– 49 –
 
(2) Check the error code (hexadecimal number) from the Latest error code read-out menu and 
locate the faulty position from the following table. 
 
Example of displaying breakdown analysis 
 
 
(3) Select RETURN using the ↑key or ↓key and press <ENTER> key to start the program, then 
the screen returns to the menu screen.   
* When EXIT is selected, the screen returns to the WINDOWS or DOS screen.   
 
The latest error code 
A past error code is shown 
in new the order. 
All error code is cleared to 0. 
The state of the module 
 
– 50 –
 
Error code table
 
Suspected faulty board   
(In the order of higher probability of defect) 
ERR 
code 
Detect 
position 
(board) 
Contents 
(1) 
(2) 
(3) 
(4) 
(5) 
(6) 
(7) 
Remarks 
00 
LOGIC 
STANDBY 
power 
is 
stopped PSU 
      PSU 
temperature has 
probably  
increased 
04 
3.3V power voltage has dropped 
LOGIC  PSU 
 
 
 
 
 
 
06 
3.3V power startup is faulty 
X-SUS  Y-SUS  ADM1-8  PSU 
ABUS-L  ABUS-R  LOGIC   
08 
1V 
power 
voltage 
has 
dropped 
LOGIC 
PSU 
      
0A 
1V power startup is faulty 
X-SUS  Y-SUS  ADM1-8  PSU 
ABUS-L  ABUS-R  LOGIC   
18 
Internal 
I2C_SCL1_LOW 
level 
LOGIC 
       
19 
Internal 
I2C_ACK 
does 
not 
respond 
LOGIC 
       
1C 
EEPROM initial setting is defective  LOGIC   
 
 
 
 
 
 
1D 
EEPROM 
write-down 
is 
defective 
LOGIC 
       
1E 
EEPROM user initial setting is 
defective 
LOGIC   
 
 
 
 
 
 
1F 
LOGIC 
EEPROM factory setting reading is 
defective 
LOGIC   
 
 
 
 
 
 
24 
Vex 
power 
voltage 
has 
decreased 
X-SUS 
LOGIC 
      
25 
Vex 
power 
voltage 
is 
excessive 
X-SUS 
       
26 
Vex 
power 
startup 
is 
faulty.  X-SUS 
LOGIC 
      
28 
Vx 
power 
voltage 
has 
dropped 
X-SUS 
LOGIC 
      
29 
Vx 
power 
voltage 
is 
excessive 
X-SUS 
       
2A 
Vx 
power 
startup 
is 
faulty.  X-SUS 
LOGIC 
      
39 
Vs power current is excessive 
(during operation) 
X-SUS 
Panel 
LOGIC 
     
3B 
X-SUS 
Vs power current is excessive 
(during startup) 
X-SUS 
Panel 
LOGIC 
     
44 
Vey power voltage has dropped 
Y-SUS  LOGIC   
 
 
 
 
 
45 
Vey 
power 
voltage 
is 
excessive 
Y-SUS 
       
46 
Vey 
power 
startup 
is 
faulty.  Y-SUS 
LOGIC 
      
59 
Vs power current is excessive 
(during operation) 
Y-SUS 
Panel 
LOGIC 
     
5B 
Vs power current is excessive 
(during startup) 
Y-SUS 
Panel 
LOGIC 
     
5D 
Y-SUS 
Vs power current is excessive 
(during operation) 
Y-SUS 
SDM 
Panel 
LOGIC 
    
61 
Vs 
power 
voltage 
is 
excessive 
PSU 
LOGIC 
      
62 
Vs power startup is faulty. 
X-SUS  Y-SUS  PSU 
LOGIC   
 
 
 
64 
Vex and Vpy power voltage has 
dropped 
LOGIC 
X-SUS 
Y-SUS 
     
65 
Vex and Vey power voltage is 
excessive 
X-SUS 
Y-SUS 
      
66 
Vex and Vey power startup is faulty.  LOGIC  X-SUS  Y-SUS   
 
 
 
 
68 
Vw 
power 
voltage 
has 
dropped 
Y-SUS 
X-SUS 
LOGIC 
     
69 
Vw 
power 
voltage 
is 
excessive 
X-SUS 
       
6A 
X-SUS 
Y-SUS 
 
Vw power startup is faulty. 
Y-SUS  X-SUS  LOGIC   
 
 
 
 
81 
Va 
power 
voltage 
is 
excessive 
PSU 
LOGIC 
      
82 
Va power startup is faulty. 
ADM1-8  PSU 
LOGIC  ABUS-L  ABUS-R   
 
 
99 
Va power current is excessive 
(during operation) 
ADM1-8 
ABUS-L 
ABUS-R 
PSU 
LOGIC 
   
9B 
ABUS 
Va power current is excessive 
(during startup) 
ADM1-8 
ABUS-L 
ABUS-R 
PSU 
LOGIC 
   
 
 
 
 
 
 
– 51 –
 
Suspected faulty board 
(In the order of higher probability of defect) 
ERR 
code 
Detect 
position 
(board) 
Contents 
(1) 
(2) 
(3) 
(4) 
(5) 
(6) 
(7) 
Remarks 
9D 
 
Va power current is excessive 
(during operation) 
ADM1-8 
ABUS-L 
ABUS-R 
PSU 
LOGIC 
  Excess 
current 
is 
detected in 
ACCC operation. 
A5 
ADM1 
ADM1 has abnormal heat 
generation. 
ADM1 
PSU 
LOGIC 
    
A9 
ADM2 
ADM2 has abnormal heat 
generation. 
ADM2 
PSU 
LOGIC 
    
AD 
ADM3 
ADM3 has abnormal heat 
generation. 
ADM3 
PSU 
LOGIC 
    
B1 
ADM4 
ADM4 has abnormal heat 
generation. 
ADM4 
PSU 
LOGIC 
    
B5 
ADM5 
ADM5 has abnormal heat 
generation. 
ADM5 
PSU 
LOGIC 
    
B9 
ADM6 
ADM6 has abnormal heat 
generation. 
ADM6 
PSU 
LOGIC 
    
BD 
ADM7 
ADM7 has abnormal heat 
generation. 
ADM7 
PSU 
LOGIC 
    
C5 
ADM8 
ADM8 has abnormal heat 
generation. 
ADM8 
PSU 
LOGIC 
    
It can possibly 
occur depending 
on screen 
display.  
E2 
LOGIC 
5V power startup is faulty. 
X-SUS  Y-SUS  PANEL  PSU 
ABUS-L  ABUS-R  LOGIC   
FC 
PSU 
Detection error of Vs and Va 
voltage. 
PSU 
LOGIC   
 
 
 
 
 
 
 
– 52 –
 
(1)
(3) 
(4) 
(2) 
(5) 
(7) 
(8) 
(9)
(11) 
(10)
 
(12) 
(13)
(14) 
(6) 
5 DISASSEMBLING AND REASSEMBLING 
Unless otherwise specified, use the torque screwdriver for screw tightening, following the   
tightening torques below. 
Screw size 
Tightening torque 
M 3 
69±0.049Nm (7±0.5kg·cm) 
M 4 
1.18±0.098Nm (12±1.0kg·cm) 
 
5.1 EXPLODED VIEW 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
42A1_5.1 DISASSEMBLE_LOGIC-L_1/2 
 
42A1_5.1DISASSEMBLE_LOGIC-L_1/2 
Page of 88
Display