KDL-32BX355/32BX356/40BX455/46BX455 5
SECTION 1 - FEATURES AND OVERVIEW
LCD PANEL ASSEMBLY
The LCD Panel Assembly includes the LCD Panel, TCON Board, and LED
Backlight system.
The LCD Panel contains the actual liquid crystals, color filters, and
The LCD Panel contains the actual liquid crystals, color filters, and
polarizers. The liquid crystals are manipulated by the applied voltage to
pass a specific amount of light - from the backlight - depending on the level
of voltage applied.
The TCON performs all the control, timing, charge, and discharge functions
The TCON performs all the control, timing, charge, and discharge functions
driving the operation of the LCD Panel.
A new LCD Panel Assembly from parts will include the following items.
A new LCD Panel Assembly from parts will include the following items.
●
LCD Panel
●
TCON Board
●
Inverter MT Board
TCON BOARD
The TCON Board communicates between the LCD Panel and the
microprocessor on the Main Board.
NOTE: The TCON Board is not available as a replacement part for all
NOTE: The TCON Board is not available as a replacement part for all
models. To determine if the TCON Board is available as a replacement
part, refer to the LCD Panels Manual.
INVERTER MT BOARD
The inverter receives the unregulated 24V from the Power Supply Board
and generates the required high voltage AC to power the backlight lamps. A
control line to turn on the inverter (backlights on) is used in conjunction with
a dimmer control to vary the light level of the CCFL lamps.
KDL-32BX355/32BX356/40BX455/46BX455 6
OVERVIEW
This chapter provides information regarding the Self Diagnosis feature in
our TVs.
UPDATING THE SOFTWARE
The Self Diagnosis function is designed to provide information regarding
the problem with the TV, however, there are several issues that may be
resolved by updating the TV software to the latest version. Most symptoms
that are correctable by software updates involve communications issues
with other devices or minor glitches in the operation of a specific function.
Below is a list of some of the symptoms that may be corrected with a
software update:
●
Fluctuations in picture brightness
●
Intermittent picture freezing or noise
●
Problems with certain inputs (especially HDMI)
●
Intermittent or distorted audio
●
Erratic remote control operation
●
TV turns on and off by itself
●
Loss of color
●
Internet connectivity
●
Certain features not working correctly
(photo or video file viewing)
SECTION 2 - TROUBLESHOOTING
Self Diagnosis
Supported model
SELF DIAGNOSIS FUNCTION
Critical voltages and circuit operations are monitored by the CPU on the
Main Board. If an error is detected the Self Diagnosis function in the TV will
force the TV to shut down by the CPU. The monitored circuit in which the
fault occurred will automatically cause the CPU to blink the Standby LED
in groups of repeating sequences. The number of times the Standby LED
blinks indicates the possible cause of the problem.
Not all of the available protect codes are used in every model. For example,
Not all of the available protect codes are used in every model. For example,
models that don’t have the local dimming feature do not use the 4X blink
error as this circuit is found in models that are backlit with fluorescent lamps.
The information in this section provides guidance in locating the possible
component causing the shutdown.
STANDBY LED BLINK COUNT
Standby LED
2 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
LED DISPLAY & BLINK COUNT
KDL-32BX355/32BX356/40BX455/46BX455 7
SECTION 2 - TROUBLESHOOTING
VIEWING THE SELF CHECK DIAGNOSIS HISTORY
When an error is detected, the Self Check screen records the date(s) and
the number of times the error occurred. This is helpful in confirming past
occurrences of an error, and for determining if an error is intermittent when
the customer is not sure what is causing the television to shut down. If the
screen displays a “0”, no error has occurred.
1. Take the TV out of deep Standby mode by pressing
POWER
to
turn on the TV.
2. Press
POWER
to turn the TV back off.
3. Press the following buttons on the Remote Commander within a
second of each other:
DISPLAY
Channel
5
Volume
+
POWER
Sound Adjustment
>>
Wide Band Tuning
>>
Range Scan…
>>
Self diagnosis history
>>
Status Information…
>>
LVDS Spectrum(%0)
<[
20
]>
DPMS
<[
Off
]>
Low of HPD
<[
5
]>
TVD_MCDONE_CNT
<[
20
]>
Demo Special
>>
Bypass AVI Info Detect
<[
On
]>
Panel Selection
<[
LTY[Z]400HM09
]>
UART Selection
No Log
SERIAL NUMBER EDIT
5000027
MODEL NAME EDIT
KDL-40BX455
[</>]Set [Home] Exit
Service Mode
4. To access the
Self diagnosis history page, press until Self
diagnosis history is highlighted, and then press
.
Back
<<
002 MAIN_ POWER
000
003 DC_ALERT1
000
003 AUDIO_PROT
000
004 BALANCER_ERR
000
005 TCON_ERR
000
005 PANEL_ID_NVM_ERR
000
006 BACKLIGHT_ERR
000
007 TEMP_ERR
000
00001
00036
00001
[Home] Exit
SELF CHECK
SAMPLE SELF CHECK DIAGNOSIS PAGE
2X Blink - Main Power Error
A loss of REG12V from the power supply triggers this protect event. The
usual cause is a failure of the main switching supply. In some instances,
excessive loading on the secondary supply lines can cause the switching
regulator to stop, or fail again, if a replacement board is installed.
3X Blink- DC Regulator/Audio Error
The REG 5V and D3.3V source originating on the Main Board is monitored
for low-voltage conditions by the CPU. A failure causing a 3X shutdown
requires replacing the Main Board.
4X Blink – Balancer Error
NOT USED IN THIS MODEL SERIES
5X Blink - TCON Error/Panel Error
The 5X blink protection mode indicates a communications error with the
timing control circuits (TCON Board) has occurred. If the TCON Board is
available for replacement, replace it, if not, replace the LCD Panel Assembly.
In rare cases a loose or defective LVDS cable could also be the cause.
KDL-32BX355/32BX356/40BX455/46BX455 8
SECTION 2 - TROUBLESHOOTING
6X Blink - Backlight Converter System Failure
If the inverter circuits fails to generate high voltage or one or more of the
backlight lamps fails to light, the television will shut down and display this
diagnostics error. Observing for the presence of backlighting is crucial in
determining which component is likely at fault.
If the backlights turn on before the 6X shutdown occurs, it is safe to assume
If the backlights turn on before the 6X shutdown occurs, it is safe to assume
that the inverter circuits are functioning and one of the lamps failed to ignite.
Replacing the LCD Panel assembly is necessary. If the backlights never
turn on before the 6X shutdown, the Inverter MT Board has failed. If this
board is available for replacement, replace it, if not, replace the LCD Panel
Assembly.
7X Blink - Temperature Failure
A digital thermometer IC located on the Main Board provides a temperature
reading of the chassis and LCD panel. If the temperature exceeds a pre-
determined point the TV will shut down. If this problem occurs immediately
at turn-on, the temperature sensing IC has failed and replacing the main
board is required. If this occurs after the TV has been running for a while,
check for ventilation issues that could cause the TV to run hotter than
normal.
TRIAGE CHART
Use this general Triage Chart to determine what may possibly be causing the error before going out to the customers location.
1. Confirm the symptom from the customer.
5. Chart Color Code
2. Select that symptom from the chart.
RED DOT: (Primary) Most likely defective part
3. Bring the primary component listed for that symptom.
BLUE Triangle: (Secondary) Possible defective part
Power
Audio
2X 3X 5X 6X 7X
Dead set
No
Video
Whole
Screen
Distortion
Isolated
Area
Distortion
No Audio
Main Board
*
▲
▲
Power Supply
***
H Board
Inverter
▲*
LCD Panel
**
TCON
▲
▲
***Backlight Does NOT Turn ON before TV Shuts
Video
Protection Modes
4. Follow the associated flowcharts in the Training Manual to isolate the board.
Board
* TV Immediate Shuts Off After Power ON & 7X
**Backlight Turns ON before TV Shuts Off
*NOTE: REFER TO LCD PANEL SERVICE
MANUAL IN REFERENCE LIBRARY DATABASE
FOR CORRECT REPLACEMENT PARTS BASED
To access the most recent version of the Triage documents for the models listed in this manual, login into the Sony Authorized Servicer Portal at
http://www.sony.com/asp
.
Click on the first or last page to see other KDL-32BX355 / KDL-32BX356 / KDL-40BX455 / KDL-46BX455 service manuals if exist.