Sony MHS-FS3 / MHS-FS3K (serv.man2) Service Manual ▷ View online

MHS-FS3/FS3K_ADJ
5-5
(2) Near Focus Adjustment
1)  Print out the Near Focus chart from the manual in A4 size, and attach 
it to the wall.
2)  Be sure to set 12 + 1cm distance between the Near Focus chart and 
the tip of camera lens.
3)  Check that the center of Near Focus chart meets the center of LCD 
display.
Color temperature = 5000 ± 300K
Luminance: LV9 to 11
Be sure not to turn off the power during adjusting.
The adjustment finished normally.
Far_L OK OOO
Right Focus ADJ...
Near_L OK OOO
Fig. 5-2-7
Pls Adjust Right lens
The adjustment is complete.
Far_L OK OOO
Near_R OK OOO
Far_R OK OOO
Fig. 5-2-8
Pls Key MENU Enter...
Near_L OK OOO
The adjustment is complete.
The adjustment is finished abnormally.
Far_L OK OOO
Near_L NG XXX
Fig. 5-2-9
Pls Readjust Near_L...
Malfunction of Left Near Focus 
Adjustment.
Far_L OK OOO
Near_R NG XXX
Far_R OK OOO
Fig. 5-2-10
Pls Readjust Near_R...
Near_L OK OOO
Malfunction of Right Near Fo-
cus Adjustment.
Adjustment order
Screen display
Fig. 5-2-6
Equipment required: Near Focus chart
Near Focus chart
12 + 1cm
Camera
In case of the “Left Near Focus Adjustment” is
finished abnormally, the following indication
appears on the screen. (Fig. 5-2-9)
In this case, confirm the adjusting environment
and readjust.
In case of the “Right Near Focus Adjustment” is
finished abnormally, the following indication
appears on the screen. (Fig. 5-2-10)
In this case, confirm the adjusting environment
and readjust.
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
Check that “Far Focus Adjustment” (Page 5-4) is finished normally.
Place the camera in front of the Near Focus chart. (Fig. 5-2-6)
Press the
button (Key S1), then AF Adjustment (Near Focus Adjustment) starts.
In case of the “Left Near Focus Adjustment” is
finished normally, the adjustment completion
indication appears on the screen. (Fig, 5-2-7)
The adjustment will proceed to “Right Far Focus
Adjustment” (Page 5-4), do not execute
the
button (Key S1)
operation.
In case of the “Right Near Focus Adjustment” is
finished normally, the adjustment completion
indication appears on the screen. (Fig, 5-2-8)
5-2-2. AWB Adjustment
 
(1) AWB Adjustment
The White Balance and Bad Pixel Adjustment is as follows.
Small pattern box (PTB-1450) setting: 
Color temperature = 3150 ± 50K
Luminance: LV12.3 ± 0.2
The adjustment finished normally.
Fig. 5-2-12
WB OK OOO
Bad Pixel OK OOO
The adjustment is complete.
When the adjustment is finished 
normally, perform the “Lens 
Shading Adjustment” 
(Page 5-6).
The adjustment is finished abnormally.
L_WB NG XXX
Fig. 5-2-13
Malfunction of White Balance 
Adjustment
R_WB NG XXX
Fig. 5-2-14
Malfunction of White Balance 
Adjustment
WB OK OOO
Bad Pixel NG XXX
Fig. 5-2-15
Malfunction of Bad Pixel Ad-
justment
Adjustment order
Screen display
Fig. 5-2-11
Equipment required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
(All black)
Small pattern box
(PTB-1450)
3mm or less
Black cloth
Camera
Check that the camera is on the adjustment mode.
∗ For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the Small pattern box (PTB-1450) and cover them (all black) with black cloth. (Fig. 5-2-11)
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
the adjustment completion indication appears
on the screen. (Fig. 5-2-12) The adjustment will
proceed to “Lens Shading Adjustment” (Page 5-6),
do not execute the
button (Key S1)
operation.
In case of the adjustment is finished normally,
the following indication appears on the screen.
(Fig. 5-2-13 to 5-2-15)
In case of the adjustment is finished abnormally,
In this case, confirm the adjusting environment
and readjust.
Press the
button (Key S1), then AWB Adjustment starts.
Press the Multi-selector button “ b (Key Left)”.
MHS-FS3/FS3K_ADJ
5-6
5-2-3. 3D Adjustment
1)  To use the FS3-chart, print out 4 pages of FS3-chart in A3 size (by 
100%) from the manual, and make them in one page by matching 
the number of each fitting mark“
”.
 
the width : 772mm
  the height: 546mm
2)  Attach the FS3-chart set above on the wall.
Note : • Make sure that the distance is 85 ± 1 cm between the FS3-chart and 
the tip of camera lens.
 
• Set the camera to make it face to the FS3-chart.
 
• Set the FS3-chart while confirming the LCD to make the green pane 
“ ”
 at the center of the chart match the center of the LCD.
Color temperature = 4000 to 7000K
Luminance: LV11 to 13
The adjustment finished normally.
Fig. 5-2-21
3D OK OOO
The adjustment is complete.
The adjustment is finished abnormally.
Fail to Get Pos
Fig. 5-2-22
Malfunction of 3D Adjustment
3D NG XXX
Fig. 5-2-23
Malfunction of 3D Adjustment
NG:XY Over Offset
Fig. 5-2-24
Malfunction of 3D Adjustment
Check that the camera is on the adjustment mode.
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
∗ For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the FS3-chart. (Fig. 5-2-20)
the adjustment completion indication appears
on the screen. (Fig. 5-2-21)
Turn off the power to quit the adjustment mode.
In case of the adjustment is finished normally,
the following indication appears on the screen.
(Fig. 5-2-22 and 5-2-24)
In case of the adjustment is finished abnormally,
In this case, confirm the adjusting environment
and readjust.
Press the
button (Key S1), then 3D Adjustment starts.
Press the
button (Key S1).
Fig. 5-2-20
Equipment required: FS3-chart
FS3-chart
85 1cm
Camera
+-
(2) Lens Shading Adjustment
When the indication (Fig. 5-2-16) appears on the LCD display, set the 
adjustment jig according to procedures shown below. (Fig. 5-2-17)
1)  Set the Light balance filter to make it cover the surfaces of both 
camera lenses.
2)  place the camera in front of the small pattern box.
 
The Lens Shading Adjustment order is as follows.
The adjustment finished normally.
Fig. 5-2-18
Lens shading OK OOO
The adjustment is complete.
The adjustment is finished abnormally.
Lens shading NG XXX
Fig. 5-2-19
Malfunction of Lens Shading 
Adjustment
Fig. 5-2-17
Equipment required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
(All black)
Light balance filter
Light balance filter
Small pattern box
(PTB-1450)
3mm or less
Black cloth
Camera
Setting of Small pattern box (PTB-1450) with the Light balance 
filter: 
Color temperature = 5200 ± 300K
Luminance: LV9.4 ± 0.2
Fig. 5-2-16
Lens Shading ADJ...
VX.XXADJ
20XX-XX-XX
Please Key S1 Start...
Attach the Light balance filter to the tip of the camera lens.
Check that the “AWB Adjustment” (Page 5-5) is finished normally.
Place the camera in front of the Small pattern box (PTB-1450) and cover them (all black) with black cloth. (Fig. 5-2-17)
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
the adjustment completion indication appears
on the screen. (Fig. 5-2-18)
Turn off the power to quit the adjustment mode.
In case of the adjustment is finished normally,
the following indication appears on the screen.
(Fig. 5-2-19)
In case of the adjustment is finished abnormally,
In this case, confirm the adjusting environment
and readjust.
Press the
button (Key S1), then Lens Shading Adjustment starts.
Adjustment order
Screen display
Adjustment order
Screen display
MHS-FS3/FS3K_ADJ
5-7
5-2-4. Bright Pixel Adjustment
The Bright Pixel Adjustment is as follows.
Note:
 
•  Perform this adjustment after that performed in “5-2-2. AWB Adjustment”.
(Page 5-5)
•  The Bright Pixel Adjustment proceeds automatically.
•  It may take more than 40 minutes to perform the Bright Pixel Adjustment 
due to the status of the camera (including more than 1 minutes for warming-
up, and more than 20 minutes for main adjustment). 
The adjustment finished normally.
Fig. 5-2-30
OK Burnin defect pixel
The adjustment is complete.
The adjustment is finished abnormally.
Still Adjusting ...
BadCount: xxxxx
Bright Pixel NG XXX
over
Fig. 5-2-31
Malfunction of Bright Pixel 
Adjustment
NG Burnin dfect Pixel
Fig. 5-2-32
Malfunction of Burnin dfect 
Pixel Adjustment
Fig. 5-2-26
Run: 00XX TimeCnt: 0XXX
Connect the USB charging adaptor.
Fig. 5-2-28
XXXX XX Adj...
Bright Thd: XXXX
Over
XXXX XX Adj...
Bright Thd: XXXX
Below
The automatic adjustment is complete.
Fig. 5-2-29
Run: 00XX TimeCnt: 0360
The warming up is complete.
Fig. 5-2-27
Still Adjusting...
The adjustment starts automatically.
Fig. 5-2-25
Equipments required: Cover camera lens
(All black)
Camera
Black cloth
Check that the camera is on the adjustment mode.
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
∗ For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Cover camera lens (all black). (Fig. 5-2-25)
Press the Multi-selector button “ V (Key Down)”.
the adjustment completion indication appears
on the screen. (Fig. 5-2-30)
The adjustments required when replacing Lens Unit
for MHS-FS3 are completed.
Remove the adjustment FW according to
procedures shown below.
1) Turn off the power of the camera.
2) Disconnect the USB extension cable from the USB
charge adaptor.
3) Connect the USB extension cable disconnected in
step 2) to PC.
4) Turn on the power of the camera.
5) Remove the SDV5095C.bin saved in the
“BLOGGIE_SW” root directory.
In case of the adjustment is finished normally,
the following indication appears on the screen.
(Fig. 5-2-31 and 5-2-32)
In case of the adjustment is finished abnormally,
In case of the Bright Pixel Adjustment is failed,
after turning off the power of the camera,
restart the adjustment from the “5-2-2 AWB
Adjustment” (Page 5-5).
Press the
button (Key S1), then Bright Pixel Adjustment starts.
Connect the USB charging adaptor after the screen turned to that shown in Fig. 5-2-26.
The camera will automatically keep operating abnormally for more than 1 minutes during warming up.
Perform the adjustment from beginning if the screen got frozen.
The screen will light out for a few seconds, then turn to that shown in Fig. 5-2-27 and start the adjustment automatically.
After the automatic adjustment finished, the screen will turn to that shown in Fig. 5-2-28.
In case of “Over”, warming up will restart automatically.
In case of “Below”, it will proceed to the next step automatically.
The camera will automatically keep operating abnormally for more than 20 minutes
after the screen turned to that shown in Fig. 5-2-29.
Perform the adjustment from beginning if the screen got frozen.
Adjustment order
Screen display
MHS-FS3/FS3K_ADJ
5-8
5-2-6. Set Language Destination
Language Destination Setting:
Save “lang.txt” in the root directory of the removable disk named “BLOGGIE”.
The content of “lang.txt” is as follows: 
Language Destination (for example: 5_UC3) (enter key)
Product ID (10bit) (enter key) (refer to “5-3 PRODUCT ID LIST” (Page 5-9))
S/N (8bit) (enter key)
The following is an example of 5_UC3 Language Destination Setting for MHS-FS3 Black camera.
5_UC3
0002095730
08432345
Especially Attention:
1)  The enter key must be the end symbol of each row.
2)  For the Product ID, refer to “5-3 PRODUCT ID LIST” (Page 5-9), and the Product ID must be 10bit.
 
If the Product ID is less than 10 bit, add 0 before the Product ID.
3)  The S/N must be 8 bit. It refer to the serial number of shipment.
The adjustment is finished abnormally.
Set LangDest NG!
Pls check Lang.txt
Fig. 5-2-38
or if MassProduct!
Malfunction of Set Language 
Destination
In case of the Set Language 
Destination is failed, reset the 
language destination.
The adjustment finished normally.
Set LangDest OK!
S/N:
0002095730
Fig. 5-2-37
Color: Black
ProductNum:
08432345
Dest: 5_UC3
The adjustment is complete.
Note:  The screen shown above is an example.
5-2-5. 360 Adjustment (MHS-FS3K Only)
The 360 Adjustment is as follows.
Press and hold both sides of the 360 video lens (1), then attach it to the 
camera in the direction (2).
Note1:   Attach the hooks of the 360 video lens to the attaching parts of the 
camera, as shown in Fig. 5-2-33.
Note2:  When repairing the parts related to the lens module of MHS-FS3K.
• Ask the customer to send the 360 Video Lens with the unit.
• Perform 360 Adjustment with the 360 Video Lens sent from the 
customer.
The adjustment finished normally.
Save callb value OK
Fig. 5-2-35
Save status OK
Ct X:xxxx Yxxx offset Xxx Yx
The adjustment is complete.
The adjustment is finished abnormally.
out of the range
Fig. 5-2-36
Malfunction of 360 Adjustment. 
If the white pane departs from 
the 360 video lens too much, 
which cause it is beyond the 
compensation scope of FW. 
Fig. 5-2-33
Equipments required: 360 video lens
360 video lens
1
2
1
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
Set the camera to the adjustment mode.
∗ For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Press the
button (Key S1), then Language Destination Setting starts.
Press the MOVIE/ENTER button (Key OK).
the adjustment completion indication appears
on the screen in a moment. (Fig. 5-2-37)
The adjustment will proceed to “5-2-7 Check all above
adjustment result” (Page 5-9), do not execute any
key operation.
In case of the adjustment is finished normally,
the following indication appears on the screen.
(Fig. 5-2-38)
and readjust.
In case of the adjustment is finished abnormally,
In this case, confirm the adjusting environment
Set the camera to the adjustment mode.
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Mount the 360 video lens to the camera. (Fig. 5-2-33)
Press the MOVIE/ENTER button (Key OK).
In case of the adjustment is finished normally, the
adjustment completion indication appears on the screen.
(Fig. 5-2-35)
The adjustments required when replacing Lens Unit for
MHS-FS3K are completed.
Remove the adjustment FW according to procedures
shown below.
1) Turn off the power of the camera.
2) Disconnect the USB extension cable from the USB
charge adaptor.
3) Connect the USB extension cable disconnected in
step 2) to PC.
4) Turn on the power of the camera.
5) Remove the SDV5095C.bin saved in the
“BLOGGIE_SW” root directory.
the following indication appears on the screen.
(Fig. 5-2-36)
In case of the adjustment is finished abnormally,
In this case, confirm the adjusting environment
and readjust.
Press the Multi-selector button “ B (Key Right)”, then press the
button (Key S1).
Move the white pane to match it with the center of the ring-shaped image
by pressing the Multi-selector buttons “v (Key Up)”, “V (Key Down)”,
“b (Key Left)” and “B (Key Right)”.
White pane
Ring-shaped image
Fig. 5-2-34
Adjustment order
Screen display
Adjustment order
Screen display
Page of 14
Display

Click on the first or last page to see other MHS-FS3 / MHS-FS3K (serv.man2) service manuals if exist.