KDL-32BX355/32BX356/40BX455/46BX455 5
SECTION 1 - FEATURES AND OVERVIEW
LCD PANEL ASSEMBLY
The LCD Panel Assembly includes the LCD Panel, TCON Board, and LED 
Backlight system.
The  LCD  Panel  contains  the  actual  liquid  crystals,  color  filters,  and 
polarizers. The  liquid  crystals  are  manipulated  by  the  applied  voltage  to 
pass a specific amount of light - from the backlight - depending on the level 
of voltage applied.
The TCON performs all the control, timing, charge, and discharge functions 
driving the operation of the LCD Panel.
A new LCD Panel Assembly from parts will include the following items.
 
LCD Panel
 
TCON Board
 
Inverter MT Board
TCON BOARD
The  TCON  Board  communicates  between  the  LCD  Panel  and  the 
microprocessor on the Main Board. 
NOTE:  The  TCON  Board  is  not  available  as  a  replacement  part  for  all 
models.  To  determine  if  the  TCON  Board  is  available  as  a  replacement 
part, refer to the LCD Panels Manual.
INVERTER MT BOARD
The inverter receives the unregulated 24V from the Power Supply Board 
and generates the required high voltage AC to power the backlight lamps. A 
control line to turn on the inverter (backlights on) is used in conjunction with 
a dimmer control to vary the light level of the CCFL lamps.
KDL-32BX355/32BX356/40BX455/46BX455 6
OVERVIEW
This chapter provides information regarding the Self Diagnosis feature in 
our TVs.
UPDATING THE SOFTWARE
The Self Diagnosis function is designed to provide information regarding 
the problem with the TV, however, there are several issues that may be 
resolved by updating the TV software to the latest version. Most symptoms 
that are correctable by software updates involve communications issues 
with other devices or minor glitches in the operation of a specific function. 
Below  is  a  list  of  some  of  the  symptoms  that  may  be  corrected  with  a 
software update:
 
Fluctuations in picture brightness
 
Intermittent picture freezing or noise
 
Problems with certain inputs (especially HDMI)
 
Intermittent or distorted audio
 
Erratic remote control operation
 
TV turns on and off by itself
 
Loss of color
 
Internet connectivity
 
Certain features not working correctly  
(photo or video file viewing)
SECTION 2 - TROUBLESHOOTING
Self Diagnosis
Supported model
SELF DIAGNOSIS FUNCTION
Critical voltages and circuit operations are monitored by the CPU on the 
Main Board. If an error is detected the Self Diagnosis function in the TV will 
force the TV to shut down by the CPU. The monitored circuit in which the 
fault occurred will automatically cause the CPU to blink the Standby LED 
in groups of repeating sequences. The number of times the Standby LED 
blinks indicates the possible cause of the problem.  
Not all of the available protect codes are used in every model. For example, 
models that don’t have the local dimming feature do not use the 4X blink 
error as this circuit is found in models that are backlit with fluorescent lamps. 
The information in this section provides guidance in locating the possible 
component causing the shutdown.
STANDBY LED BLINK COUNT
Standby LED
  
2 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
LED DISPLAY & BLINK COUNT
KDL-32BX355/32BX356/40BX455/46BX455 7
SECTION 2 - TROUBLESHOOTING
VIEWING THE SELF CHECK DIAGNOSIS HISTORY
When an error is detected, the Self Check screen records the date(s) and 
the number of times the error occurred. This is helpful in confirming past 
occurrences of an error, and for determining if an error is intermittent when 
the customer is not sure what is causing the television to shut down. If the 
screen displays a “0”, no error has occurred.   
1.  Take the TV out of deep Standby mode by pressing 
POWER
to 
turn on the TV.
2.  Press 
POWER
to turn the TV back off.
3.  Press the following buttons on the Remote Commander within a 
second of each other: 
DISPLAY
 
 Channel 
5
 
 Volume 
+
 
 
POWER
Sound Adjustment
>>
Wide Band Tuning
>>
Range Scan…
>>
Self diagnosis history
>>
Status Information…
>>
LVDS Spectrum(%0)
<[
20
]>
DPMS
<[
Off
]>
Low of HPD
<[
5
]>
TVD_MCDONE_CNT
<[
20
]>
Demo Special
>>
Bypass AVI Info Detect
<[
On
]>
Panel Selection
<[
LTY[Z]400HM09
]>
UART Selection
No Log
SERIAL NUMBER EDIT
5000027
MODEL NAME EDIT
KDL-40BX455
[</>]Set [Home] Exit
Service Mode
4.  To access the 
Self diagnosis history page, press   until Self 
diagnosis history is highlighted, and then press 
.
Back
<<
002 MAIN_ POWER
000
003 DC_ALERT1
000
003 AUDIO_PROT
000
004 BALANCER_ERR
000
005 TCON_ERR
000
005 PANEL_ID_NVM_ERR
000
006 BACKLIGHT_ERR
000
007 TEMP_ERR
000
00001
00036
00001
[Home] Exit
SELF CHECK
SAMPLE SELF CHECK DIAGNOSIS PAGE
2X Blink - Main Power Error
A loss of REG12V from the power supply triggers this protect event. The 
usual cause is a failure of the main switching supply. In some instances, 
excessive loading on the secondary supply lines can cause the switching 
regulator to stop, or fail again, if a replacement board is installed.
3X Blink- DC Regulator/Audio Error
The REG 5V and D3.3V source originating on the Main Board is monitored 
for  low-voltage  conditions  by  the  CPU. A  failure  causing  a  3X  shutdown 
requires replacing the Main Board.
4X Blink – Balancer Error
NOT USED IN THIS MODEL SERIES
5X Blink - TCON Error/Panel Error
The 5X blink protection mode indicates a communications error with the 
timing control circuits (TCON Board) has occurred. If the TCON Board is 
available for replacement, replace it, if not, replace the LCD Panel Assembly. 
In rare cases a loose or defective LVDS cable could also be the cause.
KDL-32BX355/32BX356/40BX455/46BX455 8
SECTION 2 - TROUBLESHOOTING
6X Blink - Backlight Converter System Failure
If the inverter circuits fails to generate high voltage or one or more of the 
backlight lamps fails to light, the television will shut down and display this 
diagnostics error. Observing for the presence of backlighting is crucial in 
determining which component is likely at fault.
If the backlights turn on before the 6X shutdown occurs, it is safe to assume 
that the inverter circuits are functioning and one of the lamps failed to ignite. 
Replacing the LCD Panel assembly is necessary. If the backlights never 
turn on before the 6X shutdown, the Inverter MT Board has failed. If this 
board is available for replacement, replace it, if not, replace the LCD Panel 
Assembly.
7X Blink - Temperature Failure
A digital thermometer IC located on the Main Board provides a temperature 
reading of the chassis and LCD panel. If the temperature exceeds a pre-
determined point the TV will shut down. If this problem occurs immediately 
at turn-on, the temperature sensing IC has failed and replacing the main 
board is required. If this occurs after the TV has been running for a while, 
check  for  ventilation  issues  that  could  cause  the  TV  to  run  hotter  than 
normal.
TRIAGE CHART
Use this general Triage Chart to determine what may possibly be causing the error before going out to the customers location. 
1.  Confirm the symptom from the customer.
5. Chart Color Code
2.  Select that symptom from the chart.
    RED DOT: (Primary) Most likely defective part  
3.  Bring the primary component listed for that symptom.
   BLUE Triangle: (Secondary) Possible defective part
Power
Audio
2X    3X    5X     6X    7X   
Dead set
No 
Video  
Whole 
Screen 
Distortion
Isolated 
Area 
Distortion   
No Audio   
Main Board
 
  
*
Power Supply
  
***
H Board
 
Inverter
▲*
LCD Panel
**
TCON
***Backlight Does NOT Turn ON before TV Shuts 
Video                 
Protection Modes
4.  Follow the associated flowcharts in the Training Manual to isolate the board.
Board 
* TV Immediate Shuts Off After Power ON & 7X
**Backlight Turns ON before TV Shuts Off
*NOTE: REFER TO LCD PANEL SERVICE 
MANUAL IN REFERENCE LIBRARY DATABASE 
FOR CORRECT REPLACEMENT PARTS BASED 
To  access  the  most  recent  version  of  the  Triage  documents  for  the  models  listed  in  this  manual,  login  into  the  Sony  Authorized  Servicer  Portal  at 
 
http://www.sony.com/asp
.
Page of 37
Display

Click on the first or last page to see other KDL-32BX355 / KDL-32BX356 / KDL-40BX455 / KDL-46BX455 service manuals if exist.