HDR-GW55VE/GW77/GW77E/GW77V/GW77VE_L2
1-5
– ENGLISH –
1-4.  AIR-LEAK TEST
1-4-1. Inspection Procedure (Compressor Type)
1.   Turn on the air-leak tester.
2.   Hold the vacuum pad on flat surface, set the air switch to “open”, and adjust the pressure to around -5.0 by turning the pressure adjustment
 knob.
 
Inspection pressure:-45.0 ±3.0 kPa
 
3.   Confirm that there is no dust on the vacuum pad and test hole, and hold the vacuum pad by pressing it vertically to the center of test hole
 on the 
camera.
 
OK
Tilt
NG
Test hole
Cover Tape (Microphone)
Microphone Sheet
Air leak
Caution :
Keep vacuum pad vertically by touching with finger. 
Do not keep pressing it to the camera.
Do not touch the tube during the measurement, or measurement
value may be changed.
Caution:
When performing air leak test, peel off the Microphone Sheet
(4-427-606-01) and stick Cover Tape (Microphone) (4-427-546-01).
After the test has been completed, peel off the Cover Tape
(Microphone) (4-427-546-01) and stick a new Microphone Sheet
(4-427-606-01).
Perform the measurement under no vibration.
It may cause the air-leak under the condition with vibration.
Body side
Panel side
4.   Wait 120 seconds with keeping the pressure at near -5.0 kPa.
5.   Wait 30 seconds with setting air switch to “close”, and write the indicated value.
6.  In addition, leave for 1 minute, and check the pressure changes value is satisfied the following value by comparing between the written indicated 
value and indicated value.
Body side
 
Specification value  0.32 kPa or less: OK
 
 
0.33 kPa or more: NG
Caution: Do not open the connector cover and the battery/memory card cover for two minutes after the leak test.
Note: If the measurement result does not meet the specification value, check the compressor setting value and retry inspection.
 
120 sec
30 sec
60 sec
-40.0 kPa
0 kPa
-45.0 kPa
-50.0 kPa
Air
pressure
-0.0 kPa
FFF
-5.0 kPa
-10.0 kPa
Indicated
value
Air switch: open
Air switch: close
Measurement
Measure this changed value.
One minute later, it is OK
if the value within 0.32 kPa.
Panel side
 
Specification value  0.07 kPa or less: OK
 
 
0.08 kPa or more: NG
Caution: Do not open the connector cover and the battery/memory card cover for two minutes after the leak test.
Note: If the measurement result does not meet the specification value, check the compressor setting value and retry inspection.
 
120 sec
30 sec
60 sec
-40.0 kPa
0 kPa
-45.0 kPa
-50.0 kPa
Air
pressure
-0.0 kPa
FFF
-5.0 kPa
-10.0 kPa
Indicated
value
Air switch: open
Air switch: close
Measurement
Measure this changed value.
One minute later, it is OK
if the value within 0.07 kPa.
HDR-GW55VE/GW77/GW77E/GW77V/GW77VE_L2
1-6
1-4-2. Inspection Procedure (Hand Pump Type)
1.  Turn on the air-leak tester.
2.  Keep the vacuum pad by pressing it to the center of test hole on the camera.
 
OK
Tilt
NG
Test hole
Cover Tape (Microphone)
Microphone Sheet
Air leak
Caution :
Keep vacuum pad vertically by touching with finger. 
Do not keep pressing it to the camera.
Do not touch the tube during the measurement, or measurement
value may be changed.
Caution:
When performing air leak test, peel off the Microphone Sheet
(4-427-606-01) and stick Cover Tape (Microphone) (4-427-546-01).
After the test has been completed, peel off the Cover Tape
(Microphone) (4-427-546-01) and stick a new Microphone Sheet
(4-427-606-01).
Perform the measurement under no vibration.
It may cause the air-leak under the condition with vibration.
Body side
Panel side
3.  Press the hand pump slightly so that the indicated pressure value becomes to “-5.0”.
 
Few seconds later, decrease the pressure slightly. Therefore adjust the indicated pressure by pressing the hand pump.
Note: Perform the pressure adjustment by hand pump pushing amount.
   
If the pressure becomes too high, perform the adjustment again after removing the vacuum pad.
 
– ENGLISH –
4   The change value is getting settle, wait 120 seconds with keeping the pressure at around the -5.0kPa (within -0.0kPa to -10.0kPa).
Caution:  Do not operate the hand pump after settling the change value.
   
If operate the hand pump again, wait 120 seconds form then.
5.  Write the indicated value, leave for 1 minute, and check the pressure changes value is satisfied the following value by comparing between written 
indicated value and indicated value.
Body side
 
Specification value  0.32 kPa or less: OK
 
 
0.33 kPa or more: NG
Caution: Do not open the connector cover and the battery/memory card cover for two minutes after the leak test.
 
120 sec
60 sec
Measurement
Vacuum by hand pump
Stop hand pump
Measure this changed value.
One minute later, it is OK
if the value within 0.32 kPa.
Measure between -0.0 to -10.0
-40.0 kPa
0 kPa
-45.0 kPa
-50.0 kPa
Air
pressure
-0.0 kPa
FFF
-5.0 kPa
-10.0 kPa
Indicated
value
Panel side
 
Specification value  0.07 kPa or less: OK
 
 
0.08 kPa or more: NG
Caution: Do not open the connector cover and the battery/memory card cover for two minutes after the leak test.
 
120 sec
60 sec
Measurement
Vacuum by hand pump
Stop hand pump
Measure this changed value.
One minute later, it is OK
if the value within 0.07 kPa.
Measure between -0.0 to -10.0
-40.0 kPa
0 kPa
-45.0 kPa
-50.0 kPa
Air
pressure
-0.0 kPa
FFF
-5.0 kPa
-10.0 kPa
Indicated
value
HDR-GW55VE/GW77/GW77E/GW77V/GW77VE_L2
1-7
1-4-3. In The Case of Inspection Result NG
Perform by following procedure
1.   Confirm that there are not any dust on the BT lid.
 
          ↓
 
Confirm that there is not any dust on the vacuum pad.
 
          ↓
 
Cover the microphone hole so as not to damage the Microphone Sheet.
 
(Cover the microphone hole with silicon sheet for radiation(4-174-010-01 etc.) )
 
          ↓
 
Expand the suction time for 60 seconds, and perform the measurement again.
2.  Check the cabinet condition, and then perform the measurement again.
3.  If there is no improvement symptom, replace the cabinet (L) assy and the cabinet (R) block assy or panel block assy, and perform the measurement 
again
1-5. PERIODIC MAINTENANCE
1-5-1. Periodic Maintenance
To maintain the water-proof performance, we recommend that once a year you take the camcorder to your dealer, or to an authorized repair shop, 
to have the sealing gasket of the battery/memory card/jack cover replaced for a fee.
Instruction manual recommends the periodic maintenance as shown above.
If there is the request for check, perform the procedure below.
Checking Items
•  Confirm that there is no air-leak.
•  Confirm that there is no strain on the exterior.
•  Confirm that there is not any dust on the BT lid.
•  Replace the BT Lid packing.
1-5-2. Replacing the BT Lid Packing
1.  Remove the two fixed screws of BT Lid Packing.
Screw
– ENGLISH –
2.  Remove the packing, and confirm that there is no scratch such as defect on the BT Lid Cover or BT Lid Packing Fixed Plate.
Screw
Packing (BT Lid)
3.  Install the new BT Lid Packing. (also use the new screws)
Note: Be careful that there is no dust on the packing.
1-6.  PRECAUTION ON REPLACING THE VC-657 BOARD
Note the following when replacing the board.
Note:  When replacing the board, it is necessary to change the destination data first. 
 
To change the destination data, execute the [DESTINATION DATA WRITE] of ADJUST tab in the Adjust Manual.
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATION DATA WRITE”.
After the board replacement, the error of the built-in recording media may be displayed. In this case, execute the [DESTINATION DATA WRITE]
then the error will be cleared. If it is not cleared with [DESTINATION DATA WRITE], format the built-in recording media.
USB SERIAL SAVE
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “USB SERIAL SAVE” to get the data.
USB SERIAL No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Start the Adjust Manual in the Adjust Station and execute the “USB SERIAL No. INPUT”.
About unit with Internal Memory Model
After the board replacement, execute the procedure below first.
1.  Execute the [DESTINATION DATA WRITE] of ADJUST tab in the Adjust Manual.
2.  Execute the script files below. (Refer to the flowchart in Fig. 1)
• 11DdmMmcReadTestMINI_v4.vbe
• 11DdmMmcMakePartition_v4.vbe
Note:  Download the script files from TISS Homepage.
 
When searching in the TISS Homepage, enter “IM_VC_TOOL” for keyword in the Part Number field.
Unless these script files are executed, the following symptoms may appear.
Make sure execute the above script files.
•  The internal memory is not recognized as a media.
•  The management file saved in the internal memory model cannot be repaired.
•  The internal memory cannot be formatted.
HDR-GW55VE/GW77/GW77E/GW77V/GW77VE_L2
1-8
– ENGLISH –
START
END
Reactive the camcorder automatically
Disconnect the USB cable,
 and turnoff the power switch.
Select the "USB CONNECT" to establish 
the connection
Execute 
the "DdmMmcReadTestMINI.vbe"
(several second)
Wait until "SetOverallReadMINI OK" display
Reactive the camcorder automatically
Execute
 the "11DdmMMCMakePartition.vbe"
(several second)
Wait until "MakePartition OK" display
During the power is turning-on,
 pull-out the AC-adapter. 
Then connect the AC-adapter Again 
(It's running with blue color monitor.)
Connect to the PC with a USB cable, 
and turn on the power switch.
* by SEUS driver
Fig. 1
1-7.  ADDITION OF DESTINATION DATA FILE
If the Destination Data file included in the Adjust manual is old, “DESTINATION DATA WRITE” cannot be executed in some cases.
In that case, download a new Destination Data file from the TISS homepage according to the following procedure.
Note 1:  To perform Destination Data Write for this model, the Adjust manual of the DSC-WX50 series must have been installed.
 
Install the Adjust manual of the DSC-WX50 series in advance.
Note 2:  The actual image may differ from the image shown above.
1)  If the Destination Data file in the Adjust manual in use is old, the window shown in Fig. 1 is displayed.
 
Click the [OK] button.
 Fig. 
1
2)  The Destination Data Write window opens.
 
Check the version of the Destination Data file retained in the Adjust manual.
Destination Ver. window
Page of 43