2-3. 
Precaution on Replacing the VC-1039 Board
The board for repair is not recorded the information unique to a model. Therefore the following data are needed to write.
Note
The [LOAD AND WRITE] function in “ADJUSTMENT DATA BACKUP” on the DATA tab in the Adjust Manual
overwrites all data of the unit. Therefore execute the [LOAD AND WRITE] before performing the following operation.
2-3-1. 
Destination Data
The destination data stored in the repairing board is different from the destination setting stored in the board before
replacement in some cases.
When the board has been replaced with a repairing board, be sure to set the destination.
Method of the destination data write:
Start the Adjust Manual in the Adjust Station and execute the “Destination data write” on the ADJUST tab.
2-3-2. 
Restore Data
Before replacing the board with a repairing board, be sure to extract the data from the former one.
Method of the data extracting:
Start the Adjust Manual in the Adjust Station and execute the “RESTORE DATA” on the DATA tab.
2-3-3. 
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have
been written.
These IDs have not been written in a new repairing board. Therefore, after the board has been replaced, be sure to write
these IDs to a new repairing board.
Method of the ID writing:
Start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB SERIAL No. INPUT” on
the ADJUST tab.
2-3-4. 
Update of MAC Address
When a board that contains Wi-Fi has been replaced or when replacing a board that contains the main IC (CPU), the
IC’s unique number (MAC address) must be reloaded.
Procedure of the MAC address update:
Note
Perform the below operations after all work has been done.
1.
Start the Adjust Manual in the Adjust Station and execute the “Wireless LAN Setting (MAC Address)” on
the ADJUST tab.
2.
Operate the unit to initialize of SSID/PW.
PXW-FS5/PXW-FS5K
2-3
Applicable parts:
• VC-1039 BOARD, COMPLETE (SERVICE)
• WF-1004 BOARD, COMPLETE
Note
After the replacement and repair, the MAC address is changed, and thus the re-setting for connection devices is required.
Accordingly, download the Flyer of WLAN Reset (Flyer of WLAN Reset_9834752[][].pdf) and print out it, and attach
it to the set when returning the set to customer.
PXW-FS5/PXW-FS5K
2-4
2-4. 
Notes for Replacing the EVF Display Device (LCD902) 
WB adjustment values of each EVF display device (LCD902) are stored on the VC-1039 board.
Therefore, when the EVF display device (LCD902) or the VC-1039 board has been replaced, write WB adjustment
values.
The label which is put on repairing EVF display device:
White balance value
Brightness value
223 460
Procedure of the WB adjustment values writing when the EVF display device (LCD902) is
replaced:
1.
Check and write down the adjustment values printed on the repairing EVF display device (LCD902) label.
2.
After the EVF display device (LCD902) has been replaced, execute “EVF Data Input” on the ADJUST tab
by using the Adjust Manual in the Adjust Station to write the adjustment values.
Procedure of the WB adjustment values writing when replacing VC-1039 board (in case
adjustment values can be read):
1.
Start the Adjust Manual in the Adjust Station before replacing the VC-1039 board, and execute [DATA READ
AND SAVE] in the "ADJUSTMENT DATA BACKUP" on the DATA tab to extract WB adjustment values.
2.
Start the Adjust Manual in the Adjust Station after the VC-1039 board has been replaced, and execute [DATA
LOAD AND WRITE] in the "ADJUSTMENT DATA BACKUP" on the DATA tab to write the extracted WB
adjustment values.
When replacing VC-1039 board (in case adjustment values cannot be read):
1.
Read the QR code printed in EVF display device (LCD902) using with “QR_Code_Reader_Ver1.0_x64”.
2.
Make sure the adjustment value from the read value as shown below, and memorize it.
1
1
195
2
9
3
5
4
8
5
8
6
1
172
7
7
8
0
9
2
10
1
11
A
Example: In case the read value is “1958817021A”
Brightness value
White balance value
3.
Start the Adjust Manual in the Adjust Station and execute the “EVF Data Input” on the ADJUST tab.
PXW-FS5/PXW-FS5K
2-5
2-5. 
Checking the Wi-Fi Function
After this unit has been disassembled and reassembled, check the Wi-Fi function.
Required equipment:
Windows PC or smartphone with Wi-Fi interface
Procedure:
1.
Turn on the power of the unit and enable the Wi-Fi function.
(Upon completion of the preparation for Wi-Fi connection, the password for Wi-Fi connection is displayed.)
2.
Confirm on the PC or the smartphone that the unit is detected as a connectable wireless network.