Sony KDL-32BX359 Service Manual ▷ View online
KDL-32BX359 29
SECTION 5 - UPDATES AND ADJUSTMENTS
COMPLETING SERVICE REQUIREMENTS WHEN
REPLACING THE LCD PANEL
The following must be performed after replacing the LCD Panel.
;
View the Status Information
;
Verify the Panel ID Code
;
Reset the Panel Operation Time
1. TV must be in Standby mode.
2. Press the following buttons on the
2. Press the following buttons on the
Remote Commander
within a second of each other:
DISPLAY
Channel 5
Volume +
POWER
Sound Adjustment
>>
Wide Band Tuning
>>
Range Scan…
>>
Self diagnosis history
>>
Status Information…
>>
LVDS Spectrum(%0)
<[
50
]>
Panel Selection
<[
T315XW04_V3
]>
SERIAL NUMBER EDIT
8000001
MODEL NAME EDIT
KDL-32BX359
[</>]Set [Menu] Exit
Service Mode
VIEWING THE STATUS INFORMATION
After replacing the LCD Panel you MUST UPDATE the SOFTWARE to the
latest version. Verify the latest software is installed before proceeding to the
service adjustments.
Whenever the LCD Panel is replaced, the software must be updated so that
Whenever the LCD Panel is replaced, the software must be updated so that
the new panel syncs with the Main Board. If a message displays indicating
the latest software is already installed, proceed to Resetting the LCD Panel
to Update the Software.
3. For instructions refer to the section
“Viewing the Status
Information” on page 24.
4. Do one of the following:
a. If the latest software is installed, proceed to
Verifying
the Panel ID Code.
b. If the latest software is not installed, update the software
and then proceed to
Verifying the Panel ID Code.
VERIFYING THE PANEL ID CODE
5. Press until
Panel Selection is selected.
Sound Adjustment
>>
Wide Band Tuning
>>
Range Scan…
>>
Self diagnosis history
>>
Status Information…
>>
LVDS Spectrum(%0)
<[
50
]>
Panel Selection
<[
T315XW04_V3
]>
SERIAL NUMBER EDIT
8000001
MODEL NAME EDIT
KDL-32BX359
[</>]Set [Menu] Exit
Service Mode
KDL-32BX359 30
SECTION 5 - UPDATES AND ADJUSTMENTS
6. Using the table below, verify the correct Panel Code for the
Panel ID.
Model Name
Panel Code
Panel Type
Panel ID
LTY[Z]320AN04
T315XW04_V3
SLCD
KDL-32BX359
7. Proceed to
Resetting the Panel Operation Time.
RESETTING PANEL OPERATION TIME
8. Press until
Self diagnosis history is selected.
9. On the
Self Check screen, identify the Panel Operation
Time location.
Back
<<
002
MAIN_ POWER
000
003
DC_ALERT1
000
003
AUDIO_PROT
000
004
BALANCER_ERR
000
005
TCON_ERR
000
005
PANEL_ID_NVM_ERR
000
006
BACKLIGHT_ERR
000
007
TEMP_ERR
000
00150
00075
00030
[Home] Exit
SELF CHECK
TOTAL OPERATION
TIME
PANEL OPERATION
TIME
BOOT COUNT
10. Press
7
0
.
11. Verify
Panel Operation Time has been changed to 00000.
Back
<<
002 MAIN_ POWER
000
003 DC_ALERT1
000
003 AUDIO_PROT
000
004 BALANCER_ERR
000
005 TCON_ERR
000
005 PANEL_ID_NVM_ERR
000
006 BACKLIGHT_ERR
000
007 TEMP_ERR
000
00150
00075
00000
[Home] Exit
SELF CHECK
12. To exit the
Self Check, press
HOME
.
KDL-32BX359 31
SECTION 5 - UPDATES AND ADJUSTMENTS
ACCESSING FACTORY ADJUSTMENT MODE
1. TV must be ON.
2. Press the following buttons on the
2. Press the following buttons on the
Remote Commander
within a second of each other:
MUTING
MUTING HOME
NOTE: The instructions to access
Factory Mode are NOT
THE SAME as the
Service Mode procedure.
Input Source
<[
TV
]>
White Balance
<[
Off
]>
Internal Pattern
<[
Off
]>
Color Temp
>>
Aging Mode
<[
Off
]>
ADC Calibration
>>
TVD ADC Calibration
>>
Auto Phase
<[
Off
]>
Factory Reset (default)
Off
Recall Data
<[
Off
]>
Data Backup
<[
Off
]>
Site Air Channels
<[
Off
]>
Site Cable Channels
<[
Off
]>
System FW
v2.003
Model Name
KDL-32BX359
Serial Number
8000001
Picture Quality
v1.0000
Audio Quality
AQ1.0000
Panel Info
T315XW04_V3
EDID Version
HDMI: 1.3 / VGA: 1.3
Factory Version
v2.003
[</>]Set [EXIT] Exit
Factory Mode
ADJUSTING THE COLOR TEMPERATURE
The default White Balance data values are set for optimal viewing. The
following instructions are for technicians who have been requested to
customize calibrations for their customers.
3. Using , scroll down to select
Color Temp.
Input Source
<[
TV
]>
White Balance
<[
Off
]>
Internal Pattern
<[
Off
]>
Color Temp
>>
Aging Mode
<[
Off
]>
ADC Calibration
>>
TVD ADC Calibration
>>
Auto Phase
<[
Off
]>
Factory Reset (default)
Off
Recall Data
<[
Off
]>
Data Backup
<[
Off
]>
Site Air Channels
<[
Off
]>
Site Cable Channels
<[
Off
]>
System FW
v2.003
Model Name
KDL-32BX359
Serial Number
8000001
Picture Quality
v1.0000
Audio Quality
AQ1.0000
Panel Info
T315XW04_V3
EDID Version
HDMI: 1.3 / VGA: 1.3
Factory Version
v2.003
[</>]Set [EXIT] Exit
Factory Mode
KDL-32BX359 32
SECTION 5 - UPDATES AND ADJUSTMENTS
4. Press
to access
Color Temp adjustments.
Back
<<
Color Temp
<[
Neutral
]>
R Gain
<[
538
]>
G Gain
<[
512
]>
B Gain
<[
452
]>
R Offset
<[
512
]>
G Offset
<[
512
]>
B Offset
<[
512
]>
Recall Data
<[
Off
]>
Data Backup
<[
Off
]>
[</>]Set [EXIT] Exit
Factory Mode
Color Temperature
5. Press or to select the
Color Temp type.
(Cool, Neutral, Warm1 or Warm2).
6. After the correct Color Temperature is selected, press to
select the temperature type that needs to be modified.
7. After the correct temperature type is selected, press to
increase the data value or press to decrease the data
value.
8. Complete the data value adjustments to the remaining
temperature items within the selected temperature type.
NOTE: Changes to the data value must be saved within the
temperature type selected before making changes to one of
the other temperature types.
9. To save the changes, press to select
Data Backup, then
press
.
Back
<<
Color Temp
<[
Neutral
]>
R Gain
<[
538
]>
G Gain
<[
512
]>
B Gain
<[
452
]>
R Offset
<[
512
]>
G Offset
<[
512
]>
B Offset
<[
512
]>
Recall Data
<[
Off
]>
Data Backup
<[
W/B
]>
[</>]Set [EXIT] Exit
Factory Mode
Color Temperature
10. Press to select the option
W/B and press
.
11. Do one of the following:
a. To make changes to one of the other temperature types,
repeat steps 5 through 10.
b. To exit
Factory Mode, press
HOME
.