6-11
DCR-PC53E/PC55/PC55E
1-2-2.
INITIALIZATION OF 8, C, 18, 1C PAGE DATA
Note: When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 18, 1C page data, select page: 0, address:
10, and set data: 01, then select 8 or C page. The 18 or 1C page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 8, C, 18, 1C Page Data
Note1: If “Initializing the 8, C, 18, 1C Page Data” is performed, all data
of the 8 page, C page, 18 page and 1C page will be initialized. (It
is impossible to initialize a single page.)
Note2: If the 8, C, 18, 1C page data has been initialized, following
adjustments need to be performed again.
1) Modification of 8, C, 18, 1C page data
2) LCD system adjustments
3) Serial No. input
4) Servo and RF system adjustments
5) Video system adjustments
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
18
Adjusting Address
00 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C,
18, 1C Page Data”.
2. Modification of 8, C, 18, 1C Page Data
If the 8, C, 18, 1C page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 18, 1C page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 1C page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C, 18, 1C Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
3. 8 Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”.)
Address
00 to 18
19
1A to 29
2A
2B to 41
42
43
44
45
46 to 4C
4D
4E to 79
7A
7B
7C to 81
82
83
84
85
86
87
88
89
8A to 8D
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
6-12
DCR-PC53E/PC55/PC55E
Table. 6-1-7.
4. C Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”.)
Address
8E
8F
90 to 93
94
95 to 99
9A
9B to AB
AC
AD to B2
B3
B4 to B5
B6
B7
B8
B9
BA
BB
BC to BD
BE
BF
C0 to C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE to D6
D7
D8 to DF
E0
E1
E2
E3
E4
E5
E6
E7
E8 to EF
F0
F1
F2 to F9
FA
FB
FC to FF
Remark
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Initial value
NTSC PAL
Address
Remark
Initial value
00 to 0F
10
11
12
13
14 to 15
16
17 to 24
25
26
27
28 to 3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49 to 4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A to 5C
5D
5E
5F
60 to 61
62
63
64 to 66
67
68
69 to 6A
EE
00
00
00
E0
80
54
3D
80
80
74
90
68
CD
EE
00
00
00
E0
81
5C
43
80
80
74
90
68
CD
Switching position adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out chroma level adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
VCO adj. (LCD)
V COM adj. (LCD)
Fixed data-2
Fixed data-1
Fixed data-2
Transmissive mode white balance
adj. (LCD)
Contrast adj. (LCD)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
6-13
DCR-PC53E/PC55/PC55E
5. 18 Page Table
Note1: When reading or writing the 18 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”.)
Table. 6-1-9.
Initial value
NTSC PAL
Address
Remark
Initial value
6B
6C to 74
75
76 to 78
79
7A
7B
7C
7D
7E
7F
80
81
82
83 to 90
91
92
93
94
95
96
97 to A0
A1
A2
A3
A4
A5 to A8
A9
AA
AB
AC
AD to B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB to CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5 to DD
DE
DF
82
80
82
80
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Reflective mode white balance adj.
(LCD)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Initial value
NTSC PAL
Address
Remark
Initial value
E0
E1
E2
E3
E4
E5
E6
E7
E8 to ED
EE
EF to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Serial No. input
Fixed data-1
Fixed data-2
Fixed data-1
Emergency memory address
(Mechanism section)
Table. 6-1-8.
Address
00
01
02 to D7
D8
D9 to DC
DD
DE
DF
E0
E1 to F1
F2
F3 to F6
F7
F8 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
6-14
DCR-PC53E/PC55/PC55E
6. 1C Page Table
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”.)
Table. 6-1-10.
00 to B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9 to D4
D5
D6 to E5
E6
E7
E8
E9
EA
EB
EC
ED to EE
EF
F0
F1 to F5
F6
F7
F8
F9
F9 to FF
00
00
00
00
00
80
00
00
00
00
00
00
00
00
00
00
80
00
00
00
00
00
Fixed data-1
Error rate check
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Address
Remark
Initial value
Page of 61
Display

Click on the first or last page to see other DCR-PC53E / DCR-PC55 / DCR-PC55E (serv.man4) service manuals if exist.