— 6 —
KP-57WV600/57WV700/
65WV600/65WV700
SAFETY CHECK-OUT
After correcting the original service problem, perform the following 
safety checks before releasing the set to the customer:
1.  Check the area of your repair for unsoldered or poorly soldered 
connections. Check the entire board surface for solder splashes and 
bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” or 
touching high-wattage resistors.
3.  Check that all control knobs, shields, covers, ground straps, and 
mounting hardware have been replaced. Be absolutely certain that 
you have replaced all the insulators.
4.  Look for unauthorized replacement parts, particularly transistors, 
that were installed during a previous repair. Point them out to the 
customer and recommend their replacement.
5.  Look for parts which, though functioning, show obvious signs of 
deterioration. Point them out to the customer and recommend their 
replacement.
6.  Check the line cords for cracks and abrasion. Recommend the 
replacement of any such line cord to the customer.
7.  Check the B+ and HV to see if they are specifi ed values. Make sure 
your instruments are accurate; be suspicious of your HV meter if sets 
always have low HV.
8.  Check the antenna terminals, metal trim, “metallized” knobs, screws, 
and all other exposed metal parts for AC leakage. Check leakage 
as described below.
Leakage Test
The AC leakage from any exposed metal part to earth ground and from 
all exposed metal parts to any exposed metal part having a return to 
chassis, must not exceed 0.5 mA (500 microamperes). Leakage current 
can be measured by any one of three methods.
1.  A commercial leakage tester, such as the Simpson 229 or 
RCA WT-540A. Follow the manufacturers’ instructions to use these 
instructions.
2.  A battery-operated AC milliammeter. The Data Precision 245 digital 
multimeter is suitable for this job.
3.  Measuring the voltage drop across a resistor by means of a VOM 
or battery-operated AC voltmeter. The “limit” indication is 0.75 V, 
so analog meters must have an accurate low voltage scale. The 
Simpson’s 250 and Sanwa SH-63TRD are examples of passive 
VOMs that are suitable. Nearly all battery-operated digital multimeters 
that have a 2 VAC range are suitable (see Figure A).
How to Find a Good Earth Ground
A cold-water pipe is a guaranteed earth ground; the cover-plate retaining 
screw on most AC outlet boxes is also at earth ground. If the retaining 
screw is to be used as your earth ground, verify that it is at ground 
by measuring the resistance between it and a cold-water pipe with an 
ohmmeter. The reading should be zero ohms.
If a cold-water pipe is not accessible, connect a 60- to 100-watt trouble- 
light (not a neon lamp) between the hot side of the receptacle and the 
retaining screw. Try both slots, if necessary, to locate the hot side on the 
line; the lamp should light at normal brilliance if the screw is at ground 
potential (see Figure B).
Trouble Light
AC Outlet Box
Ohmmeter
Cold-water Pipe
Figure A. Using an AC voltmeter to check AC leakage.
Figure B. Checking for earth ground.
To Exposed Metal
 Parts on Set
AC Voltmeter
(0.75 V)
Earth Ground
0.15 
µ
F
1.5 
k
— 7 —
KP-57WV600/57WV700/
65WV600/65WV700
SELF-DIAGNOSTIC FUNCTION
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to ß ash. The number 
of times the LED ß ashes translates to a probable source of the problem. A deÞ nition of the STANDBY/TIMER LED ß ash indicators is listed in the 
instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review 
the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will ß ash a set number of times to indicate the possible cause of the problem. If there is more than 
one error, the LED will identify the Þ rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. If the screen displays a “0”, no error has occurred.
Diagnostic Item
No. of times
STANDBY /
TIMER lamp
flashes
Display
Result
Probable Cause Location
Detected Symptoms
Power does not turn on
Does not light
_______
Power cord is not plugged in.
Fuse is burned out (F501). (A Board)
Power does not come on.
No power is supplied to the TV.
AC Power supply is faulty.
+B Overcurrent (OCP)*
2 times
2:0 or 2:1
H.OUT(Q8024) is shorted. (D Board)
+B PWM (Q8035) is shorted.
(D Board)
Power does not come on.
Load on power line shorted.
Low +B Overvoltage (OVP)
3 times
3:0 or 3:1
IC6504 is faulty. (D Board)
Has entered standby mode.
Vertical Deflection Stopped
4 times
4:0 or 4:1
15V is not supplied. (D Board)
IC8003 is faulty. (D Board)
Has entered standby mode after
Horizontal raster.
Vertical deflection pulse is stopped.
Power line is shorted or power
supply is stopped.
White Balance Failure
(not balanced)
5 times
5:0 or 5:1
Video OUT(IC9101, IC9201, IC9301)
is faulty. (CR, CG, CB Board)
CRTdrive (IC2801) is faulty. (B Board)
G2 is improperly adjusted.**
No raster is generated.
CRTcathode current detection
reference pulse output is small.
LOW +B OCP/OVP
(overcurrent/overvoltage)***
6 times
6:0 or 6:1
+5 line is overloaded. (A, B, M Boards)
+5 line is shorted. (A, B, M Boards)
IC504 is faulty. (A Board)
No picture
Horizontal Deflection
Stopped
7 times
7:0 or 7:1
No picture
* If a +B overcurrent is detected, stoppage of the vertical deflection is detected simultaneously. The symptom that is diagnosed first by the
microcontroller is displayed on the screen.
** Refer to Screen (G2) Adjustment (Fine Adjustments) in Section 2 of this manual.
*** If STANDBY/STEREO LED flashes six (6) times, unplug the unit and wait 10 seconds before performing the adjustment.
Self Diagnosis
Supported model
— 8 —
KP-57WV600/57WV700/
65WV600/65WV700
Display of Standby/Timer LED Flash Count
STAND BY Indicator
TIMER Indicator
POWER
STAND BY
TIMER
CHANNEL
Diagnostic items 
Flash count
Lamp OFF 3 sec.
Lamp ON 0.3 sec.
Lamp OFF 0.3 sec.
+B Overcurrent 
2 times
Low +B Overvoltage 
3 times
Vert. Deflection Stopped 
4 times
White Balance Failure 
5 times
Low +B OCP/OVP 
6 times
Horiz. Deflection Stopped 
7 times
Release of TIMER STAND BY indicator blinking
The TIMER/STANDBY indicator blinking display is released by turning OFF the power switch on the TV main unit or removing the plug from the 
power.
Self-Diagnosis Screen Displays
In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when the screen 
disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether the detection circuit operated 
or not) in order to allow conÞ rmation.
      
Screen Display Method
Quickly press the remote command button in the following order from the standby state.
  Display  
  Channel  5   
  Sound Volume* 
_
  
  Power ON 
 
 
 
 
 
*Note that this differs from entering the service mode (sound volume  +  )
 
 SELF DIAGNOSIS
 2: +B OCP  
0
 3: +B OVP  
0
 4: VSTOP  
0
 5: AKB   
1
 6: LOWB   
0
 7: H-STOP  
0
 101: WDT  
24
Self-Diagnosis Screen Display
The results display is not automatically cleared.  In case of repairs and after repairs, check the self-diagnosis screen and be sure to return the 
results display to “ 0 ”. 
If the results display is not returned to “ 0 ” it will not be possible to judge a new malfunction after completing repairs.
Method of Clearing Results Display
1.  Power off (Set to the stanby mode.)
2.   Display  
  Channel  5   
  Sound Volume  +   
  Power ON (Service Mode) 
3.  Channel  8   
   ENTER  (Test reset = Factory preset condition)
Method of Ending Self Diagnosis Screen
When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main unit.
Numeral “0” 
means that no fault was detected.
Numeral “1” 
means a fault was detected one 
time only.
— 9 —
KP-57WV600/57WV700/
65WV600/65WV700
Self-Diagnosis Function Operation
+B overcurrent (OCP) 
Occurs when excessive current ß ows through R5013. The increase in voltage across R5013 causes the output of Q5004 to go high, and this high 
signal goes to the micro. 
+B overvoltage (OVP) 
IC6505 detects +B OVP condition and turns on Q6522. This sends a high signal to the micro and also shuts down the AC relay.
V-STOP 
Occurs when an absence of the vertical deß ection pulse is detected by pin 24 of IC2801 (B Board). Power supply will shut down when waveform 
interval exceeds 2 seconds. 
White Balance Failure
If the RGB levels* do not balance within 2 seconds after the power is turned on, this error will be detected by IC2801. TV will stay on, but there 
will be no picture.
*(Refers to the RGB levels of the AKB detection Ref pulse that detects 1K).
Low B OCP/OVP
Occurs when set 5V is out.
Horizontal Deß ection Stopped
Occurs when either: 
 
1) a +B overcurrent is detected (IC5007), or 
 
2) overheating is detected (Thermistor TH5002).
Self-Diagnosis Block Diagram
1
2
4
3
3
1
2
R5104
R5105
R5125
Q5018
RY6501
Q6527
Q6530
Q6532
D6537
D6505
D5007
PH6501
Q5004
R5013
D5005
IC6505
Q6522
1K-PROT2
+B OVP
HV PROT
UNREG 11V
5V
UNREG 7V
+B OCP
2
1
3
4
IC5007
VDY-
CRT
IC2801
Y/C JUNGLE
SCL
SDA
AKB
VPROT
HPROT
IC2300
MAIN MICRO
M
CLKO
DATO
AC RLY
LOW B ERR
OVP
OCP
STR
STBY-LED
STBY-LED
P_SW(-)
IC504
5V
+B
+B
+B
D
B
M
D
D
A
2
14
34
35
58
26
25
29
30
69
43
44
45
48
O
I
O
Page of 127