DOWNLOAD Sony RM-PJ2 / VPL-ES1 Service Manual ↓ Size: 4.49 MB | Pages: 75 in PDF or view online for FREE

Model
RM-PJ2 VPL-ES1
Pages
75
Size
4.49 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector
File
rm-pj2-vpl-es1.pdf
Date

Sony RM-PJ2 / VPL-ES1 Service Manual ▷ View online

1-12
VPL-ES1
CN905
CN809
CN811
CN806
CN802
2 Three screws 
     (
+BTP 3 x 10)
4 Fan holder
7 D.C. fan (Sirocco) 
6 Two dowels
3 Remove the fan holder
     in the direction of the arrow.
C board
1 Remove the 
     fuse connector assembly
5 Remove the 
     
harneses
Dowel 
D.C. fan (Sirocco) 
1-3-16. D.C. Fan (Sirocco)
1-13
VPL-ES1
4 Optics block assembly
• Remove the optics block assembly.
  (Refer to 1-3-8.)
5 Three screws 
     (
+BTP 3 x 10)
7 Dowel
8 Remove the adjuster block assembly
     in the direction of the arrow.
6 Dowel
9 Adjuster block assembly
1 C board
• Remove the C board. 
  (Refer to 1-3-3.)
3 Lamp house
• Remove the lamp house.
  (Refer to 1-3-7.)
2 Fan holder
• Remove the fan holder. 
  (Refer to 1-3-5.)
1-3-17. Adjuster Block Assembly
. To remove the adjuster block assembly, remove the related parts beforehand.
1-14
VPL-ES1
1-4. Warning on Power Connection
n
. When a signal other than the preset signals shown above is input, the picture may not appear properly.
. Memory No. 22 shows the interlace signal.
Warning on power connection
Use a proper power cord for your local power supply.
The United States,
Continental Europe
UK, Ireland,
Japan
Canada
Australia,
New Zealand
Plug type
VM0233
290B
YP-12A
COX-07
-(1)
YP332
Connector type
VM0089
386A
YC-13B
COX-02
VM0310B
YC-13
Cord type
SJT
SJT
H05VV-F
H05VV-F
N13237/CO-228
VCTF
Rated Voltage & Current
10A/125V
10A/125V
10A/250V
10A/250V
10A/250V
7A/125V
Safety approval
UL/CSA
UL/CSA
VDE
VDE
VDE
DENAN
Cord length (max.)
4.5m
     –
(1) Use an appropriate rating plug which is applied to local regulations.
2-1
VPL-ES1
Section 2
Electrical Adjustments
2-1. Preparation
2-1-1. Required Equipment
. NTSC, PAL, SECAM component signal generator
Sony Tektronix TG2000 
+ AVG1 (option module) +
AWVG1 (option module) or equivalent
. VG (programmable video signal generator)
VG854 or equivalent
. Illuminance meter
n
Allow the warm-up time of 5 minutes after the power is on
before starting the following adjustments.
2-1-2. Opt Unit Adjustment
1.
Let the VPL-ES1 show the ALL WHITE screen.
2.
Adjust the B-channel illumination adjustment mirror
so that the yellow frame must not appear in any of top,
bottom, right and left of the screen.
3.
Tighten the adjustment plate fixing screw using a
torque screwdriver. (Torque 0.19 
±0.03 Nm)
4.
Adjust the G-channel illumination adjustment mirror
so that the magenta frame must not appear in any of
top, bottom, right and left of the screen.
5.
Tighten the adjustment plate fixing screw using a
torque screwdriver. (Torque 0.19 
±0.03 Nm)
6.
Adjust the R-channel illumination adjustment mirror
so that the cyan frame must not appear in any of top,
bottom, right and left of the screen.
7.
Tighten the adjustment plate fixing screw using a
torque screwdriver. (Torque 0.19 
±0.03 Nm)
8.
Confirm that the illumination range error is within the
allowable range of product specification.
9.
Install the VPL-ES1 in the cabinet. Confirm that the
illumination range error is within the allowable range
of product specification after the VPL-ES1 is installed
in the cabinet.
When installing the optical unit in this model, alignment of
the gear tooth position is required. Perform the following
steps.
Procedure
1.
Rotate the lens focus and zoom in the fully clockwise
positions. Lock the lens gear in the direction shown in
Fig. 1.
Fig. 1
2.
Align the marking position of the lens zoom gear with
the protrusion of the lens gear approximately by visual
observation as shown below.
Fig. 2 (inside view)
Lens projection
Lens gear
Gear alignment portion
Lens gear
Lens gear
Zoom
Focus
Lens gear
Lens
Engage the gears.
Page of 75
Display

Click on the first or last page to see other RM-PJ2 / VPL-ES1 service manuals if exist.