DOWNLOAD Sony KE-37XS910 / KE-42XS910 / KE-MX37A1 / KE-MX37N1 / KE-MX37S1 Service Manual ↓ Size: 3.46 MB | Pages: 88 in PDF or view online for FREE

Model
KE-37XS910 KE-42XS910 KE-MX37A1 KE-MX37N1 KE-MX37S1
Pages
88
Size
3.46 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / PANEL MODULE
File
ke-37xs910-ke-42xs910-ke-mx37a1-ke-mx37n1-ke-mx37s.pdf
Date

Sony KE-37XS910 / KE-42XS910 / KE-MX37A1 / KE-MX37N1 / KE-MX37S1 Service Manual ▷ View online

 
– 73 –
 
(4) To change the internal pattern, select the internal pattern selection from the POWER ON 
menu using the ↑(up) or ↓(down) key, and press the <ENTER> key. 
Setup 
value 
Display pattern 
Setup 
value 
Display pattern 
00 
01 to 08 patterns are displayed 
every 2 seconds.   
05 
Entire screen is cyan 
01 
Entire screen is blue 
06 
Entire screen is yellow 
02 
Entire screen is red 
07 
Entire screen is white 
03 
Entire screen is magenta 
08 
Entire screen is black 
04 
Entire screen is green 
F6 
Plant burn-in pattern 
From the POWER ON menu, select Burn-in start with the ↑ key or ↓ key 
  and press the <ENTER> key. The display pattern is automatically generated in PDP. 
 
(6) Select RETURN with ↑ key or ↓ key and press <ENTER> key to return to the menu screen.   
 
– 74 –
 
6.2.5 
Logic board parameter forwarding 
(1) The module is set according to the same to failure analysis procedure in clause 4.7. 
The logic board before being exchanged is installed in the module. 
(2) From the main menu, select change Logic board menu with the ↑ key or ↓ key and press 
the <ENTER> key. 
 
(3) From the logic board change menu, select data copy with the ↑ key or ↓ key and press the 
<ENTER> key. Data is read before the Logic board is exchanged. 
 
 
(4) The Logic board is exchanged. 
 
 
– 75 –
 
(5) From the logic board change menu, select data paste with the ↑ key or ↓ key and press the 
<ENTER> key. Data is written in the exchanged Logic board. 
 
 
(6) Select RETURN with ↑ key or ↓ key and press <ENTER> key to return to the menu screen. 
 
 
 
– 76 –
 
6.2.6 
Accumulation time reset 
(1) The module is set according to the same to failure analysis procedure in clause 4.7. 
(2) From the main menu, select Power-on time menu with the ↑ key or ↓ key and press the 
<ENTER> key. 
 
(3) From the Power-on time menu, select Operation hours with the ↑ key or ↓ key and press 
the <ENTER> key. The Operation hour is input. *It is not possible to change in the 
energizing time according to the version of the service software. 
 
 
(4) "minute" is continuously input and < ENTER > key is pushed.   
(5) "Second" is continuously input and < ENTER > key is pushed. 
(6) Select RETURN with ↑key or ↓key and press <ENTER> key to return to the menu screen. 
 
 
Page of 88
Display

Click on the first or last page to see other KE-37XS910 / KE-42XS910 / KE-MX37A1 / KE-MX37N1 / KE-MX37S1 service manuals if exist.