DOWNLOAD Sony DCR-TRV38 / DCR-TRV38E / DCR-TRV39 (serv.man4) Service Manual ↓ Size: 1.31 MB | Pages: 66 in PDF or view online for FREE

Model
DCR-TRV38 DCR-TRV38E DCR-TRV39 (serv.man4)
Pages
66
Size
1.31 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv38-dcr-trv38e-dcr-trv39-sm4.pdf
Date

Sony DCR-TRV38 / DCR-TRV38E / DCR-TRV39 (serv.man4) Service Manual ▷ View online

6-18
DCR-TRV38/TRV38E/TRV39
3. E Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Table. 6-1-10.
Address
Remark
00 to 07
08
09
0A to 0C
0D
0E
0F to 10
11
12 to 18
19
1A
1B
1C
1D
1E to 1F
20
21
22
23
24 to 45
46
47
48 to 53
54
55
56 to 5A
5B
5C to 65
66
67
68
69
6A to 6E
6F
70
71
72 to B1
B2
B3 to BC
BD
BE to ED
EE
EF
F0
F1
F2
F3
F4
F5
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Address
Remark
F6
F7
F8
F9
FA to FE
FD
FE to FF
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
6-19
DCR-TRV38/TRV38E/TRV39
4. F Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Address
Remark
Initial value
Initial value
NTSC PAL
00 to FF
10
11 to 12
13
14
15
16
17
18
19
1A
1B
1C to 2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A to 3F
40
41
42 to 44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
40
28
70
88
40
80
88
A0
59
9E
28
CF
07
E6
19
DA
0D
AD
45
2C
FF
E7
3F
10
39
C2
1E
2E
00
00
00
00
6E
19
00
48
00
00
00
40
28
70
88
40
80
88
A0
59
9E
2B
26
08
8A
1B
3C
0E
6D
48
2E
FE
E1
3F
10
39
C2
1E
2E
00
00
00
00
6E
19
00
48
00
00
00
54MHz/66MHz origin osc. adj.
Fixed data-1
HALL adj.
MAX GAIN adj.
LV standard data input
Fixed data-1
AWB standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Flange back adj.
Address
Remark
Initial value
Initial value
NTSC PAL
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66 to 71
72
73
74 to 75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C to 91
92
93 to 97
98
99
9A
9B
9C
9D to A5
A6
A7 to AA
AB
AC to AF
B0
B1 to CC
80
80
80
80
40
C0
40
C0
40
C0
40
C0
40
00
34
00
30
00
2A
00
1C
00
40
3A
31
31
35
1E
80
80
80
80
80
80
19
80
80
80
80
40
C0
40
C0
40
C0
40
C0
40
00
34
00
30
00
2A
00
17
00
40
3A
31
31
35
1E
80
80
80
80
80
80
19
Fixed data-1
MR adj.
Fixed data-1
Fixed data-2
Fixed data-1
Mechanical shutter adj.
Fixed data-1
Hall adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
6-20
DCR-TRV38/TRV38E/TRV39
6. 1F Page Table
Note1: When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Address
Remark
Initial value
Initial value
NTSC PAL
F Page
CD
CE
CF
D0
D1 to F8
F9
FA
FB
FC to FF
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Table. 6-1-11.
5. 1E Page Table
Note1: When reading or writing the 1E page data, select page: 0, address:
10, and set data: 01, then select E page. The 1E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Table. 6-1-12.
Address
Remark
00 to C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2 to D7
D8
D9
DA
DB
DC to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Table. 6-1-13.
Address
Remark
00
00 to AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5 to B7
B8
B9
BA
BB to BD
BE
BF
C0 to C9
CA
CB
CC
CD
CE
CF to D6
D7
D8 to DC
DD
DE
DF to F2
F3
F4 to FF
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
6-21
DCR-TRV38/TRV38E/TRV39
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for “54MHz/
66MHz Origin Oscillation Adjustment”), check that the specified
values of “VIDEO SYSTEM ADJUSTMENTS” are satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
1. 54MHz/66MHz Origin Oscillation Adjustment
(VC-315 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin qh of IC1503
Or Pin <zc.> of IC2101 (R2132)
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified Value
Pin qh of IC1503
f=33000000 
±
 165Hz (NTSC)
f=27000000 
±
 136Hz (PAL)
Pin <zc.> of IC2101 (R2132)
f=13500000 
±
 68Hz
Note1: The data of page: 0, address: 10 must be “00”.
Note2: When open the DI-089 board, use the following extension cable
between the VC-315 board CN1003 and DI-089 board CN4004.
J-6082-352-A (100P, 0.5mm)
Note3: NTSC model: DCR-TRV38/TRV39
PAL model: DCR-TRV38E
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
10
Change the data and set the
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Set the data.
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
13 to 18, 92
Specified Value 1
D4 to DC
Specified Value 2
24 to 2C
Specified Value 3
D2 to DE
Specified Value 4
22 to 2E
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Note2: The data of page: 0, address: 10 must be “00”.
Switch setting:
POWER ......................................................................... CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
6D
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note3)
4
6
01
00
Set the data, and press PAUSE
button.
Note3: The adjustment data will be automatically input to page: F, address:
13 to 18, 92.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
6
01
03
Set the data, and press PAUSE
button.
4
1
Check that the IRIS display data
(Note1) satisfies the specified value1.
5
6
01
01
Set the data, and press PAUSE
button.
6
1
Check that the IRIS display data
(Note1) satisfies the specified value2.
7
6
01
6B
Set the data, and press PAUSE
button.
8
6
01
69
Set the data, and press PAUSE
button.
9
1
Check that the ND display data
(Note1) satisfies the specified value3.
10
6
01
6B
Set the data, and press PAUSE
button.
11
1
Check that the ND display data
(Note1) satisfies the specified value4.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
03
00
Set the data.
3
0
01
00
Set the data.
Fig. 6-1-7.
COVER
COVER
IC2101
IC1503
24
25
36
12
1
13
37
48
R2132
VC-315 board
Page of 66
Display