DOWNLOAD Sony DCR-PC53E / DCR-PC55 / DCR-PC55E (serv.man4) Service Manual ↓ Size: 802.13 KB | Pages: 61 in PDF or view online for FREE

Model
DCR-PC53E DCR-PC55 DCR-PC55E (serv.man4)
Pages
61
Size
802.13 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc53e-dcr-pc55-dcr-pc55e-sm4.pdf
Date

Sony DCR-PC53E / DCR-PC55 / DCR-PC55E (serv.man4) Service Manual ▷ View online

6-27
DCR-PC53E/PC55/PC55E
9. Picture Frame Setting
Subject
Color bar chart
(Color reproduction adjustment frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Measurement Point
Video terminal of AUDIO/VIDEO
jack
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, E=F
Note1: The following adjustments should be carried out upon completion
of “Flange back adjustment” and “Optical Axis Adjustment”.
Note2: The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
DIGITAL ZOOM (Menu setting) .................................... OFF
3)
STEADY SHOT (Menu setting) ...................................... OFF
Setting method:
1)
Select page: 6, address: 48, and set data: 02.
2)
Adjust the zoom and the camera direction, and set to the
specified position.
3)
Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “Color reproduction adjustment frame”.
Processing after Completing Camera System Adjustments:
After completing the camera system adjustments, release the data
settings.
1)
Select page: 6, address: 48, and set data: 00.
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-10.
2. Vertical period
Fig. 6-1-11.
Check on the monitor TV (Underscanned mode)
Fig. 6-1-12.
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
6-28
DCR-PC53E/PC55/PC55E
10. Color Reproduction Adjustment
Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment frame)
Measurement Point
Video terminal of AUDIO/VIDEO
jack
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
33, 35, 3A, 3B
Specified Value
All color luminance points should settle
within each color reproduction frame.
Note1: This adjustment should be carried out upon completion of “Flange
back adjustment” and “Optical Axis Adjustment”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: NTSC model : DCR-PC55
PAL model
: DCR-PC53E/PC55E
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
DIGITAL ZOOM (Menu setting) .................................... OFF
3)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 48, and set data: 02.
3)
Select page: 6, address: 9D, set the following data, and press
the PAUSE button.
87 (NTSC), 8A (PAL)
4)
Select page: 6, address: 01, set data: 3D, and press the PAUSE
button.
5)
Select page: F, address: 80, set the following data, and press
the PAUSE button.
77 (NTSC), F7 (PAL)
6)
Adjust the GAIN and PHASE of the vectorscope, and adjust
the burst luminance point to the burst position of the color
reproduction frame.
7)
Change the data of page: F, address: 33, 35, 3A and 3B, and
settle each color luminance point in each color reproduction
frame.
Note: Be sure to press the PAUSE button of the adjustment remote
commander before changing the addresses. If not, the new data
will not be written to the memory.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 6, address: 48, and set data: 00.
3)
Select page: 6, address: 9D, and set data: 00.
4)
Select page: 0, address: 01, and set data: 00.
Burst position
For NTSC model
Burst position
For PAL model
Fig. 6-1-13.
6-29
DCR-PC53E/PC55/PC55E
11. Auto White Balance Standard Data Input
Adjust the white balance reference at 3200K.
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
2A to 2D
Note1: This adjustment should be carried out upon completion of “Flange
back adjustment”,  “Optical Axis Adjustment” and “Color
reproduction adjustment”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
DIGITAL ZOOM (Menu setting) .................................... OFF
3)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
02
Set the data.
3
Wait for 2 sec.
4
6
01
11
Set the data, and press PAUSE
button.
5
6
01
0B
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note4)
Note4: The adjustment data will be automatically input to page: F, address:
2A to 2D.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
0
01
00
Set the data.
12. LV Standard Data Input
And adjust the normal coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1A, 1B
Specified Value
0FB0 to 1050
Note1: This adjustment should be carried out upon completion of “Flange
back adjustment”, “Optical Axis Adjustment”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
DIGITAL ZOOM (Menu setting) .................................... OFF
3)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
02
Set the data.
3
6
01
0D
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note5)
5
0
03
1E
Set the data.
6
1
Check that the display data
(Note5) satisfies the specified
value.
Note5: The adjustment data will be automatically input to page: F, address:
1A, 1B.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
0
03
00
Set the data.
4
0
01
00
Set the data.
6-30
DCR-PC53E/PC55/PC55E
13. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
2E to 31, 3E to 41
Note1: This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: NTSC model : DCR-PC55
PAL model
: DCR-PC53E/PC55E
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
DIGITAL ZOOM (Menu setting) .................................... OFF
3)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the lens.
2
0
01
01
Set the data.
3
6
48
02
Set the data.
4
F
3E
2A
Set the data, and press PAUSE
button.
5
F
3F
Set the following data, and press
PAUSE button.
48 (NTSC), 98 (PAL)
6
F
40
5B
Set the data, and press PAUSE
button.
7
F
41
Set the following data, and press
PAUSE button.
C0 (NTSC), 80 (PAL)
8
6
01
83
Set the data, and press PAUSE
button.
9
6
01
81
Set the data, and press PAUSE
button.
10
6
02
Check that the data changes to
“01”. (Note5)
Note5: The adjustment data will be automatically input to page: F, address:
2E to 31.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
0
01
00
Set the data.
4
Perform “White Balance Check”.
Page of 61
Display

Click on the first or last page to see other DCR-PC53E / DCR-PC55 / DCR-PC55E (serv.man4) service manuals if exist.