1-2. 
Method of Coping with Shift Lens Error 
1-2-1. 
E:62:02 Abnormality of IC for Steadyshot
Identify the cause of the problem (lens or GY-1009 board), and replace the faulty lens or the GY-1009 board.
1-2-2. 
E:62:20 Abnormality of Thermistor
Check the connection between the lens block and GY-1009 board.
Identify the cause of the problem (lens or GY-1009 board), and replace the faulty lens or the GY-1009 board.
PXW-FS5/PXW-FS5K
1-5
Section 2
Service Note
2-1. 
Operation Notes
2-1-1. 
Flexible Board
• Make sure that the conductive side of a flexible board does not have any stain or foreign materials.
• Do not touch the conductive side of flexible boards with bare hands.
• Plug in a flexible board straight, fully into the connector until it reaches the end inside.
Flexible
Board
Flexible
Board
Connector
Connector
Reference line
Flexible
Board
Connector
Connector
Flexible
Board
Reference line
Connector
Connector
Flexible
Board
Flexible
Board
Reference line
OK 
(The flexible board was plugged in 
straight and completely)
(The flexible board was plugged in 
crooked.)
NG 
NG 
(The flexible board was not plugged in 
completely.)
• When opening the connector's holder in direction A, do not open it with excessive force.
Holder
Connector
Flexible Board
A
A
• When closing the connector's holder, press it evenly while pushing a flexible board in direction B.
Holder
Insulation side
Connector
Flexible Board
B
• Make sure that the flat cable and flexible board are not cracked or bent at the contact end.
Cut and remove the part of gilt
which comes off at the point.
(Be careful or some
pieces of gilt may be left inside)
• Do not apply excessive force to the gilded flexible board.
2-1-2. 
Fine-Wire Coaxial Cable
• The proper way to disconnect a connector is to grab the connector instead of the wires. If you pull on the wires,
they might be broken.
• The proper way to connect a connector is to grab the connector instead of the wires. If you push on the wires, they
might be broken.
PXW-FS5/PXW-FS5K
2-1
2-2. 
Power Supply during Repairs 
2-2-1. 
AC power adaptor
Use the AC power adaptor.
PXW-FS5/PXW-FS5K