayed on the screen.
**Refer to Screen (G2) Adjustments in Section 2-4. of this manual.
2. Display of STANDBY LED Flash Count
2 times
4 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
 
Standby indicator
Self Diagnosis
Supported model
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY LED indicator will automatically begin to fl ash. The number of 
times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY LED fl ash indicators is listed in the instruction manual 
for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review the failure occurrence 
data stored in memory to reveal past problems and how often these problems occur.
1. Diagnostic Test Indicators
When an error occurs, the STANDBY LED indicator will fl ash a set number of times to indicate the possible cause of the problem. If there is more than 
one error, the indicator will identify the fi rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen.  No error has occurred if the screen displays a “0”.
Diagnosis
Item
Description
• No Power
• +B overcurrent
(OCP)
• Vertical NG.
• IK (AKB)
• Supply Voltage
Protection
Detected
Symptoms
• Power does not turn on.
• No power is supplied to the
TV.
• AC power supply is faulty.
• Power does not turn on.
• Load on power line is
shorted.
• Has entered standby state
after horizontal raster.
• Vertical deflection pulse is
stopped.
• Power line is shorted or
power supply is stopped.
• No raster is generated.
• CRT cathode current
detection reference pulse
output is small.
• No power supply to CRT
ANODE.
• No RASTER is generated.
No. of times
STANDBY
Indicator flashes
Does not light
2 times
4 times
5 times
8 times
Diagnostic Result
on screen display
2 OCP:0
2 OCP:1 ~ 255
4 VSTOP:0
4 VSTOP:1 ~ 255
5 AKB:0
5 AKB:1 ~ 255
8 SUP:0
8 SUP:1 ~ 255
Probable
Cause
Location
• Power cord is not plugged
in.
• Fuse is burned out (F4101)
(H2 Board)
• H.OUT (Q511) is shorted.
(A board)
• IC751 is shorted.
(CV Board)
• +13V is not supplied.
(A Board)
• IC503 voltage list is faulty.
(A Board)
• Video OUT (IC751) is faulty.
(CV Board)
• IC001 is faulty. (A Board)
• Screen (G2) is improperly
adjusted.
• IC604 faulty.
• IC607 faulty.
KV-29FS150
KV-29FS150 
8
3. Stopping the STANDBY LED Indicator Flash
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY LED Indicator from fl ashing.
4. Self-Diagnostic Screen Display
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confi rmed, it is possible to bring up past 
occurrences of failure on the screen for confi rmation.
To Bring Up Screen Test
In standby mode, press buttons on the Remote Commander sequentially, in rapid succession, as shown below:
 
DISPLAY
  
 Channel  5      
 Sound Volume  -  
 
 POWER
 
 
Note that this differs from entering the Service Mode (Sound Volume  +  ).
The following screen will be displayed indicating the error count:
 
SELF DIAGNOSTIC
2 OCP 
: 0
3 OVP 
N/A
4 VSTOP  : 
Number “0” means that no fault was detected.
5 AKB 
Number “1” means a fault was detected one time only.
8 SUP 
 
0
101 WDT 
 N/A
SERIAL:   FFFFFFF
MODEL: FFFFFFFF
Handling of Self-Diagnostic Screen Display
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen during repairs. When you 
have completed the repairs, clear the result display to “0”.
Unless the result display is cleared to “0”, the self-diagnostic function will not be able to detect subsequent faults after completion of the repairs.
Clearing the Result Display
To clear the result display to “0”, press buttons on the Remote Commander sequentially when the diagnostic screen is displayed, as shown below:
Channel  8  
  0
Quitting the Self-Diagnostic Screen
To quit the entire self-diagnostic screen, turn off the power switch on the Remote Commander or the main unit.
Page of 85