2-6
1
FFC-236 flexible
flat cable (50P)
2
DP-74 harness
(10P)
4
Three tapping
screws (B2
×
5)
3
FFC-256
flexible flat cable (4P)
6
B/W EVF block assembly
< 2.5 INCH LCD MODEL >
< 3.0/3.5 INCH LCD MODEL WITH B/W EVF >
1
FFC-236 flexible
flat cable (50P)
3
Three tapping
screws (B2
×
5)
4
Remove
the claws
5
Remove
the claws
1
FFC-236 flexible
flat cable (50P)
2
DP-75 harness
(10P)
4
Three tapping
screws (B2
×
5)
3
FFC-256
flexible flat cable (4P)
6
B/W EVF block assembly
5
Remove
the claws
< 3.0 INCH LCD MODEL WITH COLOR EVF >
1
FFC-236 flexible
flat cable (50P)
2
DP-75 harness
(10P)
4
Three tapping
screws (B2
×
5)
6
Color EVF block assembly
5
Remove
the claws
2
FP-47 flexible board (20P)
3
FP-47 flexible board (20P)
5
Color EVF block assembly
< TR MODEL >
2-6. EVF BLOCK ASSEMBLY
Refer to page 2-7 for disassembly of VF-129 board (B/W EVF).
Refer to page 2-8 for disassembly of VF-126 board (Color EVF).
Refer to page 2-8 for disassembly of VF-126 board (Color EVF).
2-7
VC-213
Tilt lock (93)
1
Screw
2
Slide the button in the
direction of the arrow
a
.
a
b
c
AC POWER
ADAPTOR
ADAPTOR
FP-77 flexible board (22P)
Cabinet (R) assembly
AC IN
LANC jack
DC IN
Adjustment remote
commander (RM-95)
commander (RM-95)
CPC-13 jig
(J-6082-443-A)
(J-6082-443-A)
CPC-13 jig
@¡
CRT socket (4P)
@¢
CRT
@£
Anode cable (1P)
Do not pull the cable,
but remove it in the vertical
direction.
but remove it in the vertical
direction.
@™
Remove the connector
cover with a flat head (–)
screwdriver.
screwdriver.
@º
CRT DT connector (4P)
[How to remove the CRT unit]
FFC-236 flexible
flat cable (50P)
flat cable (50P)
DP-74 harness (10P) (2.5 INCH LCD MODEL)
DP-75 harness (10P) (3.0/3.5 INCH LCD MODEL)
4
Finder (S) assembly
!™
Two tapping
screws (B2
×
5)
!§
Tapping
screw (B2
×
5)
!¶
EVF tally
!∞
EVF cabinet (upper B) (95)
assembly
!¢
EVF cabinet (lower B) (95)
!¡
Tapping screw (B2
×
5)
8
FFC-256
flexible flat cable (4P)
!£
FFC-256
flexible flat cable (4P)
FFC-256 flexible flat cable (4P)
9
VF base(B)(95)
!º
3
Rotate it in the direction of
the arrow
b
and remove it
in the direction of the arrow
c
.
7
Remove
the claw
6
Two screws
(M2
×
3)
5
Harness guide
!ª
CRT assembly
CRT assembly
!•
VF-129 board
VF-129 board
[B/W EVF CHECK SERVICE POSITION]
Panel (N) (front) assembly
Note: the TR models do not have the harness
(DP-74 or DP-75)
(DP-74 or DP-75)
Insulater
side
side
2-7. VF-129 BOARD (B/W EVF MODEL)
2-8
VC-213
1
Harness guide
Claws
Claws
Claws
3
VF base (C) (95)
5
Slide fixed base (C)
6
Two screws (M2
×
3)
lock ace, p2
8
Remove the claw
!º
Slide base (C) (95)
assembly
9
FP-47 flexible board
!¶
FP-47 flexible
board
!¡
!£
Two tapping
screws (B2
×
5)
!∞
Two tapping
screws (B2
×
5)
!¢
EVF cabinet
(rear C) (95)
!•
EVF cabinet
(lower C) (95)
!ª
@º
Claws
@™
Claws
@£
Board holder
@¡
VF-126 board
VF-126 board
VF-126 board
@¢
VF-126 board
@∞
!§
EVF cabinet (upper C) (95)
4
Remove the slide fixed base (C)
by sliding it in the arrow direction
7
Remove the harness
retainer from FP-47
flexible board
flexible board
2
Screw (M2
×
3)
lock ace, p2
FP-47 flexible board
[COLOR EVF CHECK SERVICE POSITION]
AC POWER
ADAPTOR
ADAPTOR
FP-77 flexible board (22P)
Cabinet (R) assembly
AC IN
LANC jack
DC IN
Adjustment remote
commander (RM-95)
commander (RM-95)
CPC-13 jig
(J-6082-443-A)
(J-6082-443-A)
CPC-13 jig
FFC-236 flexible
flat cable (50P)
flat cable (50P)
Panel (N) (front) assembly
VF lens assembly
!™
Turn the lever
in the direction
of the arrow.
of the arrow.
DP-75 harness (10P)
Note: the TR models do not have
the harness (DP-75)
the harness (DP-75)
Insulater
side
side
2-8. VF-126 BOARD (COLOR EVF MODEL)
2-9
VC-213
Board
Board
VC-213
Board
Board
LANC jack
5
Screw (M2
×
3)
6
Screw
(M2
×
3)
7
Screw (M2
×
3)
!º
Flexible board (from LENS block) (24P)
Flexible board
(from LENS block) (24P)
(from LENS block) (24P)
!¡
LENS block
1
FFC-236 flexible flat cable (50P)
AC POWER
ADAPTOR
ADAPTOR
AC IN
DC IN
CPC-13 jig
Adjustment remote
commander (RM-95)
commander (RM-95)
4
FP-54 flexible board (16P)
8
FP-45 flexible board (8P)
9
Ferrite bead
CPC-13 jig
(J-6082-443-A)
(J-6082-443-A)
FP-77 flexible board
(22P)
(22P)
Extension cable
(J-6082-357-A) (16P)
(J-6082-357-A) (16P)
LENS block
Base
(Fix the lens block using a vise or the like.)
(Fix the lens block using a vise or the like.)
Cabinet (R) assembly
3
Cabinet (R) assembly
FFC-236 flexible
flat cable (50P)
flat cable (50P)
Insulater
side
side
Panel (N) (front) assembly
2
DP-74 harness (10P) (2.5 INCH LCD MODEL)
DP-75 harness (10P) (3.0/3.5 INCH LCD MODEL)
Note
DP-74 harness (10P) (2.5 INCH LCD MODEL)
DP-75 harness (10P) (3.0/3.5 INCH LCD MODEL)
DP-75 harness (10P) (3.0/3.5 INCH LCD MODEL)
Note
Note: the TR models do not have
the harness (DP-74 or DP-75)
shown by Note.
the harness (DP-74 or DP-75)
shown by Note.
Note: the TR models do not have
the harness (DP-74 or DP-75)
shown by Note.
the harness (DP-74 or DP-75)
shown by Note.
[LENS BLOCK CHECK SERVICE POSITION]
2-9. LENS BLOCK