 22 
KD-30XS955/34XS955
Q BOX WIRE DRESSING
KD-30XS955/34XS955
 23 
KD-30XS955/34XS955
ECG WIRE DRESSING (XS & HS)
DY
Rotation
COIL
g (
)
Rev. 1
3/11/05
CRT BRKT
Earth Coating 
Ground Wire (ECG)
32”: 1-900-808-29
(Earth Coating Ground)
Integral Spring
2-Places
NOTE: Leads are 
dressed inside
Rotation Coil.
NOTE2: There are 
2 Leads (TOTAL 4 
Wires) to connect 
to CH-Board
Caution Points:
1. Make sure braided ECG wire loop does not
     twist, and stays flat on CRT surface.
2. Do not pull excessively on the tension spring
3. If the spring appears warped or stretched,
     replace entire parts. The braided ECG wire
     CANNOT sag on the CRT, and must remain
     under tension.
DY
Rotation
COIL
Rev. 1
3/11/05
CRT BRKT
NOTE: Leads are 
dressed inside
Rotation Coil.
NOTE2: There are 
2 Leads (TOTAL 4 
Wires) to connect 
to CX-Board
ECG - P/N
1-900-808-30 - 30 WCRT
1-900-808-31 - 34W CRT
SPRING (2 places)
 Integral part of
 the Ground wire
2-022-978-01
Wire Clip (2 Places)
30/34W ECG WIRE DRESSING (XS & HS)
KD-30XS955/34XS955
 24 
KD-30XS955/34XS955
30/34W XS DGC/LCC CAUTION POINT
DY
Rotation
COIL
Cable Tie
To CN504/505
    on A-Board
 LCC
 Coil
(Top)
 LCC
 Coil
(Top)
Rev. 1
3/11/05
Cable Tie
CN5805
[ DL ]
    LCC
    Coil
(Bottom)
    LCC
  Coil
(Bottom)
NOTE: MAKE SURE Cable Tie is 
positioned so it does NOT 
touch LCC COIL Wires! DO 
NOT apply Cable Tie over 
white/black LCC Tape!
NOTE: MAKE SURE wires are 
not too tight! Leave some 
Slack!
!
!
!
 Dress DGC 
 leads through
 Cable Ties!
KD-30XS955/34XS955
 25 
KD-30XS955/34XS955
DY
Rev. 1
3/11/05
Cable Tie
4-041-041-02
STEP1:
Make a loop in leads
and route loop BEHIND
The DGC Coil.
STEP 2:
Thread both connector
housings through the
loop in lead wires.
STEP 3:
Plug in connector
housings into the 
[A] Board using the
loop to take up slack.
30/34W DGC LEAD WIRE DRESSING (XS & HS)