DOWNLOAD Sony HDR-CX405 / HDR-CX440 / HDR-PJ410 / HDR-PJ440 Service Manual ↓ Size: 3.91 MB | Pages: 62 in PDF or view online for FREE

Model
HDR-CX405 HDR-CX440 HDR-PJ410 HDR-PJ440
Pages
62
Size
3.91 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
hdr-cx405-hdr-cx440-hdr-pj410-hdr-pj440.pdf
Date

Sony HDR-CX405 / HDR-CX440 / HDR-PJ410 / HDR-PJ440 Service Manual ▷ View online

Manual Structure
Purpose of this manual
This manual describes the information items that premise the service based on the components parts assuming use of
system and service engineers.
Related manuals
Besides this manual, the following manuals are available.
• Operating Guide (Supplied with this unit)
• Help Guide (Web manual)
Help Guide is an on-line manual.
Refer to it for in-depth instructions on the many functions of the camcorder.
• Adjust Manual (Available on request)
The adjustment software is necessary for adjustment and various checking of this unit for the service.
HDR-CX405/HDR-CX440/HDR-PJ410/HDR-PJ440
3
Section 1
Trouble Shooting
1-1. 
Self-diagnosis Function
1-1-1. 
Self-diagnosis Function
If an error occurs in this unit, the self-diagnosis function starts working and a code consisting of one alphabet and a four-
digit number appears on the LCD. Classification of persons in charge, classification of faulty blocks, and details of errors
can be checked by referring to this indication of five alphanumeric characters in the self-diagnosis code table.
The history of past errors can be checked in “Usage and Diag record” on the DATA tab of the Adjust Manual.
The self-diagnosis function is also described in the operation manual.
1-1-2. 
Note on the Function of Boards
The boards and functions used in this model are mentioned in the following table.
Board
Function
CM board
Imager
MM board
Internal memory
WF board
Wireless LAN module
PJ board
Projector
VC board
CPU, Power, Lens drive, 3-axis angular velocity sensor, Other function
1-1-3. 
Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
0 4
0 0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0 6
0 0
The battery pack temperature is
high.
Change the battery pack or place it in a cool place.
C
1 3
0 1
Memory card is unformatted or
memory card is broken.
Format the memory card.
Insert a new memory card.
C
1 3
0 2 
*1
Access error
Remove the power source. Reconnect it again and operate
the unit again.
C
1 3
0 3 
*1
Access error (External media)
Turn power off and turn power on again.
C
1 3
0 4 
*1
Abnormality of the drive (External
media)
Turn power off and turn power on again.
C
3 2
6 0
Difficult to adjust focus
(Cannot initialize focus)
Turn power off and turn power on again. When this error is
not cleared, the focus control signal for the lens block may
be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
E
2 0
0 0
Flash memory data are rewritten.
Make flash memory data correct value. 
*2
E
3 1
0 0 
*1
Abnormality of the drive
Turn power off and turn power on again.
Continued
*1:
Function of this code is not provided in this unit.
*2:
Start the Adjust Manual in the Adjust Station and execute the “Destination data write” on the ADJUST tab.
HDR-CX405/HDR-CX440/HDR-PJ410/HDR-PJ440
1-1
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
4 1
0 0
Abnormality of the wireless LAN
module or CPU
The peripheral circuit of between CPU and wireless LAN
module may be faulty.
Replace the board that contains this peripheral circuit.
E
6 1
0 0
Difficult to adjust focus
(Cannot initialize focus)
Turn power off and turn power on again. When this error is
not cleared, the focus control signal for the lens block may
be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
E
6 1
1 0
Zoom operations fault
(Cannot initialize zoom lens)
Turn power off and turn power on again. When this error is
not cleared, operate the zoom lever and check following
items.
• When zooming is performed, the zoom control signal
for the lens block may be faulty.
• When zooming is not performed, the zoom motor
drive circuit may be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
E
6 1
1 1
Focus or zoom fault
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis
code.
E
6 1
3 0
Reset position detection error on the
stepper iris initializing
Turn the power on to open lens barrier. Disconnect the bat-
tery or power cord, and then connect again. And confirm
that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive cir-
cuit in lens drive block. If iris blades work normally, con-
firm that they are closing completely and confirm following
items.
• Case of the iris blades do not close normally. Replace
the lens block.
• Case of “E: 61: 30” is appeared and iris blades closed
completely. Confirm that communication with lens
block is normal.
• Case of LCD is not displayed normally, check that
connection between imager board and main board.
• Case of LCD is displayed normally, replace the lens
block.
E
6 1
3 1
Error in detection of the Reset Posi-
tion at the time of Stepper IR Filter
initialization
Check the signal line connection between the lens block and
the lens control circuit.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
E
6 2
0 0
Steadyshot does not work well.
(With PITCH angular velocity sen-
sor output stopped)
The peripheral circuit of the PITCH angular velocity sensor
may be faulty.
Replace the board that contains this peripheral circuit.
E
6 2
0 1
Steadyshot does not work well.
(With YAW angular velocity sensor
output stopped)
The peripheral circuit of the YAW angular velocity sensor
may be faulty.
Replace the board that contains this peripheral circuit.
E
6 2
0 2
Abnormality of IC for steadyshot.
Check signal line connections from CPU through steady-
shot IC to PITCH/YAW drive.
When there is no problem with the connections, replace the
board that contains this peripheral circuit.
E
6 2
0 3
Communication error of steadyshot
IC and CPU
The steadyshot circuit may be faulty.
Replace the board that contains this peripheral circuit.
E
6 2
0 4
Image vibration correction during
steadyshot does not work.
The image vibration angular velocity sensor (ROLL SEN-
SOR) peripheral circuit may be faulty.
Replace the board that contains this peripheral circuit.
Continued
HDR-CX405/HDR-CX440/HDR-PJ410/HDR-PJ440
1-2
Page of 62
Display