Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv38-dcr-trv38e-dcr-trv39-sm4.pdf
Date

Sony DCR-TRV38 / DCR-TRV38E / DCR-TRV39 (serv.man4) Service Manual ▷ View online

6-34
DCR-TRV38/TRV38E/TRV39
Order Page Address Data
Procedure
16
Calculate D
36
 using following
equation (Hexadecimal
calculation). (Note3)
D
36
 = PRESET DATA + 18
17
C
36
D
36
Set the data, and press PAUSE
button.
18
Return to step 7.
19
C
36
Set the PRESET DATA and
press PAUSE button.
20
C
36
Read the data, and this data is
named D
36
.
21
Calculate D
37
 using following
equation (Hexadecimal
calculation).
D
37
 = D
36
 + 18 (NTSC) (Note4)
D
37
 = D
36
 – 18 (PAL) (Note5)
22
C
37
D
37
Set the data, and press PAUSE
button.
23
C
5A
F3
Set the data, and press PAUSE
button.
24
3
0C
00
Set the data, and press PAUSE
button.
25
3
22
00
Set the data, and press PAUSE
button.
26
0
01
00
Set the data.
Note2: When D
36
 become negative number, handle D
36
 as “00”.
Note3: When D
36
 become above “FF”, handle D
36
 as “FF”.
Note4: When D
37
 become above “FF”, handle D
37
 as “FF”.
Note5: When D
37
 become negative number, handle D
37
 as “00”.
1-2. Manual Adjustment
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin qa of CN1004 of VC-315 board
(EVF VCO)
Measuring Instrument
Frequency counter
Adjustment Page
C
Adjustment Address
36, 37
Specified Value
f = 15734 
±
 30Hz (NTSC)
f = 15625 
±
 30Hz (PAL)
Note1: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
36
Change the data and set the VCO
frequency (f) to the specified value.
3
C
36
Press PAUSE button.
4
C
36
Read the data, and this data is
named D
36
.
5
Convert D
36
 to decimal notation,
and obtain D
36
’. (Note2)
6
Calculate D
37
’ using following
equations (Decimal calculation)
[NTSC model]
When D
36
 
 231
D
37
’=D
36
’+24
When D
36
’>231
D
37
’=255
[PAL model]
When D
36
 
 24
D
37
’=D
36
’–24
When D
36
’ < 24
D
37
’=0
7
Convert D
37
’ to a hexadecimal
number, and obtain D
37
. (Note2)
8
C
37
D
37
Set the data, and press PAUSE
button.
9
0
01
00
Set the data.
Note2: Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.
6-35
DCR-TRV38/TRV38E/TRV39
2. RGB AMP Adjustment (DI-089 board)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Note: Do either of the automatic adjustment or the manual adjustment.
2-1. Automatic Adjustment
Mode
Camera
Subject
Arbitrary
Adjustment Page
C
Adjustment Address
39
Note: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
01
50
Set the data, and press PAUSE
button.
3
3
02
Check that the data changes from
“50” to “00”.
4
3
01
00
Set the data, and press PAUSE
button.
5
0
01
00
Set the data.
2-2. Manual Adjustment
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin qd of CN1004 of VC-315 board
(EVF VG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
39
Specified Value
A = 7.00 
±
 0.05V
Note: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
39
Change the data and set the
voltage (A) between the reversed
waveform pedestal and non-
reversed waveform pedestal to the
specified value.
3
C
39
Press PAUSE button.
4
0
01
00
Set the data.
Pedestal
Pedestal
A
2H
Fig. 6-1-15.
6-36
DCR-TRV38/TRV38E/TRV39
3. Contrast Adjustment (DI-089 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Note: Do either of the automatic adjustment or the manual adjustment.
3-1. Automatic Adjustment
Mode
Camera
Subject
Arbitrary
Adjustment Page
C
Adjustment Address
3E
Note: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
01
51
Set the data, and press PAUSE
button.
3
3
02
Check that the data changes from
“51” to “00”.
4
3
01
00
Set the data, and press PAUSE
button.
5
0
01
00
Set the data.
3-2. Manual Adjustment
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin qd of CN1004 of VC-315 board
(EVF VG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
3E
Specified Value
A = 2.40 
±
 0.05V
Note: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
3E
Change the data and set the
voltage (A) between the 100 IRE
and 0 IRE (pedestal) to the
specified value. (The data should
be “00” to “7F”.)
3
C
3E
Press PAUSE button.
4
0
01
00
Set the data.
100 IRE
Pedestal
A
2H
Fig. 6-1-16.
6-37
DCR-TRV38/TRV38E/TRV39
4. White Balance Adjustment (DI-089 board)
Correct the white balance.
If deviated, the reproduction of the EVF screen may degenerate.
Mode
Camera
Subject
Arbitrary
Measurement Point
Check on EVF screen
Measuring Instrument
Adjustment Page
C
Adjustment Address
3C, 3D
Specified Value
The EVF screen should not be colored.
Note1: Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC3202
Note2: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
3C
80
Set the data, and press PAUSE
button.
3
C
3D
80
Set the data, and press PAUSE
button.
4
C
3D
Check that the EVF screen is not
colored. If not colored, proceed to
step 10.
5
C
3C
Change the data so that the EVF
screen is not colored.
6
C
3C
Press PAUSE button.
7
C
3D
Change the data so that the EVF
screen is not colored.
8
C
3D
Press PAUSE button.
9
C
3D
If the EVF screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.