Sony DCR-TRV16 / DCR-TRV16E / DCR-TRV18 / DCR-TRV18E Service Manual ▷ View online

5-8
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 1B, 1F
PAGE DATA
Note:
When reading or writing the 1B or 1F page data, select page: 0,
address: 10, and set data: 01, then select B or F page. The 1B or 1F
page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
[Connection of the power supply during the initialization of the
data.]
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-1-6.
2)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.0 ± 0.1Vdc.
3)
Turn off the power supply.
4)
Turn on the HOLD switch of the adjusting remote commander.
5)
Turn on the power supply.
6)
Perform the initialization of the data.
Note:
This is normal though the following message is indicated on
the LCD screen.
“FOR InfoLITHIUM BATTERY ONLY”
[Initialization Procedure]
1.
Initialization of A, D page data
2.
Initialization of B, 1B page data
3.
Initialization of 8, C page data
4.
Initialization of E, F, 1F page data
Fig.5-1-6.
Battery terminal
Regulated power supply
Digital volt meter
5-9
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
1-2-1.
INITIALIZATION OF A, D PAGE DATA
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the A, D Page Data
Note1:
If the A, D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of A, D page data
Note2:
The power supply voltage must be 6.0 ± 0.1Vdc.
Adjusting page
A
Adjusting Address
10 to FF
Adjusting page
D
Adjusting Address
10 to 67
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
03
Set the following data.
02 (DCR-TRV16 (NTSC))
03 (DCR-TRV18 (NTSC))
82 (DCR-TRV16E /TRV116E(PAL))
83 (DCR-TRV18E/TRV118E (PAL))
4
7
00
Set the following data.
20 (Initializing A page)
22 (Initializing D page)
28 (Initializing A and D pages)
5
7
01
Set the following data, and press
PAUSE button.
20 (Initializing A page)
22 (Initializing D page)
28 (Initializing A and D pages)
6
7
02
Check that the data changes to
“01”
7
Perform “Modification of A, D
Page Data”.
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, D Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE
button.
Note:
If the following symptoms occur after completing of the
“Modification of A, D page data”, check that the data of the “Fixed
data-2” addresses of A and D page are same as those of the same
model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
3. A Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Table. 5-1-2.
Address
00 to 0F
10 to 17
18
19
1A
1B to 2E
2F
30 to 31
32
33
34 to 51
52
53 to 59
5A
5B to CF
D0
D1
D2 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Ver 1.1  2002. 06
5-10
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
4. D Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Table. 5-1-3.
00 to 0F
10
11 to 12
13
14 to 15
16
17 to 21
22
23
24
25
26
27 to 29
2A
2B
2C
2D
2E to 36
37
38
39
3A
3B to 56
57
58
59
5A
5B
5C
5D
5E
5F to 67
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Address
Remark
Initial value
5-11
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
1-2-2.
INITIALIZATION OF B, 1B PAGE DATA
Note:
When reading or writing the B page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the B, 1B Page Data
Note1: If “Initializing the B, 1B Page Data” is performed, all data
of the B page and 1B page will be initialized. (It is
impossible to initialize a single page.)
Note2:
If the B, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of B, 1B page data
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
5
02
FF
Set the data.
4
5
01
F3
Set the data, and press PAUSE
button.
5
5
00
01
Set the data, and press PAUSE
button.
6
5
02
Check that the data changes to
“00”.
7
Perform “Modification of B, 1B
Page Data”.
2. Modification of B, 1B Page Data
If the B, 1B page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the B page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1B page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1B page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B, 1B Page data:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
3. B Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
Page Data”).
Table. 5-1-4.
4. 1B Page Table
Note1:
When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
Page Data”).
Address
00 to 01
02
03 to 16
17
18 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 5-1-5.
Address
00 to E0
E1
E2 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Page of 127
Display