DOWNLOAD Sony HDR-HC5 / HDR-HC5E / HDR-HC7 / HDR-HC7E (serv.man4) Service Manual ↓ Size: 1.18 MB | Pages: 126 in PDF or view online for FREE

Model
HDR-HC5 HDR-HC5E HDR-HC7 HDR-HC7E (serv.man4)
Pages
126
Size
1.18 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-hc5-hdr-hc5e-hdr-hc7-hdr-hc7e-sm4.pdf
Date

Sony HDR-HC5 / HDR-HC5E / HDR-HC7 / HDR-HC7E (serv.man4) Service Manual ▷ View online

6-27
HDR-HC5/HC5E/HC7/HC7E_ADJ
2.
Modification of A, B, D, 1A, 1B Page Data
If the A, B, D, 1A, 1B page data has been initialized, change the
data of the “Fixed data-2” address shown in the following table by
manual input.
Processing before Modification A, B, D, 1A, 1B page data:
Order Page Address Data Procedure
1
0
01
01
2
0
10
00
3
7
01
38
4
7
02
FF
5
7
04
02
6
7
00
01
Press PAUSE (Write) button.
7
7
02
Check the data changes to
“01”.
Modifying Method:
1) If modification of data on pages A, B, D, set data: 00 to page:
0, address: 10, and then select pages A, B, D.
2) If modification of data on pages 1A, 1B, set data: 01 to page:
0, address: 10, and then select pages A, B.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1:
If copy the data built in the different model, the
camcorder may not operate.
4) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
5) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification A, B, D, 1A, 1B
page data:
Order
Page
Address
Data Procedure
1
0
10
00
2
7
01
38
3
7
02
FF
4
7
04
01
5
7
00
01
Press PAUSE (Write) button.
6
7
02
Check the data changes to
“01”.
7
2
00
29
8
2
01
29
Press PAUSE (Write) button.
Note 2:
If following symptoms occur after completing of the
“Modification A, B, D, 1A, 1B page data”, check that
the data of the “Fixed data-2” address of A, B, D, 1A, 1B
page are same as those of same model of same destina-
tion.
1) The power is shut off so that unit cannot operate.
3.
A Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10
00
00
Test mode
11 to 17
Fixed data-1 (Initialized data)
18
Fixed data-2
19 to 2E
Fixed data-1 (Initialized data)
2F
Fixed data-2
30
Fixed data-1 (Initialized data)
31
Fixed data-2
32 to 7B
Fixed data-1 (Initialized data)
7C
7D
7E
Fixed data-2
7F
80 to 8F
Fixed data-1 (Initialized data)
90
E8
EA
91
0E
0D
92
DE
DD
Touch panel adj.
93
19
17
94 to FF
Fixed data-1 (Initialized data)
4.
B Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to D0
Fixed data-1 (Initialized data)
D1
00
00
D2
00
00
D3
00
00
D4
00
00
D5
00
00
USB Serial number data setting
D6
00
00
D7
00
00
D8
00
00
D9
00
00
DA to FF
Fixed data-1 (Initialized data)
6-28
HDR-HC5/HC5E/HC7/HC7E_ADJ
5.
D Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 15
Fixed data-1 (Initialized data)
16
Fixed data-2
17 to 27
Fixed data-1 (Initialized data)
28
29
2A
2B
2C
Fixed data-2
2D
2E
2F
30 to 35
Fixed data-1 (Initialized data)
36
37
38
39
Fixed data-2
3A
3B
3C to 57
Fixed data-1 (Initialized data)
58
Fixed data-2
59 to FF
Fixed data-1 (Initialized data)
6.
1A Page table
Note 1:
If reading/writing data on pages 1A, set data: 01 to page:
0, address: 10, and then select pages: A. By this data set-
ting, the pages 1A can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 6F
Fixed data-1 (Initialized data)
70
71
72
Fixed data-2
73
74 to 77
Fixed data-1 (Initialized data)
78
79
Fixed data-2
7A
7B
Fixed data-1 (Initialized data)
7C
7D
7E
7F
Fixed data-2
80
81
82 to FF
Fixed data-1 (Initialized data)
7.
1B Page table
Note 1:
If reading/writing data on pages 1B, set data: 01 to page:
0, address: 10, and then select pages: B. By this data set-
ting, the pages 1B can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
6-29
HDR-HC5/HC5E/HC7/HC7E_ADJ
1-3-2.
Initialization of 8, 9, C, 13, 18, 1C, 1D Page Data
1.
Initializing of 8, 9, C, 13, 18, 1C, 1D Page Data
Note 1:
If “Initialization of Pages 8, 9, C, 13, 18, 1C, 1D” is ex-
ecuted, all data on pages 8, 9, C, 13, 18, 1C, 1D are ini-
tialized. (Only an individual page cannot be initialized)
Note 2:
If the 8, 9, C, 13, 18, 1C, 1D page data has been initial-
ized, the following adjustments need to be performed
again.
1) Modification of 8, 9, C, 13, 18, 1C, 1D page data
2) Electronic viewfinder system adjustments (if all ar-
eas were initialized)
3) LCD system adjustments (if all areas were initial-
ized)
4) Node unique ID No. input (if all areas were initial-
ized)
5) Servo and RF system adjustments (if all areas were
initialized)
6) Video system adjustments (if all areas were initial-
ized)
Adjustment Page
8
Adjustment Address
00 to FF
Adjustment Page
9
Adjustment Address
00 to FF
Adjustment Page
C
Adjustment Address
10 to FF
Adjustment Page
13
Adjustment Address
00 to FF
Adjustment Page
18
Adjustment Address
00 to FF
Adjustment Page
1C
Adjustment Address
00 to FF
Adjustment Page
1D
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
Set the following data, and
press PAUSE (Write) button.
(Note 3)
3
3
81
00: Initializing all areas
01: Initializing other than
adjustment address
4
3
80
0C
Press PAUSE (Write) button.
Check the data changes to
5
3
80
“1C”.
6
Perform “Modification of 8,
9, C, 13, 18, 1C, 1D Page
Data”
Note 3:
If other than adjustment address was initialized, the ad-
justed data is not initialized.
2.
Modification of 8, 9, C, 13, 18, 1C, 1D Page Data
If the 8, 9, C, 13, 18, 1C, 1D page data has been initialized, change
the data of the “Fixed data-2” address shown in the following table
by manual input.
Processing before Modification 8, 9, C, 13, 18, 1C, 1D
page data:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
71
01
Press PAUSE (Write) button.
Modifying Method:
1) If modification of data on pages 8, 9, C, set data: 00 to page: 0,
address: 10, and then select pages 8, 9, C.
2) If modification of data on pages 13, 18, 1C, 1D,  set data: 01
to page: 0, address: 10, and then select pages 3, 8, C, D.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
4) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
5) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification 8, 9, C, 13, 18, 1C, 1D
page data:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
70
10
Press PAUSE (Write) button.
4
3
70
Check the data changes to
“11”.
5
2
00
29
6
2
01
29
Press PAUSE (Write) button.
6-30
HDR-HC5/HC5E/HC7/HC7E_ADJ
3.
8 Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to AE
Fixed data-1 (Initialized data)
AF
B0
Fixed data-2
B1
Fixed data-1 (Initialized data)
B2
B3
Fixed data-2
B4
Fixed data-1 (Initialized data)
B5
B6
B7
Fixed data-2
B8
B9 to C2
Fixed data-1 (Initialized data)
C3
C4
C5
C6
C7
Fixed data-2
C8
C9
CA
CB to DB
Fixed data-1 (Initialized data)
DC
Fixed data-2
DD to E5
Fixed data-1 (Initialized data)
E6
Fixed data-2
E7 to FF
Fixed data-1 (Initialized data)
4.
9 Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to B7
Fixed data-1 (Initialized data)
B8
B9
Fixed data-2
BA to BC
Fixed data-1 (Initialized data)
BD
BE
Fixed data-2
BF to FF
Fixed data-1 (Initialized data)
5.
C Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Address
Initial value
Remark
NTSC PAL
10
EE
EE
11
00
00
Switching position adj.
12
00
00
13
00
00
14, 15
Fixed data-1 (Initialized data)
16
E0
E0
CAP FG duty adj.
17 to 24
Fixed data-1 (Initialized data)
25
70
-
S VIDEO OUT Y level adj. (NTSC)/
Fixed data-1 (PAL)
26
8A
-
S VIDEO OUT chroma level adj. (NTSC)/
27
61
-
Fixed data-1 (PAL)
28 to 30
Fixed data-1 (Initialized data)
31
Fixed data-2
32, 33
Fixed data-1 (Initialized data)
34
80
80
VCO adj. (EVF)
35
8A
8A
36 to 39
Fixed data-1 (Initialized data)
3A
93
93
White balance adj. (EVF)
3B
7F
7F
3C
82
82
Contrast adj. (EVF)
3D to 3F
Fixed data-1 (Initialized data)
40
Fixed data-2
41
Fixed data-1 (Initialized data)
42
Fixed data-2
43
Fixed data-1 (Initialized data)
44
Fixed data-2
45
64
64
VCO adj. (LCD)
46
6E
6E
47
95
95
V-COM adj. (LCD)
48 to 4A
Fixed data-1 (Initialized data)
4B
8A
8A
Transmissive mode white balance
4C
64
64
adj. (LCD)
4D
7A
7A
Contrast adj. (LCD)
4E to 53
Fixed data-1 (Initialized data)
54
3F
3F
Sample hold phase adj.
55 to 68
Fixed data-1 (Initialized data)
69
6A
Fixed data-2
6B to 6D
Fixed data-1 (Initialized data)
6E
6F
Fixed data-2
70
72
72
Reflective mode white balance
71
6A
6A
adj. (LCD)
Page of 126
Display

Click on the first or last page to see other HDR-HC5 / HDR-HC5E / HDR-HC7 / HDR-HC7E (serv.man4) service manuals if exist.