Sony DCR-TRV16 / DCR-TRV16E / DCR-TRV18 / DCR-TRV18E Service Manual ▷ View online

5-24
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
7. Picture Frame Setting
Subject
Color bar chart
(Color reproduction adjustment frame)
(1.5m from the front of the lens)
Measurement Point
Video output terminal
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, E=F
Note1:
The following adjustments should be carried out upon completion
of “Flange back adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Setting method:
1)
Select page: 6, address: 48, and set data: 01.
2)
Adjust the zoom and the camera direction, and set to the
specified position.
3)
Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “Color reproduction adjustment frame”.
Processing after Completing Camera System Adjustments:
After completing the camera system adjustments, release the data
settings.
1)
Select page: 6, address: 48, and set data: 00.
Check on the oscilloscope
1. Horizontal period
Fig. 5-1-10.
2. Vertical period
Fig. 5-1-11.
Check on the monitor TV (Underscanned mode)
Fig. 5-1-12.
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
5-25
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
8. Color Reproduction Adjustment
Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment frame)
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
33, 35, 3A, 3B
Specified Value
All color luminance points should
settle within each color reproduction
frame.
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
NTSC model: DCR-TRV16/TRV18
PAL model: DCR-TRV16E/TRV18E/TRV116E/TRV118E
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 48, and set data: 01.
3)
Select page: 6, address: 9D, and set data: 29.
4)
Select page: 6, address: 01, set data: 3D, and press the PAUSE
button.
5)
Select page: F, address: D0, set the following data, and press
the PAUSE button.
37 (NTSC), B7 (PAL)
6)
Adjust the GAIN and PHASE of the vectorscope, and adjust
the burst luminance point to the burst position of the color
reproduction frame.
7)
Change the data of page: F, address: 33, 35, 3A and 3B, and
settle each color luminance point in each color reproduction
frame.
Note:
Be sure to press the PAUSE button of the adjustment remote
commander before changing the addresses. If not, the new data
will not be written to the memory.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 6, address: 48, and set data: 00.
3)
Select page: 6, address: 9D, and set data: 00.
4)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-13.
Burst position
Burst position
For PAL model
For NTSC model
5-26
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
9. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
1D
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
01
Set the data.
3
6
96
27
Set the data.
4
6
97
00
Set the data.
5
6
01
6F
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note3)
Note3:
The adjustment data will be automatically input to page: F, address:
1D.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
48
00
Set the data.
2
6
96
00
Set the data.
3
6
97
00
Set the data.
4
6
01
00
Set the data, and press PAUSE
button.
5
0
01
00
Set the data.
10. Auto White Balance & LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1E, 1F, 2A to 2D
Specified Value
0FF0 to 1010
Note1:
This adjustments should be carried out upon completion of  “Color
reproduction adjustment” and “MAX GAIN adjustment”.
Note2:
After the power is turned on, this adjustment can be done only
once.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note5:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
01
Set the data.
3
Wait for 2 sec.
4
6
01
11
Set the data, and press PAUSE
button.
5
6
01
0D
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note6)
7
0
03
1E
Set the data.
8
1
Check that the display data
(Note5) satisfies the specified
value.
Note6:
The adjustment data will be automatically input to page: F, address:
1E, 1F, 2A to 2D.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
0
03
00
Set the data.
4
0
01
00
Set the data.
5
Perform “Auto White Balance
Adjustment”.
5-27
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
11. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
2E, 2F
Specified Value
R ratio: 2B40 to 2C40
B ratio: 5980 to 5A80
Note1:
This adjustments should be carried out upon completion of “Auto
White Balance & LV Standard Data Input”.
Note2:
After the power is turned on, this adjustment can be done only
once.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the lens.
2
0
01
01
Set the data.
3
6
48
01
Set the data.
4
F
3E
Write down the data.
5
F
3E
2B
Set the data, and press PAUSE
button.
6
F
3F
Write down the data.
7
F
3F
C0
Set the data, and press PAUSE
button.
8
F
40
Write down the data.
9
F
40
5A
Set the data, and press PAUSE
button.
10
F
41
Write down the data.
11
F
41
00
Set the data, and press PAUSE
button.
12
6
01
83
Set the data, and press PAUSE
button.
13
6
01
81
Set the data, and press PAUSE
button.
14
6
02
Check that the data changes to
“01”. (Note5)
15
6
01
3F
Set the data, and press PAUSE
button.
16
0
03
04
Set the data.
17
1
Check that the display data
(Note4) satisfies the R ratio
specified value.
18
0
03
05
Set the data.
1
Check that the display data
(Note4) satisfies the B ratio
specified value.
Note5:
The adjustment data will be automatically input to page: F, address:
2E, 2F.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
F
3E
Set the data that is written down
at step 3, and press PAUSE button.
4
F
3F
Set the data that is written down
at step 5, and press PAUSE button.
5
F
40
Set the data that is written down
at step 7, and press PAUSE button.
6
F
41
Set the data that is written down
at step 9, and press PAUSE button.
7
0
03
00
Set the data.
8
0
01
00
Set the data.
Page of 127
Display

Click on the first or last page to see other DCR-TRV16 / DCR-TRV16E / DCR-TRV18 / DCR-TRV18E service manuals if exist.