Movie / SECTION 6 ADJUSTMENTS
File
hdr-cx11e-hdr-cx12-hdr-cx12e-sm3.pdf
Date

Sony HDR-CX11E / HDR-CX12 / HDR-CX12E (serv.man3) Service Manual ▷ View online

6-28
HDR-CX11E/CX12/CX12E_ADJ
Preparation:
1) Read the PITCH sensor (LD-241 board SE9001) sensitivity
written on repair parts, and named this as S
9001
.
2) Read the YAW sensor (VC-535 board SE1001) sensitivity writ-
ten on repair parts, and named this as S
1001
.
Fig. 6-1-17
How to read the sensitivity data of angular velocity sen-
sor
With the pins 1 and 2 of angular velocity sensor placed in the
lower position, read the data value.
Description example:
For the sensor sensitivity value 60
Fig. 6-1-18
6 0
Hand Writing
1
2
4
3
11. CAMERA Adjustment 8
Perform this adjustment only when replacing the GYRO sensor or
lens block. When the microprocessor, circuit etc. is damaged, don't
perform this adjustment but check the operations only.
11-1. Preparation when the GYRO sensor, LD-241
board, or VC-535 board is replaced
Note down the sensitivity displayed on the GYRO sensor of the re-
pair parts. At this time, note down also to which board it was attached
to.
Be sure to check because if attached incorrectly, the screen will vi-
brate up and down or left and right during the steady shot operations.
Precautions on the Parts Replacement
The PITCH sensor and the YAW sensor are different parts.
Precautions on GYRO Sensor
The sensor incorporates a precision oscillator. Handle it with care as
if it dropped, the balance of oscillator will be disrupted and opera-
tions will not be performed properly.
Adjustment Block
11
Adjustment Page
8F
Adjustment Address
FF70, FF71
Note:
The sensor sensitivity of SE9001 on the LD-241 board and
SE1001 on the VC-535 board is written on the repair parts
only.
SE9001
PP
LD-241 BOARD (SIDE B)
PP: PITCH sensor
       sensitivity     S
9001
12
43
SE1001
VC-535 BOARD (SIDE B)
YY: YAW sensor
       sensitivity     S
1001
YY
1
2
43
Note:
If the VC-535 board was replaced, replace the LD-241
board at the same time, or replace the GYRO sensor
with the repair part.
6-29
HDR-CX11E/CX12/CX12E_ADJ
11-3. GYRO Sensor Sensitivity Adjustment
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 8, and the fol-
lowing screen will appear.
2) Input the sensitivity of respective sensors (S
9001
, S
1001
) read at
“Preparation” into the screen.
If only either sensor was replaced, give a check to the checkbox
for the sensor not replaced at the lower left of the screen.
3) Input the PITCH/YAW data of lens (L
1
, L
2
) read at “Prepara-
tion” into the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
Note:
In order to get the correct value for the adjustment, it is
necessary to input a decimal point (“period” or  “com-
ma”) as same format as windows setting because “Nu-
meric Value Format” depend on the language. (F:123
456 789,00, GB:123,456,789.00, D:123.456.789,00)
“Numeric Value Format” setting is available in “Con-
trol Panel”-“Regional and Language Options”.
4) Click the [OK] button, and the adjustment data is then calcu-
lated from the sensor sensitivity value and the calculation re-
sult is written to the memory in the camera.
5) Upon successful completion of the data writing, the following
massage will be displayed, and then turn off the power of cam-
era and turn it on again.
6) After the Camera started, click the [OK]  button of the mes-
sage, and the data value will be clecked. If the data value is
normal, the following massage will be displayed. Check that
the steady shot function operates normally.
11-2. Preparation when the lens is replaced
Note down the PITCH/YAW data on the replacement lens for repair.
Adjustment Block
11
Adjustment Page
8F
Adjustment Address
FF70, FF71
Note:
The PITCH/YAW data of lens is written only repair parts.
Preparation:
1) Read the PITCH data written on repair parts, and named this
as L
1
.
2) Read the YAW data written on repair parts, and named this as
L
2
.
Fig. 6-1-19
YAW data    
t
 L
2
PITCH/YAW Data
PITCH data 
t
 L
1
P.PP / Y.YY
P.PP / Y.YY
6-30
HDR-CX11E/CX12/CX12E_ADJ
1-7.
LCD  SYSTEM  ADJUSTMENTS
1.
Function of Each Button on LCD System Adjust-
ment Screen
Click the [LCD SYSTEM ADJUSTMENT] button on the Main Menu
screen, and the “LCD SYSTEM ADJUSTMENT” screen in Fig.
6-1-20 will appear.
Fig. 6-1-20
1
[To Menu] button
The Main Menu screen comes back.
2
[Start] button
Each adjustment “LCD Adjustment” or “Touch Panel Adjust-
ment” starts.
2.
Adjustment Items of LCD System Adjustment
The adjustment items of LCD system adjustment are as listed in
Table 6-1-5. The Automatic Adjustment Program executes the ad-
justment items if the LCD Adjustment Start button is clicked.
Table 6-1-5
Block
Page
Address
VCO Adj.
10
60
1050 (NTSC model),
1051 (PAL model)
Contrast Adj.
10
60
1058
V-COM Adj.
10
60
1052
Transmissive Mode White Balance Adj.
10
60
1056, 1057
Reflective Mode White Balance Adj.
10
60
107B, 107C
Sample Hold Phase Adj.
10
60
105F
Touch Panel
Adjustment
Touch Panel Adj.
Adjusting Address
(Note)
Button Name
Adjustment
LCD
Adjustment
Note:
The adjustment data cannot be read or written from the SeusEX.
2
1
6-31
HDR-CX11E/CX12/CX12E_ADJ
4) If the [End] button is clicked, the following screen is displayed
during the execution of “4. Transmissive Mode White Balance
Adj.”. Check that the LCD screen is not colored. If colored,
using the [Up]/[Down] button on the screen, adjust so that the
LCD screen is not colored. After the adjustment, click the [End]
button in the screen.
5) If the [End] button is clicked, “5. Reflective Mode White Bal-
ance Adj.” and “6. Sample Hold Phase Adj.” will be executed.
The following screen is displayed during the execution of “6.
Sample Hold Phase Adj.”. Using the [Up]/[Down]  button on
the screen, adjust so that the 2nd portion A of the LCD screen
is Brightest. After the adjustment, click the [End] button in the
screen.
6) If the [End] button is clicked, “7. Release of Data Setting dur-
ing LCD Adj.” will be executed.
7) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the [OK] button.
3.
LCD Adjustment
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD Adj.
2. LCD Automatic Adj.
(VCO Adj., Contrast Adj.)
3. V-COM Adj.
4. Transmissive Mode White Balance Adj.
5. Reflective Mode White Balance Adj.
6. Sample Hold Phase Adj.
7. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the [Start] button of the LCD Adjustment.
2) The Automatic Adjustment Program executes the “1. Data
Setting during LCD Adj.” and “2. LCD Automatic Adj.”.
3) After that, the following screen is displayed during the execu-
tion of “3. V-COM Adj.”. Using the [Up]/[Down] button on the
screen, adjust so that the brightness of portions A and B on the
LCD panel is equal. After the adjustment, click the [End] but-
ton in the screen.