2-6. 
Note on the IM Assy (FIX-2000) and the Front Chassis
When replacing the IM Assy (FIX-2000) and the Front chassis, select the shim to be used newly referring to the following
procedures.
Note
Perform the selection of shim for each three positions.
IM Omega Unit (2000)
1.
Remove the IM omega unit (2000) and the three shims.
IM Omega Unit (2000)
Shim
2.
Measure the dimensions [A] of the removed shim.
PXW-FS5/PXW-FS5K
2-7
3.
Measure the distance [B] between the surface of the screw hole where the shims are set and the surface of the E-
Mount.
SSM height adjustment
measurement JIG
J-6082-689-A
[A] + [B]
[A]
[B]
4.
After replaced the IM Assy and Front chassis, measure the dimensions [B'] same as procedure 3.
5.
Calculate the dimension [A'] of new shim by using the formula below, and select the shim.
[A']=[A]+[B]-[B']
Tip
• [A]: shim dimension before replacement
• [A']: shim dimension to use newly
• [B]: the dimension between the surface of the screw hole before replacement and the surface of the E-Mount
• [B']: the dimension between the surface of the screw hole after replacement and the surface of the E-Mount
6.
Assemble the IM omega unit (2000), using the selected shims.
7.
Perform the test shooting and confirm that nor blur is observed in the peripheral area of shot.
About checking method, refer to the 
“2-7. Photographic Resolving Power (tilt-shift) Check/Adjustment”
.
PXW-FS5/PXW-FS5K
2-8
2-7. 
Photographic Resolving Power (tilt-shift) Check/Adjustment
Equipment and Tools
• 50 mm F1.4 α lens (SAL50F14)
• Mount adaptor (LA-EA1 or LA-EA3)
• 4K monitor or 4K BRAVIA
• Resolving power check chart
Note
Prepare the resolving power check chart as following procedure.
1.
Download the “Focus-Chart_16_9.pdf”.
2.
Print “Focus-Chart_16_9.pdf” in letter size (8.5 inch X 11.0 inch).
228 mm
129 mm
Preparations
1.
Set the unit as shown below.
• Shooting mood: QFHD
• Bit rate: 100 mbps
• Iris: Release
PXW-FS5/PXW-FS5K
2-9
2.
Set up the unit as follows.
• Attach the Mount adaptor and 50 mm F1.4 α lens (SAL50F14) to the unit.
• Install this unit so that the shooting distance between the mount surface of the unit and the resolving power
check chart becomes 600 mm.
600mm (between the mount surface of the 
unit and the Resolving power check chart)
• Adjust the unit position so that the resolving power check chart becomes fully image frame as shown in the
figure below.
Photographic resolving power (tilt-shift) check
1.
Set the unit as the following and focus.
2.
Shoot movie.
3.
Check that the shot movie is obtained the criteria shown in the figure below.
PXW-FS5/PXW-FS5K
2-10