DOWNLOAD Sony MHS-FS3 / MHS-FS3K (serv.man2) Service Manual ↓ Size: 3.21 MB | Pages: 14 in PDF or view online for FREE

Model
MHS-FS3 MHS-FS3K (serv.man2)
Pages
14
Size
3.21 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / ADJUSTMENT MANUAL
File
mhs-fs3-mhs-fs3k-sm2.pdf
Date

Sony MHS-FS3 / MHS-FS3K (serv.man2) Service Manual ▷ View online

MHS-FS3/FS3K_ADJ
Sony Corporation
Revision History
SECTION 5
ADJUSTMENT
ADJ
983457051.pdf
2011D29-1
© 2011.04
Published by Sony Techno Create Corporation
Ver. 1.0  2011.04
9-834-570-51
MHS-FS3/FS3K
Link
•  PREPARATIONS
•  Adjustment Items When Replacing Lens  
Unit (includes CMOS) and Main Board
•  List of Service Tools and Equipment
•  Keys and Functions
•  Connecting the Equipment
•  Setting the Adjustment Mode
•  CAMERA SECTION ADJUSTMENTS
•  AF Adjustment
•  AWB Adjustment
•  3D Adjustment
•  Bright Pixel Adjustment
•  360 Adjustment (MHS-FS3K Only)
•  Set Language Destination
•  Check all above adjustment result  
(When Replacing Main Board only)
•  Remove adjustment FW (When Replacing  
Main Board only)
•  PRODUCT ID LIST
Ver.
Date
History
Contents
S.M. Rev.
issued
1.0
2011.04
Official Release
Link (Japanese)
•  準備
•  レンズユニット(CMOSを含む),メイン基板
交換後の調整項目
•  使用機器/治具リスト
•  各部の名称
•  使用機器の接続
•  調整モードへの移行
•  カメラ部調整
•  AF調整
•  AWB調整
•  3D調整
•  Bright Pixel調整
•  360調整(MHS-FS3Kのみ)
•  言語仕向け設定
•  全調整結果の確認
(メイン基板交換時のみ)
•  調整用ファームウェアの削除
(メイン基板交換時のみ)
•  プロダクトID表
MHS-FS3/FS3K_ADJ
5-2
5. ADJUSTMENT
5-1.  PREPARATIONS
5-1-2. List of Service Tools and Equipment
5-1-3. Keys and Functions
Following are keys and functions used in adjustment. (Fig. 5-1-2)
5-1-4. Connecting the Equipment
Connect the USB Extension cable to USB charging adaptor and perform the adjustment during charging the built-in battery. (Fig. 5-1-3)
Charge lamp may turn off during adjustment, but it does not affect the charging.
5-1-1. Adjustment Items When Replacing Lens Unit (includes CMOS) and Main Board
When replacing these parts, adjust the items indicated by “ z ” in the following table.
Adjustment
Replaced parts
Lens Unit
(includes CMOS)
Main Board
AF Adjustment
z
z
AWB Adjustment
z
z
3D Adjustment
z
z
Bright Pixel Adjustment
z
z
360 Adjustment
(MHS-FS3K only)
z
z
Set Language Destination
z
J-1
J-3
J-5
J-4
J-6
J-2
Fig. 5-1-1
J-7
J-8
J-9
Small pattern box
PTB-1450
J-6082-557-A
Mini flange back jig
J-6082-719-A
or
Flange back
adjustment jig
J-6082-563-A
Camera table
J-6082-384-A
AC-U50A series
or
AC-U501AD
USB charging adaptor
Near Focus chart
(Note1)
FS3-chart
(Note2)
USB extension cable
(A plug to A socket)
(Commercially available)
Ball head
(Tiltable angle: 90° max.)
(Commercially available)
360 video lens
(Accessory)
(MHS-FS3K only)
J-10
Light balance filter
LB140
J-6080-058-B
or
Filter for color
temperature correction
(C14)
J-6080-058-A
Fig. 5-1-3
To USB connector
Ball head
(Commercially available)
USB extension cable
(A plug to A socket)
(Commercially available)
USB charging adaptor
(AC-U50A series or AC-U501AD)
To USB jack
Camera table
(J-6082-384-A)
Only for [5-2-4. Bright Pixel Adjustment]
Menu button
ON/OFF (Power) button
Charge lamp
button (Key S1)
Fig. 5-1-2
MOVIE/ENTER button
Multi-selector buttons
MOVIE/ENTER
button
(Key OK)
button (Key Right)
button (Key Up)
button (Key Left)
button (Key Down)
Note1:  Print out the Near Focus chart from the manual in A4 size.
Note2:  To use the FS3-chart, print out 4 pages of FS3-chart in A3 size (by 100%) from the manual, and make them in one page by matching the number of each 
fitting mark
.
MHS-FS3/FS3K_ADJ
5-3
Pressing the MENU button, the adjustment is completed and the initial screen for the adjustments appears.
To continue the adjustment, perform the operations mentioned from the next page.
Pressing the MENU button after the “Lens Shading Adjustment”, “3D Adjustment” and the “Bright Pixel Adjustment” finished normally, the screen 
will return to the normal mode. Be sure to turn off the power of the camera once.
When all adjustments are completed, press the ON/OFF (Power) button to finish the adjustment operations.
5-1-5. Setting the Adjustment Mode
1)  Download the firmware file “FS3_[][][]ADJ.zip”, “FS3K_[][][]ADJ.zip” from the ESI homepage.
 
Uncompress the  “FS3_[][][]ADJ.zip”, “FS3K_[][][]ADJ.zip” then confirm that it includes the following item.
•  SDV5095C.bin
 
Note:
  Since the file name “SDV5095C.bin” is used on the above two models, pay attention to the applicable model from mistake.
2)  Connect the camera to PC with USB extension cable, and turn on the power of the camera.
3)  Save the uncompressed file “SDV5095C.bin” in the root directory of the removable disk named “BLOGGIE_SW”.
 
Note:
  Saving it in other directories causes a malfunction of program.
4)  With the camera turned off.
5)  Disconnect the USB extension cable from PC.
6)  Connect the equipment to be used by referring to “5-1-4 Connecting the Equipment” (Page 5-2).
7)  Press the MOVIE/ENTER button (Key OK) for about five seconds and release when the LCD display turns on.
8)  After a few seconds, the LCD display will turn on and then show the adjustment mode screen. (Fig. 5-1-4)
Key S1: 3D Adjust
Key Down: Bright Pix Adjust
Key Right: 360 Adjust
Key OK: Set Lang and Check Result
Key Left: AWB Adjust
Key Up: AF Adjust
Fig. 5-1-4
MHS-FS3/FS3K_ADJ
5-4
5-2. CAMERA SECTION ADJUSTMENTS
5-2-1. AF Adjustment
 
(1) Far Focus Adjustment
Note:
 
When using the Flange back adjustment jig, take care of the following points:
•  For the illumination, use a light source such as an incandescent lamp or inverter type fluorescent light free from flickering.
•  Do not make an adjustment in the environment where fluorescent lamp flickering occurs even if the illuminance can be ensured with the room illumination only.
•  Use an incandescent lamp or inverter type fluorescent light at a place free from the influence of room illumination.
1)  Print out the Near Focus chart from the manual in A4 size, and attach 
it to the Flange back adjustment jig.
2)  Install the Flange back adjustment jig so that the distance between 
it and the front of lens of camera is 3cm or less.
Note:  Take care not to hit the lens of camera against the lens of Flange 
back adjustment jig.
3)  Make the height of Flange back adjustment jig and the camera equal.
4)  Check that the center of Near Focus chart meets the center of shot 
image screen. 
Color temperature = 5000 ± 300K
Luminance: LV9 to 11
Be sure not to turn off the power during adjusting.
The adjustment finished normally.
Fig. 5-2-2
Pls change to Near Focus
Far_L OK OOO
The adjustment is complete.
Far_L OK OOO
Far_L OK OOO
Near_L OK OOO
Fig. 5-2-3
Pls change to Near Focus
The adjustment is complete.
The adjustment is finished abnormally.
Far_L NG XXX
Fig. 5-2-4
Pls Readjust Far_L...
Malfunction of Left Far Focus 
Adjustment
Far_L OK OOO
Far_R NG XXX
Near_L OK OOO
Fig. 5-2-5
Pls Readjust Far_R...
Malfunction of Right Far Focus 
Adjustment
Adjustment order
Screen display
Fig. 5-2-1
Equipment required: Flange back adjustment jig
Flange back adjustment jig
Near Focus chart
3cm or less
Camera
Near Focus chart
Check that the camera is on the adjustment mode.
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
∗ For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the Flange back adjustment jig. (Fig. 5-2-1)
Press the Multi-selector button “ v (Key Up)”.
Press the
button (Key S1), then AF Adjustment (Far Focus Adjustment) starts.
In case of the “Left Far Focus Adjustment” is
finished normally, the adjustment completion
indication appears on the screen. (Fig, 5-2-2)
The adjustment will proceed to “Left Near Focus
Adjustment” (Page 5-5), do not execute
the
button (Key S1)
operation.
In case of the “Right Far Focus Adjustment” is
finished normally, the adjustment completion
indication appears on the screen. (Fig. 5-2-3)
The adjustment will proceed to “Right Near Focus
Adjustment” (Page 5-5), do not execute
the
button (Key S1)
operation.
In case of the “Left Far Focus Adjustment” is
finished abnormally, the following indication
appears on the screen. (Fig. 5-2-4)
In this case, confirm the adjusting environment
and readjust.
In case of the “Right Far Focus Adjustment” is
finished abnormally, the following indication
appears on the screen. (Fig. 5-2-5)
In this case, confirm the adjusting environment
and readjust.
Page of 14
Display

Sony MHS-FS3 / MHS-FS3K (serv.man2) Service Manual ▷ Download

  • DOWNLOAD Sony MHS-FS3 / MHS-FS3K (serv.man2) Service Manual ↓ Size: 3.21 MB | Pages: 14 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony MHS-FS3 / MHS-FS3K (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Sony MHS-FS3 / MHS-FS3K (serv.man2) Movie. Information contained in Sony MHS-FS3 / MHS-FS3K (serv.man2) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.