Sony DCR-TRV38 / DCR-TRV38E / DCR-TRV39 (serv.man4) Service Manual ▷ View online

6-10
DCR-TRV38/TRV38E/TRV39
4. D Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Table. 6-1-3.
00 to 0F
10
11
12
13
14 to 15
16
17 to 19
2A
2B to 37
38
39
3A
3B to 55
56
57
58
59
5A to 63
64
65
66 to 6E
6F
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Address
Remark
Initial value
6-11
DCR-TRV38/TRV38E/TRV39
1-2-2.
INITIALIZATION OF B, 1B PAGE DATA
Note: When reading or writing the B page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the B, 1B Page Data
Note1: If “Initializing the B, 1B Page Data” is performed, all data of the
B page and 1B page will be initialized. (It is impossible to initialize
a single page.)
Note2: If the B, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of B, 1B page data
Note3: The power supply voltage must be 6.3 
±
 0.1Vdc.
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
5
02
FF
Set the data, and press PAUSE
button.
4
5
01
F3
Set the data, and press PAUSE
button.
5
5
00
01
Set the data, and press PAUSE
button.
6
5
02
Check that the data changes to
“00”.
7
Perform “Modification of B, 1B
Page Data”.
2. Modification of B, 1B Page Data
If the B, 1B page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the B page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1B page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1B page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B, 1B Page data:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
3. Writing the Network Default Setting Value
(DCR-TRV39)
Writing method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
5
0E
00
Set the data, and press PAUSE
button.
4
5
01
F8
Set the data, and press PAUSE
button.
5
5
00
01
Set the data, and press PAUSE
button.
6
5
0E
Check that the data is “01”.
7
0
01
00
Set the data.
6-12
DCR-TRV38/TRV38E/TRV39
4. B Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
Page Data”).
Table. 6-1-4.
5. 1B Page Table
Note1: When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
Page Data”).
Address
Remark
00 to 02
03
04 to AA
AB
AC to AF
B0
B1 to B6
B7
B8 to BA
BB
BC
BD
BE to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-5.
Address
Remark
00
01 to FF
Fixed data-2
Fixed data-1
6-13
DCR-TRV38/TRV38E/TRV39
1-2-3.
INITIALIZATION OF 8, C, 18, 1C PAGE DATA
Note: When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 18, 1C page data, select page: 0, address:
10, and set data: 01, then select 8 or C page. The 18 or 1C page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 8, C, 18, 1C Page Data
Note1: If “Initializing the 8, C, 18, 1C Page Data” is performed, all data
of the 8 page, C page, 18 page and 1C page will be initialized. (It
is impossible to initialize a single page.)
Note2: If the 8, C, 18, 1C page data has been initialized, following
adjustments need to be performed again.
1) Modification of 8, C, 18, 1C page data
2) Viewfinder system adjustments
3) LCD system adjustments
4) Serial No. input
5) Servo and RF system adjustments
6) Video system adjustments
Note3: The power supply voltage must be 6.3 
±
 0.1Vdc.
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
18
Adjusting Address
00 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C,
18, 1C Page Data”.
2. Modification of 8, C, 18, 1C Page Data
If the 8, C, 18, 1C page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 18, 1C page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 18, 1C page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C, 18, 1C Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.