Sony DPP-MS300 / DPP-MS300E Service Manual ▷ View online
– 2 –
Sony Corporation
Printing Technologies Company
9-928-127-91
99F05550-1
Printed in Japan © 1999. 6
Published by VAIO Customer Link
Page
INCORRECT
CORRECT
4-3
DPP-MS300 (US, Canadian models)
%
%
%
%
%
Page
INCORRECT
CORRECT
4-3
DPP-MS300E (AEP, UK models)
%
%
%
%
Note 2:
To print the stair-step test pattern, turn on the power switch while
pressing the S1707 (CAPTURE) and S1717 (ENTER) on the SW-
40 board.
(Press the S1707 (CAPTURE) and S1717 (ENTER) until a peep
is heard.) Set the S1701 (Rotaly switch) to the position, and
press the S1706 (print), then the print will start.
pressing the S1707 (CAPTURE) and S1717 (ENTER) on the SW-
40 board.
(Press the S1707 (CAPTURE) and S1717 (ENTER) until a peep
is heard.) Set the S1701 (Rotaly switch) to the position, and
press the S1706 (print), then the print will start.
Note 1:
To print the stair-step test pattern, turn on the power switch while
pressing the S1707 (CAPTURE) and S1717 (ENTER) on the SW-
40 board.
(Press the S1707 (CAPTURE) and S1717 (ENTER) until a peep
is heard.) Set the S1701 (Rotaly switch) to the position, and
press the S1706 (print), then the print will start.
pressing the S1707 (CAPTURE) and S1717 (ENTER) on the SW-
40 board.
(Press the S1707 (CAPTURE) and S1717 (ENTER) until a peep
is heard.) Set the S1701 (Rotaly switch) to the position, and
press the S1706 (print), then the print will start.
Adjustment Procedure:
(1)
(1)
To print the stair-step test pattern, turn on the power switch
while pressing the S1707 (CAPTURE) and S1717 (ENTER)
on the SW-40 board.
(Press the S1707 (CAPTURE) and S1717 (ENTER) until a
peep is heard.) Set the S1701 (Rotaly switch) to the posi-
tion, and press the S1706 (print), then the print will start.
while pressing the S1707 (CAPTURE) and S1717 (ENTER)
on the SW-40 board.
(Press the S1707 (CAPTURE) and S1717 (ENTER) until a
peep is heard.) Set the S1701 (Rotaly switch) to the posi-
tion, and press the S1706 (print), then the print will start.
Mode
Test mode (Note 1)
Signal
Test pattern (Stair-step)
Measuring points
+: CN1943 2 pin (MD-40 board)
–: CN1943 3 pin
–: CN1943 3 pin
Measuring instrument
Digital Voltmerter
Adjustment part
VR201
Specification
Print density should be the same as the sample
Note 2:
To print the stair-step test pattern, turn on the power switch while
pressing the S1714 (SAVE) and S1717 (ENTER) on the SW-40
board.
(Press the S1714 (SAVE) and S1717 (ENTER) until a peep is
heard.) Set the S1701 (Rotaly switch) to the
pressing the S1714 (SAVE) and S1717 (ENTER) on the SW-40
board.
(Press the S1714 (SAVE) and S1717 (ENTER) until a peep is
heard.) Set the S1701 (Rotaly switch) to the
position, and
press the S1706 (print), then the print will start.
Adjustment Procedure:
(1)
(1)
To print the stair-step test pattern, turn on the power switch
while pressing the S1714 (SAVE) and S1717 (ENTER) on
the SW-40 board.
(Press the S1714 (SAVE) and S1717 (ENTER) until a peep
is heard.) Set the S1701 (Rotaly switch) to the position,
and press the S1706 (print), then the print will start.
while pressing the S1714 (SAVE) and S1717 (ENTER) on
the SW-40 board.
(Press the S1714 (SAVE) and S1717 (ENTER) until a peep
is heard.) Set the S1701 (Rotaly switch) to the position,
and press the S1706 (print), then the print will start.
Mode
Test mode (Note 1)
Signal
Test pattern (Stair-step)
Measuring points
+: CN1943 2 pin (MD-40 board)
–: CN1943 3 pin
–: CN1943 3 pin
Measuring instrument
Digital Voltmerter
Adjustment part
VR201
Specification
Print density should be the same as the sample
Note 2:
To print the stair-step test pattern, turn on the power switch while
pressing the S1707 (CAPTURE) and S1717 (ENTER) on the SW-
40 board.
(Press the S1707 (CAPTURE) and S1717 (ENTER) until a peep
is heard.) Set the S1701 (Rotaly switch) to the position, and
press the S1706 (print), then the print will start.
pressing the S1707 (CAPTURE) and S1717 (ENTER) on the SW-
40 board.
(Press the S1707 (CAPTURE) and S1717 (ENTER) until a peep
is heard.) Set the S1701 (Rotaly switch) to the position, and
press the S1706 (print), then the print will start.
Adjustment Procedure:
(1)
(1)
To print the stair-step test pattern, turn on the power switch
while pressing the S1707 (CAPTURE) and S1717 (ENTER)
on the SW-40 board.
(Press the S1707 (CAPTURE) and S1717 (ENTER) until a
peep is heard.) Set the S1701 (Rotaly switch) to the posi-
tion, and press the S1706 (print), then the print will start.
while pressing the S1707 (CAPTURE) and S1717 (ENTER)
on the SW-40 board.
(Press the S1707 (CAPTURE) and S1717 (ENTER) until a
peep is heard.) Set the S1701 (Rotaly switch) to the posi-
tion, and press the S1706 (print), then the print will start.
Mode
Test mode (Note 2)
Signal
Test pattern (Stair-step)
Measuring points
+: CN1943 2 pin (MD-40 board)
–: CN1943 3 pin
–: CN1943 3 pin
Measuring instrument
Digital Voltmerter
Adjustment part
VR201
Specification
Print density should be the same as the sample
Note 2:
To print the stair-step test pattern, turn on the power switch while
pressing the S1714 (SAVE) and S1717 (ENTER) on the SW-40
board.
(Press the S1714 (SAVE) and S1717 (ENTER) until a peep is
heard.) Set the S1701 (Rotaly switch) to the
pressing the S1714 (SAVE) and S1717 (ENTER) on the SW-40
board.
(Press the S1714 (SAVE) and S1717 (ENTER) until a peep is
heard.) Set the S1701 (Rotaly switch) to the
position, and
press the S1706 (print), then the print will start.
Adjustment Procedure:
(1)
(1)
To print the stair-step test pattern, turn on the power switch
while pressing the S1714 (SAVE) and S1717 (ENTER) on
the SW-40 board.
(Press the S1714 (SAVE) and S1717 (ENTER) until a peep
is heard.) Set the S1701 (Rotaly switch) to the position,
and press the S1706 (print), then the print will start.
while pressing the S1714 (SAVE) and S1717 (ENTER) on
the SW-40 board.
(Press the S1714 (SAVE) and S1717 (ENTER) until a peep
is heard.) Set the S1701 (Rotaly switch) to the position,
and press the S1706 (print), then the print will start.
Mode
Test mode (Note 2)
Signal
Test pattern (Stair-step)
Measuring points
+: CN1943 2 pin (MD-40 board)
–: CN1943 3 pin
–: CN1943 3 pin
Measuring instrument
Digital Voltmerter
Adjustment part
VR201
Specification
Print density should be the same as the sample
DPP-MS300/DPP-MS300E
Display