KDL-46NX810/55NX810/55NX811/60NX810  
8
After correcting the original service problem, perform the following safety checks before releasing the set to the customer:
1.  Check the area of your repair for unsoldered or poorly soldered connections. Check the entire board surface for solder splashes and 
SAFETY CHECK-OUT
bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” or touching 
high-wattage resistors.
3.  Check that all control knobs, shields, covers, ground straps, and mounting 
hardware have been replaced. Be absolutely certain that you have replaced 
all the insulators.
4.  Look for unauthorized replacement parts, particularly transistors, that 
were installed during a previous repair. Point them out to the customer and 
recommend their replacement.
5.  Look for parts which, though functioning, show obvious signs of deterioration. 
Point them out to the customer and recommend their replacement.
6.  Check the line cords for cracks and abrasion. Recommend the replacement 
of any such line cord to the customer.
7.   Check the antenna terminals, metal trim, “metallized” knobs, screws, and 
all other exposed metal parts for AC leakage. Check leakage as described 
below.
To Exposed Metal
Parts on Set
0.15 µF
Earth Ground
AC
Voltmeter
(0.75V)
Figure A. Using an AC voltmeter to check AC leakage.
KDL-46NX810/55NX810/55NX811/60NX810  
9
SAFETY CHECK-OUT
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and from all 
exposed metal parts to any exposed metal part having a return to chassis, must 
not exceed 0.5 mA(500 microamperes). Leakage current can be measured by 
any one of three methods.
1.  A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. 
Follow the manufacturers’ instructions to use these instructions.
2.  A battery-operated AC milliampmeter. The Data Precision 245 digital 
multimeter is suitable for this job.
3.  Measuring the voltage drop across a resistor by means of a VOM or 
battery-operated AC voltmeter. The “limit” indication is 0.75 V, so analog 
meters must have an accurate low voltage scale.
 
The Simpson’s 250 and Sanwa SH-63TRD are examples of passive VOMs 
that are suitable. Nearly all battery-operated digital multimeters that have a 
2 VAC range are suitable (see Figure A).
HOW TO FIND A GOOD EARTH GROUND
The cover-plate retaining screw on most AC outlet boxes is at earth ground.
Verify the AC outlet box retaining screw ground by connecting a 60-to 100-watt 
trouble-light (not a neon lamp) between the hot side of the receptacle and the 
retaining screw. Try both slots, if necessary, to locate the hot side on the line; 
the lamp should light at normal brilliance if the screw is at ground potential
(see Figure B).
Trouble Light
AC Outlet Box
Figure B. Checking for earth ground.
KDL-46NX810/55NX810/55NX811/60NX810  
10
SELF DIAGNOSIS FUNCTIONS
SELF DIAGNOSIS FUNCTION
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY LED will automatically begin to flash. The number 
of times the LED flashes translates to a probable source of the problem. A definition of the STANDBY LED flash indicators is listed in the 
instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the remote commander can be used to 
review the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
DIAGNOSTIC TEST INDICATORS
When an error occurs, the STANDBY LED will flash a set number of times to indicate the possible cause of the problem. If there is more than 
one error, the LED will identify the first of the problem areas. 
Result for all of the following diagnostic items are displayed on screen. 
If the screen displays a “0”, no error has occurred .
Diagnostic Item
Diagnostic Item
Description
Number of times 
Standby LED 
blinks
Possible Location
RGB_SEN
RGB Sensor ACK Error
NA
NA
MAIN_POWER
Main Power Over Voltage Protection
2
G9 Board (KDL-46NX810/55NX810/55NX811 Only) 
G10 Board (KDL-60NX810 Only)
G11 Board (KDL-60NX810 Only)
BUHT Board
DC_ALERT
DC Alert
DTT-WDT
DTT Error
AUD_PROT
Audio Error Detection
BALANCER
Panel Balancer Error
4
BUHT Board
TCON ERR
TCON Error
HFR ERR
HFR Error
P_ID_ERR
Panel ID NVM Error
BACKLITE
Backlight Error
6
BUHT Board
TEMP_ERR
Temperature Error
7
BUHT Board
FAN_ERR
Fan Error (Not Detected; Display Only)
NA
NA
3
5
BUHT Board
G9 Board (KDL-46NX810/55NX810/55NX811 Only)
G10 Board (KDL-60NX810 Only)
G11 Board (KDL-60NX810 Only)
LCD Panel
TCON Control MT Board
BUHT Board
Self Diagnosis
Supported model
KDL-46NX810/55NX810/55NX811/60NX810  
11
SELF DIAGNOSIS FUNCTIONS
STANDBY LED FLASH COUNT
 
Ambient Sensor/ 
(IR) Infrared Receiver
Picture Off /
Timer LED 
Standby LED
Power LED
 
0.5
0.5
3
0.5
0.5
3
Page of 43
Display