DOWNLOAD Sony DPP-SV88 Service Manual ↓ Size: 4.2 MB | Pages: 40 in PDF or view online for FREE

Model
DPP-SV88
Pages
40
Size
4.2 MB
Type
PDF
Document
Service Manual
Brand
Device
Service Manual / Other / V1 E1 REV1
File
dpp-sv88.pdf
Date

Sony DPP-SV88 Service Manual ▷ View online

2-11
DPP-SV88 V1
E capstan roller
Pinch roller
Roller bearing
Roller 
bearing
B
A
A
C
13. Rotate the two roller bearings in the direction indicated
by the arrow A, then remove them.
14. Move the E capstan roller in the direction indicated by
the arrow B, then remove it in the direction indicated
by the arrow C.
15. Attach the E capstan roller in the reverse order of steps
1 to 14.
3-1
DPP-SV88 V1
Section 3
Service Mode
Fig.3-1
Operation panel
Activation
1.
Connect the power cord to DPP-SV88 (hereafter referred to as this unit) and connect the video cable,
connected to a monitor, to the VIDEO OUT terminal of this unit.
2.
Turn on the power while pressing the  Menu  and  Save  keys simultaneously.
3.
Release the keys when the service mode screen (shown in Fig. 3-1) appears on the monitor screen.
Input select
Menu
Folder recall
Effect
Creative print
Save all
Direction
Print
Save
INPUT SELECT
MENU
EFFECT
CREATIVE PRINT
Picture
Print Q’ty
Enter
Cancel
SAVE ALL FOLDER RECALL CANCEL
SAVE
PRINT
PICTURE
ENTER
PRINT QTY
3-2
DPP-SV88 V1
Fig.3-2
Fig.3-3
3-1. Density Adjustment during Thermal Head Replacement
Before replacing the thermal head, print a test pattern (gray pattern) as the reference of density using an
old head or normal unit.
n
For the test pattern print of an old head, use the thermal head that is not damaged as a whole due to black
and white stripes.
Procedure
1.
Set the ribbon and paper.
n
Use the set paper below.
Small-size photo paper SVM-30SS
2.
Enter the service mode, move the 
\ mark to “Mechanic Test” using  Direction  keys, and press the
Enter  key. (Fig. 3-2)
3.
Press the  Print  key when the screen (shown in Fig. 3-3) is displayed on the monitor screen.  This
unit initiates the print of a density confirmation pattern (gray).
3-3
DPP-SV88 V1
Fig.3-4
4.
Press the  Cancel  key when the printing is completed.
5.
When the screen shown in Fig. 3-2 is displayed on the monitor screen, turn off the power and
disconnect the power cord from this unit.
6.
Replace the thermal head.
m
. When replacing the thermal head, confirm the resistance value of old and new heads and find the
difference in the resistance value.
. The resistance value is described beside the head.
7.
After the thermal head is replaced, connect the power cord and enter the service mode again.  At that
time, confirm that a 
\ mark is located in “Print Calibrate” on the monitor screen and press the  Enter
key. (Fig. 3-4)
8.
Confirm the display in parentheses in the lower-left position when the screen (shown in Fig. 3-5) is
displayed on the monitor screen. (An example of the screen is R2-4.)
The print voltage after replacement is determined by the difference between the display in
parentheses and the head resistance value in step 6.
n
The voltage applied to the head is changed by the head resistance value.  The change in a voltage is
adjusted in two levels.
Page of 40