3-6-2. HIGH LIGHT CONDITION
Input Video Signal:............................................................All White Signal
Picture level:..............................................Picture/Brightness Adjustment
Picture level:..............................................Picture/Brightness Adjustment
1. Short across C8002, C8021, C8052, C8012, and C8015.
2. Set ABL current to 2.76mA by adjusting picture and brightness
towards max condition.
3. Adjust HV to obtain 35.7 ± 0.15kV by precision RV1 jig.
4 Remove short from C8002 and confi rm that hold down activates.
5. Short C8002 again and confi rm that HV recovers.
6. Re-adjust HV to obtain 32.2 ± 0.2 kV by precision VR1 jig.
7. Remove shorts from C8002, C8021, and C8052.
8. Confi rm that hold down does not activate.
9. Remove short from C8012 and C8015.
10. Remove VR1 jig from D board
2. Set ABL current to 2.76mA by adjusting picture and brightness
towards max condition.
3. Adjust HV to obtain 35.7 ± 0.15kV by precision RV1 jig.
4 Remove short from C8002 and confi rm that hold down activates.
5. Short C8002 again and confi rm that HV recovers.
6. Re-adjust HV to obtain 32.2 ± 0.2 kV by precision VR1 jig.
7. Remove shorts from C8002, C8021, and C8052.
8. Confi rm that hold down does not activate.
9. Remove short from C8012 and C8015.
10. Remove VR1 jig from D board
3-7. IK PROTECTOR CHECK
Input Video Signal:............................................................All White Signal
Picture level:...............................................Picture/Brightness Adjustment
Picture level:...............................................Picture/Brightness Adjustment
1. Short across C8015.
2. Set ABL current to 2.76mA by adjusting picture and brightness
towards max condition.
3. Confi rm that AC Relay shuts off.
4. Remove short from C8015 and Short across C8012.
5. Turn the set off and on to reset AC relay latch.
6. Confi rm the voltage at CN5009 pin 8 (H_prot) = 3.6 ± 0.5V.
7. Remove short from C8012.
2. Set ABL current to 2.76mA by adjusting picture and brightness
towards max condition.
3. Confi rm that AC Relay shuts off.
4. Remove short from C8015 and Short across C8012.
5. Turn the set off and on to reset AC relay latch.
6. Confi rm the voltage at CN5009 pin 8 (H_prot) = 3.6 ± 0.5V.
7. Remove short from C8012.
3-8. HOLD DOWN CHECK
1. Using an external DC power supply, apply 5.3 + 0.5 Vdc
between Pin 2 of CN507 (jig connector) and ground (Pin 8) on
between Pin 2 of CN507 (jig connector) and ground (Pin 8) on
A board.
2. Confi rm that hold down activates.
3. Remove the external DC power supply.
3. Remove the external DC power supply.
3-9. RESTORATION
1. Re-solder CN5001 pin 1 and CN5009 pin 8 to restore A -D
connections.
(Or as applicable, restore A –D connector by carefully pressing the
tab back into the slot and snapping the connector shut. Be sure the
tab is fl ush and level with the other tabs on the connector.)
(Or as applicable, restore A –D connector by carefully pressing the
tab back into the slot and snapping the connector shut. Be sure the
tab is fl ush and level with the other tabs on the connector.)
2. Remove jumper wire from M board connection CN2304 pin 1 to
CN509 pin 1.
3. Remove current meter from ABL pin and restore ABL pin connection.
4. Replace all D board screws and restore user menu settings to reset
4. Replace all D board screws and restore user menu settings to reset
condition.
39
KD-30XS955/34XS955
KD-30XS955/34XS955
3-10. HV SERVICE FLOWCHART
Confirm:
- Ik Protector
Refer to P. 38
YES
Is the spare part on
P. 40 changed?
Is D Board
NO
Start
Which category part
on P. 40 changed?
NO
YES
Finished with HV service
Confirm:
- HV
- HV Protector
- Ik Protector
Refer to P. 37/38
Confirm:
- HV Protector
Refer to P. 37/38
Confirm:
- B+
Refer to P. 37
Confirm:
- HV
Refer to P. 37/38
Confirm:
- B+
- Hold Down
Refer to P. 37
Category A
Category B
Category C
Category D
Category E
40
KD-30XS955/34XS955
KD-30XS955/34XS955
Ref. #
Category
T8001
A
R8015
C
R8017
C
R8019
D
R8035
E
R8036
E
R8037
E
R8038
E
R8039
E
R8040
E
R8043
E
R8078
D
R8165
D
IC8005
C
IC8104
D
R8012
C
R8014
C
R8016
D
R8021
C
R8027
E
R8029
E
R8030
E
R8031
E
R8046
D
R8052
D
R8059
C
R8060
C
R8066
C
R8072
D
R8079
D
R8082
E
R6590
B
D8022
D
PH8003
C
Q8007
E
Q8008
E
IC8001
D
IC8002
C
IC8004
C
IC6503
B
HV SERVICE FLOWCHART TABLE
41
KD-30XS955/34XS955
KD-30XS955/34XS955
SECTION 4: CIRCUIT ADJUSTMENTS
4-1. REMOTE ADJUSTMENT BUTTONS AND
INDICATORS
RM-Y199
3
Increase
Data Value
Data Value
POWER
(Service Mode)
(Enter into
memory)
memory)
MUTING
6
Decrease
Data Value
5
Display
Previous Category
VOLUME (+)
(Service Mode)
Display
Next Item
Next Item
1
Display
Next Category
2
Display
Previous Item
4
(Initialize)
8
DISPLAY
(Service Mode)
(Remove from
Memory)
Memory)
0
ENTER
(Enter into Memory)
ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER
Use the Remote Commander (RM-Y199) to perform the circuit adjustments in this section.
Test Equipment Required:
1. Pattern generator 2. Frequency counter 3. Digital multimeter 4. Audio oscillator
4-2. ACCESSING SERVICE ADJUSTMENT
MODE
1. Standby mode (Power off).
2. Press the following buttons on the remote commander within a
2. Press the following buttons on the remote commander within a
second of each other:
DISPLAY
Channel
5
Sound Volume +
POWER
The screen displays the fi rst service data category item.
VERSION
Category
Item
Data Value
0
0
VER
FULL
SERVICE
3. On the Remote Commander, press 2 or 5 to select the category.
4. Press 1 or 4 to select the item.
5. Press 3 or 6 to change the data.
6. Press MUTING then ENTER to write into memory.
4. Press 1 or 4 to select the item.
5. Press 3 or 6 to change the data.
6. Press MUTING then ENTER to write into memory.
VERSION
Category
Item
Text changes to
“WRITE” and
changes from
green to red
Data Value
0
0
VER
FULL
WRITE
4-2.1. SERVICE ADJUSTMENT MODE
MEMORY
1. Access Service Adjustment Mode.
2. Press 8 on the Remote Commander to initialize.
2. Press 8 on the Remote Commander to initialize.
VERSION
Category
Item
Text changes to
“RESET” and
changes from
green to red
Data Value
0
0
VER
FULL
RESET
3. DO NOT turn off set until “SERVICE” appears.
Click on the first or last page to see other KD-30XS955 (serv.man2) service manuals if exist.