DOWNLOAD Sony KP-FX432M31 / KP-FX432M91 / KP-FX532M91 Service Manual ↓ Size: 14.61 MB | Pages: 127 in PDF or view online for FREE

Model
KP-FX432M31 KP-FX432M91 KP-FX532M91
Pages
127
Size
14.61 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kp-fx432m31-kp-fx432m91-kp-fx532m91.pdf
Date

Sony KP-FX432M31 / KP-FX432M91 / KP-FX532M91 Service Manual ▷ View online

– 21 –
KP-FX432M31/FX432M91/FX532M91
RM-998
RM-998
RM-998
3-9. SERVICE LIST
Category
Item
Function
Standard Data
Device Name
No.
Name
(Slave Address)
OSD
0
OSV
OSD V Position
32
CXP961F064(60H)
1
OSH
OSD H Position
13
2
FW1
OSD ODD/EVEN Field Window Setup #1
7
3
FW2
OSD ODD/EVEN Field Window Setup #2
20
4
VOF
OSD V Position (Offset)
*1
OSD: Standard Data *1
Item
Standard Data
No.
Name
OSD V OFFSET
HD50
HD60
VCOMP
VCOMP60
VCOMP100
VCOMP120
4
VOF
32
32
32
32
32
32
OSD: Standard Data *1
Item
Standard Data
No.
Name
OSD V OFFSET
FULL50
FULL60
FULL100
FULL120
4
VOF
32
32
16
16
Note
  : The data value of each mode. Other are set up by each mode.
  : Shaded items are fixed data.
  : Though data value is indicated on the screen, it is not used.
Standard data listed on the Adjustment Item Table are reference valies, therefore it may be different for each model and each mode.
Note for Different Data :
Those are the standard data values written on the microprocessor. Therefore , the data values of the modes and stored respectively in the memory.
In case of a device replacement, adjustment by rewriting the data value is necessary for some items.
 22 
KP-FX432M31/FX432M91/FX532M91
RM-998
RM-998
RM-998
Category
Item
Function
Standard Data
Device Name
No.
Name
(Slave Address)
MSP
0
WST
W/G Stereo Threshold
21
MSP3415D(84H)
1
WBT
W/G Bilingual Threshold
236
2
WLL
W/G Monaural Threshold
5
3
WAC
W/G Agreement Count
1
4
WDL
W/G Search Delay
48
5
NDL
NICAM Search Delay
32
6
SDL
Stereo status Read Delay
16
7
AGC
AGC Switch Auto/Constant
1
8
REL
AGC Gain at Constant Mode
40
9
CRM
Carrier muting on/off
0
10
ACO
Audio Clock out on/off
1
11
FP
FM Prescale for non-M system
27
12
FPM
FM Prescale for M system
50
13
FH
FM Prescale for HDEV
54
14
FHM
FM Prescale for HDEV and M
101
15
WGP
W/G Prescale
28
16
NIP
NICAM Prescale
127
17
ERR
Auto FM switch Threshold
80
18
VOL
Loud Speaker gain 0700h to 07FFh
48
 23 
KP-FX432M31/FX432M91/FX532M91
RM-998
RM-998
RM-998
Category
Item
Function
Standard Data
Device Name
No.
Name
(Slave Address)
PIC
0
PIC
User Picture
*1
PFED-PICTURE
1
COL
User Color
*1
2
BRI
User Bright
*1
3
HUE
User Hue
*1
4
SHP
User Sharp
*1
5
PIOF
Picture Offset (Picture * (20-data)/20 * Eco(75%)
*1
PIC: Standard Data *1
Item
Standard Data
No.
Name
Picture/
Picture Offset
Sound Mode Table
Dynamic
Standard/
Hi-Fine/Soft
Personal
Normal(4:3)
HD
Other
Drama
0
PIC
100
70
60
50
1
COL
60
55
50
50
2
BRI
45
50
50
50
3
HUE
50
50
50
50
4
SHP
45
50
50
50
5
PIOF
2
2
0
Category
Item
Function
Standard Data
No.
Name
Picture/
Device Name
Sound Mode Table
Dynamic
Standard/
Hi-Fine/Soft
Personal
(Slave Address)
Drama
SOU
0
BAS
User Bass
74
50
50
50
PFED-SOUND
1
TRE
User Treble
50
50
42
50
Category
Item
Function
Standard Data
Device Name
No.
Name
(Slave Address)
PFED
0
PFED
PF-Engine Service
*
Pf-Engine
Category
Item
Function
Standard Data
Device Name
No.
Name
(Slave Address)
GUID
0
GUID
Guide Select country ID (0:English,1:Tiwan,2:Korea,3:English)
0
Category
Item
Function
Standard Data
Device Name
No.
Name
(Slave Address)
POWR
0
DLY1
Power On Delay1
4
1
DLY2
Power On Delay2
0
2
DLY3
Power On Delay3
4
3
ZDET
Zero Detect Delay
31
4
ZTMO
Zero Detect Timeout (*10ms min 300ms)
30
 24 
KP-FX432M31/FX432M91/FX532M91
RM-998
RM-998
RM-998
Category
Item
Function
Standard Data
No.
Name
OPM
0
APC
APC Switch
1
1
TSY
TV System Selection under searching with Auto TV System
2
2
AFM
Auto FM switch
1
3
DBL
Disable Blueback function
1
4
SSO
Speed CH Search Selection
1
5
SCH
CH Selection for Shipping Condition
1
6
SCA
Cable/Air Selection for Shipping Condition
1
7
DMG
Disable Menu-operation Guide
0
8
VSN
Enable Noise Reduction in Video Mode
0
9
LBB
Lower Blue Back Intensity
1
10
23P
2/3 Pull Down Mode 0: Force OFF, 1: Auto
1
11
DF
DF_PHA
31
12
DQP
DQP_PHA
31
13
VLIM
Wide V-Center Limit
15
14
TUT1
Tune Wait Time Mode1 (Max) 30[ms] + 10[ms] * service_data
8
15
TUT2
Tune Wait Time Mode2 (Max) 30[ms] + 10[ms] * service_data
5
16
TUT3
Tune Wait Time Mode3 (Max) 30[ms] + 10[ms] * service_data
2
17
TUTW
Tune Wait Time 6 point sense
5
18
3NR
3D-NR INIT (User Reset or Test Reset)
1
19
SIG
No-Signal Detect number of lock detect count.
*1
20
NSIG
No-Signal Detect number of unlock detect counter.
*1
Category
Item
Function
Standard Data
Device Name
No.
Name
(Slave Address)
OPB
0
OP0
Optional Bits 0
60
Option-Bits
1
OP1
Optional Bits 1
75
2
OP2
Optional Bits 2
3
3
OP3
Optional Bits 3
8
4
OP4
Optional Bits 4
13
Category
Item
Function
Standard Data
Device Name
No.
Name
(Slave Address)
SRV
0
COM
Service Command
*
OPM: Standard Data *1
Item
Standard Data
No.
Name
Signa-Detect
RF
Video
19
SIG
0
0
20
NSIG
0
0
Page of 127
Display