Sony KDF-46E2000 / KDF-46E2010 / KDF-50E2000 / KDF-50E2010 / KDF-55E2000 / KDF-55E2010 Service Manual ▷ View online
KDF-46E2000/46E2010/50E2000/50E2010/55E2000/55E2010
KDF-46E2000/46E2010/50E2000/50E2010/55E2000/55E2010
25
1-910-024-31 Connector Assy should be
dressed around Heat Sink and around Duct
Block Cover as shown above.
dressed around Heat Sink and around Duct
Block Cover as shown above.
BALLAST WIRE DRESSING (CONTINUED)
KDF-46E2000/46E2010/50E2000/50E2010/55E2000/55E2010
KDF-46E2000/46E2010/50E2000/50E2010/55E2000/55E2010
26
Before installing chassis
Dress CN3004[B],
CN8400[U], and CN3008[B]
to purse lock on bottom
block as shown.
Dress CN3004[B],
CN8400[U], and CN3008[B]
to purse lock on bottom
block as shown.
Loop Video 2 Connector
before installing into Purse
Lock as shown to avoid
Connector assy from
Touching [K] Board Heat
Sink.
before installing into Purse
Lock as shown to avoid
Connector assy from
Touching [K] Board Heat
Sink.
ONLY FOR 46" and 50"
models
models
Install Ferrite Clamp
154383011 to the following
Connector Assys
154383011 to the following
Connector Assys
1. Speaker Conn Assy
2. HA/HB Conn Assy
3. HC Conn Assy
2. HA/HB Conn Assy
3. HC Conn Assy
BOTTOM BLOCK WIRE DRESSING
KDF-46E2000/46E2010/50E2000/50E2010/55E2000/55E2010
KDF-46E2000/46E2010/50E2000/50E2010/55E2000/55E2010
27
Install Conn Assy
1-910-024-21 to "FAN1"
Optical Block Fan.
Dress 15P CN9000 [C]
LVDS Connector and Fan
Connector to Purse Lock
on [C] Shield
Route Optical Block Fan
to Wire Holder to avoid
being “Pinched” when [G]
Shield is installed
C BLOCK WIRE DRESSING
KDF-46E2000/46E2010/50E2000/50E2010/55E2000/55E2010
KDF-46E2000/46E2010/50E2000/50E2010/55E2000/55E2010
28
Dress [B] Block Fan and [K] Board Connector Assy to Purse
Lock on [B] Block as shown above.
Lock on [B] Block as shown above.
CHASSIS WIRE DRESSING
Dress the following
Connector Assys to
Purse Lock on Duct Block
Assy :
Connector Assys to
Purse Lock on Duct Block
Assy :
1. CN150 [T1]
2. X1 (Ballast)
3. X2 (Ballast)
2. X1 (Ballast)
3. X2 (Ballast)
Note:
Duct Block Fan is not
installed to Purse Lock
Duct Block Fan is not
installed to Purse Lock
Dress the following
Connector Assys to Wire
Holder on Bottom Block:
Connector Assys to Wire
Holder on Bottom Block:
1. 1-910-024-29
2. X1 (Ballast)
3. X2 (Ballast)
4. Duct Block Assy Fan
5. Optical Block Fan
2. X1 (Ballast)
3. X2 (Ballast)
4. Duct Block Assy Fan
5. Optical Block Fan
Route Lamp Fan
“inside” of 1-910-024-29
and Inside of X2 (Ballast
Power)
“inside” of 1-910-024-29
and Inside of X2 (Ballast
Power)
DUCT BLOCK ASSEMBLY WIRE DRESSING
Click on the first or last page to see other KDF-46E2000 / KDF-46E2010 / KDF-50E2000 / KDF-50E2010 / KDF-55E2000 / KDF-55E2010 service manuals if exist.