Sony KDL-52V4100 / KDL-52W4100 / KDL-52WL140 Service Manual ▷ View online
29
KDL-52V4100/52W4100/52WL140
KDL-52V4100/52W4100/52WL140
KDL-52V4100 ONLY
SHEET CORE C (2-688-011-01)
QTY=11
LCD TAPE (2-688-062-01)
QTY=6
SLIDE CLAMP (2-650-770-01)
QTY=1 (UPPER VESA
SUPPORT)
SLIDE CLAMP (2-650-770-11)
QTY=12
CHO-FAB TAPE (2-888-494-01)
QTY=1
HIMELON TAPE (2-661-260-01)
QTY=1
LEGEND
INSTALLATION PROCEDURE FOR MDF-61 CONNECTOR
STEP1: ALIGN CONNECTOR
STEP2: INSTALL CONNECTOR
STEP3: PUSH DOWN ON BLACK
LOCK TAB TO SEAT CONNECTOR.
WHEN CONNECTOR IS SEATED IT
WILL “CLICK” INTO PLACE.
LOCK TAB TO SEAT CONNECTOR.
WHEN CONNECTOR IS SEATED IT
WILL “CLICK” INTO PLACE.
STEP4: PULL LOCK BLACK LOCK
TAB IN DIRECTION INDICATED ON
PWB TO LOCK CONNECTOR.
TAB IN DIRECTION INDICATED ON
PWB TO LOCK CONNECTOR.
“HRS” LOGO WILL BE VISIBLE WHEN
CONNECTOR IS PROPERLY LOCKED.
CONNECTOR IS PROPERLY LOCKED.
30
KDL-52V4100/52W4100/52WL140
KDL-52V4100/52W4100/52WL140
KDL-52V4100 ONLY
SHEET CORE C (2-688-011-01)
QTY=11
LCD TAPE (2-688-062-01)
QTY=6
SLIDE CLAMP (2-650-770-01)
QTY=1 (UPPER VESA
SUPPORT)
SLIDE CLAMP (2-650-770-11)
QTY=12
CHO-FAB TAPE (2-888-494-01)
QTY=1
HIMELON TAPE (2-661-260-01)
QTY=1
LEGEND
D4Z/D5 & G5 Board Wire Routing
1
8
7
9
10
2
4
ARROW COLOR CODE
D4Z to G5 (3P-RED UL)
G5 to D5 (3P-YELLOW UL)
D4Z to G5 (8P)
D4Z to D5 (10P)
G5 to D5 (3P-YELLOW UL)
D4Z to G5 (8P)
D4Z to D5 (10P)
11
NOTE:
Slide Clamp on end of Upper VESA
Support is -01 (larger size).
Color of clamp is Black.
Support is -01 (larger size).
Color of clamp is Black.
(White clamp is shown only as Reference).
31
KDL-52V4100/52W4100/52WL140
KDL-52V4100/52W4100/52WL140
KDL-52V4100 ONLY
SHEET CORE C (2-688-011-01)
QTY=11
LCD TAPE (2-688-062-01)
QTY=6
SLIDE CLAMP (2-650-770-01)
QTY=1 (UPPER VESA
SUPPORT)
SLIDE CLAMP (2-650-770-11)
QTY=12
CHO-FAB TAPE (2-888-494-01)
QTY=1
HIMELON TAPE (2-661-260-01)
QTY=1
LEGEND
Switch Unit Routing/Dressing
Apply Tape, LCD (3 Places) as shown.
4
5
6
4
Apply Slide Clamp (4 Places) as shown.
2
3
5
9
32
KDL-52V4100/52W4100/52WL140
KDL-52V4100/52W4100/52WL140
KDL-52V4100 ONLY
SHEET CORE C (2-688-011-01)
QTY=11
LCD TAPE (2-688-062-01)
QTY=6
SLIDE CLAMP (2-650-770-01)
QTY=1 (UPPER VESA
SUPPORT)
SLIDE CLAMP (2-650-770-11)
QTY=12
CHO-FAB TAPE (2-888-494-01)
QTY=1
HIMELON TAPE (2-661-260-01)
QTY=1
LEGEND
LVDS Cable Routing/Dress
(CRITICAL FOR EMI)
Apply 3x5mm Screw
to secure LVDS Cable to panel and
BU Board bracket.
MAKE SURE clip is centered between
Guides on panel BEFORE installing screw.
to secure LVDS Cable to panel and
BU Board bracket.
MAKE SURE clip is centered between
Guides on panel BEFORE installing screw.
CAUTION:
Securing grounding clip with 3x5mm
Screw is CRITICAL FOR EMI
Screw is CRITICAL FOR EMI
Route LVDS Cable in Slide Clamp.
Clamp is CRITICAL to Prevent LVDS from
Touching high-voltage area on D5 Board.
Clamp is CRITICAL to Prevent LVDS from
Touching high-voltage area on D5 Board.
11
1
8
9
10
2
1
3
Apply 3x8mm Screw
to secure LVDS Cable to panel and
BU Board bracket.
MAKE SURE clip is CENTERED
Between
Guides on Main Bracket BEFORE
installing
Screw.
to secure LVDS Cable to panel and
BU Board bracket.
MAKE SURE clip is CENTERED
Between
Guides on Main Bracket BEFORE
installing
Screw.
CAUTION:
Securing grounding clip with 3x5mm
Screw is CRITICAL FOR EMI
Screw is CRITICAL FOR EMI
See next page for details on
proper installation for cho-fab and
Himelon tapes.
proper installation for cho-fab and
Himelon tapes.
52V has x3 RED UL
Tape bands.
Tape bands.
Click on the first or last page to see other KDL-52V4100 / KDL-52W4100 / KDL-52WL140 service manuals if exist.