5-16
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
3. E Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
Table. 5-1-8.
Address
00 to 10
11
12 to 14
15
16
17
18 to 1B
1C
1D
1E to 36
37
38 to 3C
3D
3E to 6E
6F
70 to 94
95
96 to 97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2 to AD
AE
AF to C1
C2
C3 to E8
E9
EA
EB
EC
ED
EE
EF to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
4. F Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
Address
Remark
Initial value
Initial value
NTSC PAL
00 to 0F
10 to 11
12
13 to 16
17
18
19
1A to 1C
1D
1E
1F
20 to 29
2A
2B
2C
2D
2E
2F
30 to 32
33
34
35
36 to 39
3A
3B
3C to 45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57 to 5B
5C
5D
5E
5F to 61
80
81
5D
17
9A
80
7A
4D
3E
64
59
96
7A
22
27
00
F1
19
51
20
22
13
93
00
00
00
00
46
19
00
2A
00
00
00
00
80
81
5D
17
9A
80
7A
90
3E
43
59
80
40
22
24
00
EF
19
51
20
22
13
93
00
00
00
00
46
19
00
2A
00
00
00
00
Fixed data-1
36MHz origin osc. adj.
Fixed data-1
HALL adj.
Fixed data-1
MAX GAIN adj.
AWB & LV standard data input
Fixed data-1
AWB & LV standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Flange back adj.
Fixed data-1
Fixed data-2
Optical axis adj.
Fixed data-1
5-17
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
00
00
00
80
80
80
80
80
80
40
00
34
00
30
00
2A
00
28
00
70
80
80
80
80
1E
00
00
00
80
80
80
80
80
80
40
00
34
00
30
00
2A
00
28
00
70
80
80
80
80
1E
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C to 92
93
94
95 to 9E
9F
A0 to C3
C4
C5 to C9
CA
CB
CC to D9
DA
DB to DD
DE
DF to E7
E8
E9
EA to EB
EC
ED to F4
F5
F6
F7
F8 to FF
Fixed data-1
Mechanical shutter adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 5-1-9.
5. 1F Page Table
Note1:
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
F page
00
01
02 to 05
06
07
08
09
0A to 51
52
53 to 56
57
58 to 59
5A
5B
5C
5D to 64
65
66 to 6B
6C
6D
6E
6F
70 to 73
74
75 to 77
78
79
7A to 7F
80
81 to 97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4 to B0
B1
B2
B3
B4 to B9
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
Initial value
NTSC PAL
Address
Remark
5-18
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
Address
Remark
BA
BB to CB
CC
CD
CE
CF
D0
D1 to D9
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
1F page
Table. 5-1-10.
5-19
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for “36MHz
Origin Oscillation Adjustment”), check that the specified values of
“VIDEO SYSTEM ADJUSTMENTS” are satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
1. 36MHz Origin Oscillation Adjustment (VC-280 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin qs of IC1402
Or Pin eg of IC2401
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
12
Specified Value
Pin qs of IC1402
f=18000000 ± 90Hz
Pin eg of IC2401
f=13500000 ± 68Hz
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
When open the VA-117 board, use the following extension cable
between the VC-280 board CN1007 and VA-117 board CN4002.
J-6082-352-A (100P, 0.5mm)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
12
Change the data and set the
frequency (f) to the specified
value.
3
F
12
Press PAUSE button.
4
0
01
00
Set the data.
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
17, 18, 19
Specified Value 1
15 to 19
Specified Value 2
8A to 8E
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
IRIS display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
POWER ......................................................................... CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
17
Set the data.
3
6
95
8C
Set the data.
4
6
01
6D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note3)
6
6
01
00
Set the data, and press PAUSE
button.
Note3:
 The adjustment data will be automatically input to page: F, address:
17, 18, 19.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
03
00
Set the data.
5
0
01
00
Set the data.
Fig. 5-1-7.
1
12
13 24
48 37
36
25
IC1402
1
20
21
40
80
61
41
60
IC2401
VC-280 board (SIDE B)
VC-280 board (SIDE A)
Page of 127
Display

Click on the first or last page to see other DCR-TRV16 / DCR-TRV16E / DCR-TRV18 / DCR-TRV18E service manuals if exist.